Using the Refrigerator Thermometer and Alarm 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

OPERATION MODES  

This unit has two operating modes: NORMAL DISPLAY MODE and 
ALARM DISPLAY MODE.  To change from one mode to another press 
the MODE button once.  NORMAL DISPLAY MODE is indicated by the 
MIN (minimum) and MAX (maximum) temperatures.  ALARM DISPLAY 
MODE is indicated by the HI and LO alarm settings.

   

 

SETTING THE HIGH/LOW ALARM 

1. 

Press the MODE button until unit is in the ALARM DISPLAY MODE 
indicated by the HI and LO temperature settings. 

2. 

To set the HIGH temperature alarm limit press the HI button to 
advance the display by °1.  Press and hold to advance by °5.

 

3. 

To set the LOW temperature alarm limit press the LO button to 
advance the display by °1.  Press and hold to advance by °5.

 

 

ALARM 

The unit will sound the alarm in both NORMAL DISPLAY MODE and 
ALARM DISPLAY MODE. 

Slide the ALARM ON/OFF switch to ON to activate the alarm.  

When the current temperature display rises above the HI set point, or falls 
below the LO set point, the alarm will sound for 1 minute and issue a 3 
second repeater beep every minute after, for up to 12 hours.  The alarm 
will continue to sound even if the temperature returns to “in range” 
condition.   

To temporarily silence the alarm press either the HI or LO button 

on the back of the unit.  The unit is still active and the alarm will sound 
again if the temperature goes out of range.  

 

 

OTHER

 

Slide the switch to change from °F or °C.   

 

Slide the switch to change from normal sampling rate (60 seconds) or fast 
sampling rate (10 seconds).   

 

 

 

NOTE

: Make sure the 

battery is installed before 
beginning operation.     

 

Sampling Rate:   
Fast:     10 seconds  
Normal: 60 seconds 

 

 
Temperature Range: 
°F  -58 to 158  
°C  -50 to 70      
 

WARNING

:  The small 

RESET button MUST be 
pressed whenever a 
change is made to °C/°F, 
FAST/NORMAL sampling, 
or the thermometer is 
plugged in or removed.   
 

Use a pointed object to 
push the RESET button on 
the back of the 
thermometer 

RESETTING MIN/MAX 
MEMORIES

:   

1.  To reset both minimum 

and maximum 
memories press 
MEMORY CLEAR 
button. 

 

2.  To reset individual 

memories press either 
the MIN or MAX button 
on the back

 

of unit once.  

The other memory will 
remain unaffected.

 

 

NOTE:

  You must be in 

NORMAL DISPLAY MODE 
to reset the memories.  

 

(BACK VIEW) 

Содержание RP400MED

Страница 1: ...Precision Cooled Refrigerator User s Guide For more information on other great EdgeStar products on the web go to http www edgestar com RP400MED...

Страница 2: ...mits smells or smoke comes out of it and contact customer service Do not remove any part of the casing unless instructed by an authorized technician You should never attempt to repair the unit yoursel...

Страница 3: ...HOOTING 7 TROUBLESHOOTING CONTINUED 8 SPECIFICATIONS 9 First Time Operating Instructions Before use make sure all packaging labels and materials are removed from the unit Be sure to keep track of all...

Страница 4: ...unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for service under your warranty Model Numb...

Страница 5: ...y safety warning or product information labels from your precision refrigerator Free standing installation A free standing installation will allow you to install the precision refrigerator in almost a...

Страница 6: ...d by rotating the plastic sheaths around each of the feet on the bottom of the machine If you find that the surface is not level rotate the feet until the precision refrigerator becomes level You may...

Страница 7: ...ton is pressed Once set the display will revert to Current Temperature Display that shows the current temperature Press the button on the control panel to lower the temperature by 1 degree increments...

Страница 8: ...sound for 1 minute and issue a 3 second repeater beep every minute after for up to 12 hours The alarm will continue to sound even if the temperature returns to in range condition To temporarily silen...

Страница 9: ...on colder settings some frost may build up Additionally the more humid the ambient conditions the more frost may build up Keep the door closed as much as possible and avoid opening the door unnecessa...

Страница 10: ...rosts 4 With a clean cloth wipe down the interior of the unit 5 Reinsert the shelves 6 Reconnect power to the unit TROUBLESHOOTING Before Calling for Help If the unit appears to be malfunctioning read...

Страница 11: ...ertain sounds are normal Read the Normal Sounds section The unit is not level or is touching another appliance Check to make sure that the refrigerator is level and that it is not in contact with anot...

Страница 12: ...120W Color White Refrigerant R134a 2 3 oz Temperature Range 32 50 F Dimensions Height x Width x Depth 33 1 x 19 4 x 23 1 Weight 79 pounds Note Technical data and performance information is provided f...

Страница 13: ...ility and EdgeStar will supply new rebuilt or refurbished parts free of charge EdgeStar may request a defective part be returned in exchange for the replacement part All replacement parts or products...

Страница 14: ...service edgestar com Register your product download owner s manuals access additional troubleshooting resources and obtain more information on other great EdgeStar products on the web at http www edge...

Отзывы: