Manual drainage 

 

When the portable air conditioner is in cooling or dry mode, it will dehumidify the 
air. The water dehumidified from the air will be collected in an internal reservoir. 
This water will be used to help cool the compressor and it will be evaporated and 
exhausted out the exhaust hose. This unit is designed to exhaust most or all 
condensate water collected out of the air, but in very humid conditions, the internal 
reservoir may fill completely. This causes the air conditioner to turn off to avoid 
overflowing the internal reservoir. The portable air conditioner will begin beeping 
and the Run light will begin blinking and/or the display will show the E7 code. Drain 
the unit to return to normal operation. 

 

Drain parts: 

1.

 

Drain (there is a rubber plug inside this hole) 

2.

 

Drain cap 

3.

 

Drain hose 

4.

 

Drain tray 

 

Draining with the drain tray 

1.

 

Make sure the unit is off. 

2.

 

Position the drain tray on the floor beneath the drain. 

3.

 

Unscrew the drain cap from the drain. Remove the rubber plug from the drain. 

4.

 

When the drain tray is almost full, insert the rubber plug back into the drain and 
screw the drain cap back onto the drain. 

 

17

Содержание AP410W

Страница 1: ...1 ...

Страница 2: ...ndicators 11 Buttons 12 Remote control 12 Setting up the remote control 12 Notes 12 Caution 13 Remote control functions 13 Regulating airflow direction 15 Manual drainage 16 Drain parts 16 Draining with the drain tray 16 Direct drainage 17 Maintenance 17 Notes 17 Cleaning the Exterior 17 Cleaning the condenser coils 17 Prefilter and charcoal filter 17 Notes 17 Installing the charcoal filter 18 Cle...

Страница 3: ...l air from escaping 6 Avoid opening doors frequently 7 Note that each additional person in room adds between 100 150 BTU of heat so the more people in a room the more cooling capacity is required 8 Set the portable air conditioner to maximum cooling and high speed airflow when you first start it up and then adjust the unit to a comfortable setting Notes The portable air conditioner must be plugged...

Страница 4: ...9 15 16 h x 21 w x 17 3 8 d Please note that maximum room sizes are under ideal conditions Actual cooling performance may vary Safety precautions 1 Transport the portable air conditioner in an upright position only If the unit is tipped over make sure it stands upright for at least 3 hours prior to turning it on 2 Always place the unit on a level surface 3 In order to cool the hot air from the exh...

Страница 5: ...se the portable air conditioner in the presence of flammable substances or vapors such as alcohol insecticides gas etc 18 Do not use the plug to start or stop the unit 19 Do not yank on the electric cord or place it near a source of heat If the electric cord is damaged it must be replaced by an authorized service agent 20 Always use the control panel to start or stop the portable air conditioner 2...

Страница 6: ...ront view 1 Control panel 2 Adjustable louvers 3 Carry handles 4 Caster wheels Rear view 1 Air inlet 2 Exhaust port 3 Power cord hooks 4 Caster wheels 5 Drain plug a plastic drain cap covers a rubber stopper 6 ...

Страница 7: ...ssories Owner s manual and warranty card Drain hose Exhaust hose Rectangular vent connector Round adapter Drain tray Carbon filter Cap for round adapter Plastic window kit and screws Remote and batteries 7 ...

Страница 8: ...y the exhaust hose must be mounted to the back of the unit 1 Make sure the rectangular vent connector is fitted to one end of the exhaust hose and fit the round adapter to the other end 2 Insert the rectangular vent connector into the exhaust port on the back of the unit 8 ...

Страница 9: ...it to the appropriate size 2 Once you have properly sized the window kit for the window close the window tightly onto the window kit You may need to use screws to hold the window kit in place 3 Position the portable air conditioner near the window extend the exhaust hose as far as you need to and place the end of the exhaust hose which is in the round adapter into the hole in the window kit 4 Matc...

Страница 10: ...apter into the hole from inside the room and mark the screw hole positions on the wall 3 Remove the round adapter from the wall and drill four screw holes in the positions marked 4 Replace the round adapter into the wall and screw it into place 5 Move the portable air conditioner into place near the wall and insert the exhaust hose into the round adapter Twist the exhaust hose into the adapter in ...

Страница 11: ...Try to prevent any kinks or bends in the exhaust hose Kinks or bends may trap exhaust air which can radiate heat into the room or potentially cause the portable air conditioner to shut itself off 3 The exhaust hose supplied with the portable air conditioner has been specifically designed for this air conditioner Do not lengthen the hose or replace it with any other hose 11 ...

