33
ENGLISH
USER INSTRUCTIONS
fig. 1
fig. 2
fig. 3
The display reads the
POSSIBLE STATES
described below:
- OFF STATE
The fireplace is shutting off or is off in response to
operation of the remote control’s ON/OFF key or an
external contact (crono, phone dialler)
The display shows the current time, room temperature
and the status in relation to which the fireplace is OFF.
The fireplace is OFF :
in response manual intervention (fig. 1)
due to power failure (fig. 2)
shut off by Crono mode (fig. 3)
From the OFF page, press the ON/OFF button for 3
seconds to go to the ON page.
Pressing the +/- keys has no effect.
Pressing the M key displays the menu.
- ON STATE
The fireplace is ON.
The display shows (figure 4)
1. the current time
2. the current room temperature
3. the room temperature setting or manual mode
4. the power level (represented by the flames)
5. the fan level (represented by the filling in of the
blades)
If timer programming is active, 3 and 4 are replaced by
the day’s timer programming with the current setpoint
at the centre (figure 5) and the temperature displayed
at the top right.
- ALARM STATE
In case of shutdown due to alarm, 4 is replaced by a
message indicating the type of shutdown (figure 6)
- STAND BY STATE
Situation in which there is no demand for heating.
If the Stand By function is active, the display shows the
same information as in the ON state, without flame in
the upper left displayed “STB”.
fig. 4
fig. 5
H1
fig. 6
When It Is On, The Fireplace Does Not
Always Have A Flame. The Fireplace Turns
On In Response To The Heating Demand
Setting.