2-3
2.5
Transducer
Mounting:
End cap
Free Beam Pattern:
Hemispherical for Omni-directional
± 30° from vertical for Directional
Tuning: Factory optimized for 21 – 28 KHz.
2.6
Responder Operation
Logic Input Key:
5v TTL input, optically isolated,
Responder Turn
Around Delay:
1 millisecond
Responder mode:
Responder trigger locks out the transponder function for
a period of approximately 25 seconds
Transponder lockout:
User programmable, 0.5 – 20 seconds
Responder Lockout:
User programmable, 0.5 – 20 seconds
2.7
Transponder Operation
Receive Frequency:
16.0, 17.0, 18.0, 19.0, 20.5 & 21.5 KHz user selectable
Minimum Pulse Width:
5 ms
Transponder Turn
Around Time:
5 - 250 milliseconds, user programmable
Multipath Lockout:
0.5 – 20 seconds, user programmable
Input Sensitivity:
100 / 200 microvolt’s RMS, user selectable
2.8
Timed Pinger Operation
Timed pinger rates:
1.0 to 499.9 seconds, user programmable.
Timed pinger accuracy:
0.005% of setting