Страница 12: ...actory preset to maintain an ambient temperature of 73 F If the ambient temperature is above 73 F the unit will operate in cooling mode If the ambient temperature is equal to or below 73 F the unit will operate in Fan mode 6 COOL Cooling Mode This light is lit when the Cooling mode is operating 7 DRY Dehumidifier Mode This light is lit when the Dehumidifier mode is operating The Dehumidifier mode ...

Страница 13: ...ber of hours appears in the LED display After the number of hours you selected elapses the unit will turn on To turn the unit off using the timer make sure the unit is on and operating as you want it to Press the TIMER button until the desired number of hours appears in the LED display After the number of hours you selected elapses the unit will turn off 6 ON OFF Turns Unit On Off Press this butto...

Страница 14: ...tton increases the thermostat s temperature setting The part of the button decreases the thermostat s temperature setting These adjustments are only used in the Cooling mode 4 Fan speed selection button This button adjusts the fan speed between the high and low settings 5 Sleep function button This button activates or deactivates the Sleep function Press it once to activate the Sleep function and ...

Страница 15: ...hours appears in the remote control Press the Off timer button again to set the portable air conditioner to turn on in that number of hours 8 Power button This button turns the air conditioner on or off 9 Hour button for on off timer As noted above this button adjusts the number of hours to delay the On or Off timer Additionally this button is used to adjust the clock function of the remote contro...

Страница 16: ... the louvers on this portable air conditioner can be adjusted up and down and from right to left To adjust the horizontal louvers gently move them up or down as desired To adjust the vertical louvers move the handle at the bottom of the louvers 16 ...

Страница 17: ...s the air conditioner to turn off to avoid overflowing the internal reservoir The portable air conditioner will begin beeping and the Run light will begin blinking and or the display will show the E7 code Drain the unit to return to normal operation Drain parts 1 Drain there is a rubber plug inside this hole 2 Drain cap 3 Drain hose 4 Drain tray Draining with the drain tray 1 Make sure the unit is...

Страница 18: ...air intake on the side of the unit This will help clean household dust out of the condenser coils and allow the unit to run as efficiently as possible Prefilter and charcoal filter Notes To keep dust from clogging the unit never use the portable air conditioner without the filter The prefilter on the back of the unit collects dust contained in the air It must be cleaned periodically to keep the po...

Страница 19: ...prefilter 3 If the prefilter needs more thorough cleaning remove the charcoal filter follow the instructions for Installing the charcoal filter but remove the charcoal filter instead 4 Scrub the prefilter gently in warm water Do not use water warmer than 104 or soapy water 5 Allow the prefilter to dry completely 6 Reinstall the charcoal filter into the filter frame 7 Replace the filter frame into ...

Страница 20: ...he unit is too close to a wall or some other obstacle The unit should be at least 20 away from walls and other obstacles Move the unit The unit is covered The unit will overheat if the air intake or exhaust ports are obstructed Remove the obstruction The Timer off function was activated Press the power button to turn the unit back on The air conditioner starts and then cuts out The room temperatur...

Страница 21: ...pple and drain plug The unit is leaking The unit is not on a level surface Make sure the unit is on a level surface The air conditioner is too loud The unit is positioned on a hard uneven floor and is vibrating Move the unit onto a level carpeted surface The Run LED is blinking and the air conditioner is beeping The internal water reservoir is full Drain the water reservoir The LED display seems t...

Страница 22: ... faults in the power supply cord Before use follow the Plug Testing Instructions to ensure that the LCDI circuit is functioning properly Plug Testing Instructions 1 Press Test Button Unit should trip 2 Press Reset Button firmly DO NOT USE IF THE ABOVE TEST FAILS Do not use the TEST and RESET buttons as an on off switch They are only meant to be used to periodically check the LCDI plug CALL CUSTOME...

Страница 23: ...he product or to instruct in proper usage of the product Damages or operating problems resulting from abuse operation outside environmental specifications uses contrary to instructions provided in the owner s manual accidents vermin fire flood improper installation unauthorized service acts of God unauthorized installation or modification or commercial use are excluded from warranty coverage This ...

Страница 24: ... the place of purchase THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT ANY IMPLIED WARRANTY IS REQUIRED BY LAW IT IS LIMITED IN DURATION TO THE EXPRESS WARRANTY PERIOD ABOVE NEITHER THE MANUFACTURER NOR ITS DISTRIBUTORS SHALL BE LIABLE FOR ANY INCIDENTAL CONSEQUENTIAL IN...

Страница 25: ...25 ...

Отзывы: