Transponder Lockout
The transponder lockout time sets the maximum interrogation rate that the beacon can be run at. When
working in high multipath environments, longer transponder lockout times are desirable because they
prevent multiple triggers from a single interrogate. If the Transponder Lockout is set to less than 1 second,
it can interfere with the telemetry readings.
3.1.3
4380 Serial Port Command Set
The following commands may be employed by the user:
INxx.x
Sets the interrogation frequency to either 16.0, 17.0, 18.0, 19.0, 20.5, or
21.5 KHz.
RESET
Used to prepare the beacon when loading a reply pulse.
LWNAV
Load the navigation reply waveform.
LWTEL
Load the telemetry reply waveform.
TPON / TPOFF
Turns timed pinger mode ON or OFF.
TPIxxx.x
Set the timed pinger rate, 001.0 – 499.0 seconds.
PTON / PTOFF
Turns pressure telemetry ON or OFF. If pressure telemetry is enabled,
auxiliary telemetry is automatically disabled.
ATON / ATOFF
Turns auxiliary telemetry ON or OFF. If auxiliary telemetry is enabled,
pressure telemetry is automatically disabled.
SNSH / SNSL
Sets high or low receiver sensitivity (100 / 200 microvolt)
TATxxx
Sets the turnaround time, (005 – 250) milliseconds.
RLxx.x
Sets the responder lockout time, (00.5 – 20.0) seconds.
TLxx.x
Sets the transponder lock out time, (00.5 – 20.0) seconds.
POWERL
Selects reduced output power.
POWERH
Selects high output power.
BATT
Displays current battery status
SAVE
Saves the changes to the beacons settings. The user must to save any
changes made to the beacons configuration.
?
Queries the beacon causing it to send its configuration settings.