background image

ix 

 
 
 
 

3.

 

If there is more than one item per consignment, a packing list must accompany the shipment. It 
is acceptable to combine the proforma invoice and packing list as long as the contents of each 
carton are clearly numbered and identified on the invoice. 

4.

 

Small items can be shipped prepaid directly to EdgeTech by FedEx, DHL, UPS, Airborne, etc. 

5.

 

If  the  equipment  is  the  property  of  EdgeTech  (formerly  EG&G  Marine  Instruments  Division), 
please insure for full value. 

6.

 

Fax one invoice, packing list, and a copy of the airway bill to EdgeTech upon shipment. 

 

 

Содержание STARMUX III

Страница 1: ...EdgeTech 4 Little Brook Road West Wareham MA 02576 Tel 508 291 0057 Fax 508 291 2491 www EdgeTech com STARMUX III U S E R H A R D W A R E M A N U A L 0016903_REV_B July 2016...

Страница 2: ...and are issued in strict confidence on condition that they not be copied reprinted or disclosed to a third party either wholly or in part without the prior written consent of EdgeTech Any reproduction...

Страница 3: ...tatic electricity Therefore extreme care should be taken when handling them Normal handling precautions involve the use of anti static protection materials and grounding straps for personnel WARNING H...

Страница 4: ...rivers if applicable At times however direct replacements may not exist When this happens EdgeTech will provide the necessary drivers with the replacement part if applicable EdgeTech may also change c...

Страница 5: ...ual is subject to change and should be used for reference only Liability EdgeTech has made every effort to document the STARMUX III in this manual accurately and completely However EdgeTech assumes no...

Страница 6: ...tems have not been misused or abused in any manner nor have repairs been attempted thereon without the approval of EdgeTech Customer Service iii Written notice of the failure within the warranty perio...

Страница 7: ...to the customer New software releases consist of the following Software enhancements that are not on the price list Software fixes and changes Product integration Documentation updates to on line hel...

Страница 8: ...ly only to material being returned from outside the Continental United States Follow them carefully to prevent delays and additional costs 1 All shipments must be accompanied by three copies of your p...

Страница 9: ...the contents of each carton are clearly numbered and identified on the invoice 4 Small items can be shipped prepaid directly to EdgeTech by FedEx DHL UPS Airborne etc 5 If the equipment is the propert...

Страница 10: ...products Therefore we encourage you to contact EdgeTech Customer Service to offer any suggestions or to request technical support NOTE Please have your system Serial Number available when contacting...

Страница 11: ...ations for over 45 years The company has responded to the needs of the scientific Naval and offshore communities by providing equipment such as sub bottom profilers side scan sonar acoustic releases U...

Страница 12: ...vii RETURNED MATERIAL AUTHORIZATION viii CUSTOMER SERVICE x COMPANY BACKGROUND xi TABLE OF CONTENTS xii LIST OF FIGURES xiv LIST OF TABLES xv 1 0 OVERVIEW 1 1 1 1 Applications 1 1 2 0 SPECIFICATIONS...

Страница 13: ...xiii 6 0 TROUBLESHOOTING 6 1...

Страница 14: ...I 0016903_REV_B LIST OF FIGURES Figure 3 1 Front and Back Panels of STARMUX III 3 3 Figure 4 1 STARMUX III Internal Components 4 3 Figure 4 2 STARMUX III Block Diagram 4 4 Figure 4 3 STARMUX III Wirin...

Страница 15: ...xv LIST OF TABLES Table 2 1 STARMUX III Specifications 2 1 Table 6 1 STARMUX III Troubleshooting Guide 6 2...

Страница 16: ......

Страница 17: ...00 2000 DSS or 2000 TVD towfish 1 1 Applications The STARMUX III unit can be used in conjunction with the systems above for the following applications Fisheries research Mine countermeasures Hydrograp...

Страница 18: ......

Страница 19: ...mount Case Construction Aluminum 19 inch rack mount Case Finish Anodized Mounting Standard 19 inch rack with provisions for mounting rack slides not provided Input Power 90 260 VAC 50 60 Hz 1200 watts...

Страница 20: ......

Страница 21: ...and potentially damaging UV rays sunlight Furthermore the unit should be located in close proximity to the topside and in an area where the operator can see the deck crew deploying the towfish for ea...

Страница 22: ...hen connect the unit to the topside processor and any other data sources such as a navigation system With the topside processor and the STARMUX III still powered off connect the tow cable to the tow v...

Страница 23: ...vehicle from a survey power down the topside processor and STARMUX III The unit can then be safely disconnected from the tow vehicle If the next survey is not for an extended period of time EdgeTech...

Страница 24: ......

Страница 25: ...VDC Power Supply PS2 receives AC power from the Power Entry module to generate 12 VDC which is used to power the ADSL Modem 375 VDC Power Supply The 375 VDC Power Supply PS1 receives AC power from th...

Страница 26: ...s The FSIU board inputs 24 VDC on J3 from the PS1 24VDC output to power the digital and analog circuitry The FSIU board also inputs 375 VDC power from PS1 The 375 VDC power is output to the tow vehicl...

Страница 27: ...375 V Power Supply 12 V Power Supply Modem Board FSIU Board Sea Cable Interface Power Entry Module Power Switch Figure 4 1 STARMUX III Internal Components...

Страница 28: ...CESSOR 192 9 0 101 ADSL MODEM 192 9 0 23 ADSL MODEM 192 9 0 22 SEA CABLE INTERFACE FSIC TOPSIDE INTERFACE TOPSIDE TOW VEHICLE COMPUTER ETHERNET ADSL ADSL ETHERNET SEA CABLE ADSL LAN FSIU PCB ADSL Figu...

Страница 29: ...Figure 4 3 STARMUX III Wiring Diagram...

Страница 30: ......

Страница 31: ...MUX III is rigidly build and therefore requires little maintenance Occasionally cleaning its cooling fan may prevent overheating after years of dust build up and extend the life of the unit Beyond thi...

Страница 32: ......

Страница 33: ...fuses for continuity Replace if necessary The indicator is not operating Open the unit and check the indicator LED and wiring The green LAN indicator does not illuminate when the unit is turned on The...

Страница 34: ...R SERVICE for modem settings Modem disconnected internally on digital link Check all connections to the modem are correct per the wiring diagram FIGURE 4 3 Improper settings in DISCOVER if used on ext...

Отзывы: