EdgeStar Portable Air Conditioner
12
The AP14000HS portable air conditioner can work as a heat pump. It
must be vented for it to expel the cold air out the exhaust.
To operate the unit in heat mode:
1) Make sure the power cord is plugged into a power outlet.
2) Press the Power button.
3) Press the Mode button until the
Heat indicator is selected.
4) Adjust the fan speed and temperature to your desired setting. The
thermostat is adjustable between 61°F - 80°F in one degree increments.
Note: The room temperature remaining below the set temperature is
normal. Whether your desired temperature can actually be reached
depends on the ambient conditions
Fan Only mode is used to circulate the air in your room. No temperature
setting is needed.
To operate the unit in Fan Only mode:
1) Make sure the power cord is plugged into a power outlet.
2) Press the Power button.
3) Press the Mode button until the
Fan Only indicator is selected.
4) Press the Speed button to select the fan speed.
You can choose between
Low,
Medium and
High fan speeds.
The Speed button is used to change the fan speed while in Cooling and
Fan Only modes.
Press the Speed button to select the fan speed.
You can choose between
Low,
Medium and
High fan speeds.
The timer can be used to either turn the unit on or off after a number of
elapsed hours. The timer is adjustable between 1-24 hours in one hour
increments.
How to set the unit to automatically turn on
:
1) Press the Timer button while the unit is powered off. The Timer
indicator will appear on the LCD.
2) Use the Up and Down buttons to set the time (displayed in hours) you
wish to pass before the unit turns on. After the selected time passes, the
unit will automatically turn on.
How to set the unit to automatically turn off
:
1) Press the Timer button while the unit is powered on. The Timer
indicator will appear on the LCD.
2) Use the Up and Down buttons to set the time (displayed in hours) you
wish to pass before the unit turns off. The unit will automatically turn off
after the selected time elapses.
In high humidity situations, the internal water reservoir may fill. The unit
will automatically shut off and the water light will turn on. The
Stop
Indicator will appear on the LCD. Once the water is manually drained, the
unit will operate normally.
Heat Mode (HS Model Only)
Fan Only Mode
Speed
Timer
Water Light
NOTE: Fan Only mode does
not require that the exhaust
hose be attached.
NOTE: To cancel the
timer, press the Timer
button or Power button.