10 

Whether your desired temperature can actually be reached 
depends on the ambient conditions. The room temperature 
remaining above the set temperature is normal. 
 
To activate this function mode, press the mode button until the 
cooling  

 symbol appears on the displays.  When the cooling 

mode is set the compressor will start in approximately three 
minutes.   
 
Set the thermostat by using the Up and Down buttons. The 
thermostat is adjustable between 61°F - 86°F in one degree 
increments. You can switch between Fahrenheit and Celsius by 
pressing the ºC / ºF Button. 
 
During the Dehumidifying mode, the unit will condense water out of 
the air and exhaust it through the exhaust hose. The ambient 
temperature in the room will probably drop by a few degrees while 
using the Dehumidifying mode.   
 
To activate the Dehumidify Mode, press the mode button until the 

dehumidifying 

 symbol appears on the displays.  Please note 

when changing modes there is an approximate three minute 
transition time.   
 
During the Sleep Mode, the air conditioner gradually increases the 
set temperature in cooling mode, decreases the noise level and 
conserves energy.  In Sleep mode the temperature is maintained 
for one hour.  In the next 2 hours the temperature is gradually 
increased by 1°F per hour.  After the second hour the temperature 
remains the same. 
 
To activate the Sleep Mode, press the sleep button (moon) until the 
Sleep   symbol appears on the displays.  The fan speed is set to 
low and cannot be altered.  At any time you can cancel by pressing 
the sleep button (moon) on your remote control. 
 
 
In this mode, the air condition is set to run at the optimum 
comfortable temperature.  When the automatic mode is selected 
the cooling function stops when the temperature is below 74°F.  
The cooling function and low fan speed starts when the 
temperature is between 74°F – 78°F Cooling function and medium 
fan speed starts when the temperature is between 78°F – 81°F.  
Cooling function and high fan speed starts when temperature is 
above 81°F.  To activate the function mode, press the MODE 

button on the remote control until the Automatic 

 symbol 

appears. 

Dehumidifying Mode 

Sleep Mode 

Automatic Mode 

Содержание AP13000W

Страница 1: ...Portable Air Conditioner Owner s Manual For more information on other great EdgeStar products on the web go to http www edgestar com AP13000W...

Страница 2: ...designed for indoor use only Do not use the unit in extremely humid or wet environments Do not spray water and wet the housing or control panel Do not pull the unit by the cord Always turn the unit of...

Страница 3: ...REMOTE CONTROL OVERVIEW 8 INSTALLING THE BATTERIES 9 OPERATING THIS UNIT 9 LCD DISPLAY 9 POWER BUTTON 9 AUTO RESTART 9 FAN MODE ONLY 9 REPLACING THE BATTERIES COOLING MODE 9 DEHUMIDIFYING MODE 10 SLEE...

Страница 4: ...the back of your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for service under your w...

Страница 5: ...ntification Front View Back View Parts Key 1 Control Panel 2 Air Outlet Vent 3 Handle 4 Castors 5 Air Filter Grille Intake 6 Air Outlet Heat Exhaust 7 Air Inlet 8 Power Cord 9 Drain Plug 10 Air Filter...

Страница 6: ...e outdoor exhaust hose outlet at the back of the air conditioner 2 Attach the round connector to the opposite end of the exhaust hose Exhaust Hose Rectangular Connector Adjustable Window Panel Window...

Страница 7: ...stalled on a horizontal or vertical sliding window as shown in the pictures below Attach the window panel to the window panel If the inner width of the window is less than 21 530 mm wide 1 Remove the...

Страница 8: ...e unit towards the window kit installed Leave a space at least 20 inches to the wall Connect your exhaust hose to the window kit installed After you have installed the exhaust hose and window kit you...

Страница 9: ...then the hose by adding additional hoses or attachments or replace it with any other hose Do not lengthen the exhaust hose by adding additional hoses or attachments Warning Longer hoses are not recomm...

Страница 10: ...gh Medium and Low Up and Down Press to increase or decrease the set temperature Timer The timer can be used to either turn the unit on or off after a number of elapsed hours The temperature range for...

Страница 11: ...Sleep Mode on or off 4 Unit switch ON delay setting 5 Turns unit off and off 6 Changes temperature between Celsius and Fahrenheit NOTE Be careful not drop the remote control Do not place the remote co...

Страница 12: ...panel until fan only symbol appears on the displays There are three fan speeds High Fan Speed Medium Fan Speed Low Fan Speed Cooling mode cools and dehumidifies the air If the ambient temperature dro...

Страница 13: ...nute transition time During the Sleep Mode the air conditioner gradually increases the set temperature in cooling mode decreases the noise level and conserves energy In Sleep mode the temperature is m...

Страница 14: ...tch on function press timer button until symbol disappears on the display SETTING SWITCH ON TIMER FROM CONTROL PANEL Switch on the air conditioner select the function mode cooling fan only dehumidifyi...

Страница 15: ...nsure they do not obstruct the air intake Minimize the length of the exhaust hose Make sure the exhaust hose is as straight as possible and avoid kinks or bends Keep curtains blinds or drapes closed d...

Страница 16: ...the filter lightly to remove loose dust and dirt then rinse thoroughly under lukewarm running water below 104 F You may use a mild soap and water solution if needed Allow the pre filter to air dry in...

Страница 17: ...it is on a level surface A foreign object has jammed the fan Remove the object from the fan The floor below the unit is uneven Move the unit to a level surface My air conditioner is making a continuou...

Страница 18: ...oo large Minimize the size of the area to be cooled i e adding a drop ceiling Use more than one unit to cool the area or use a larger unit Open windows and doors Close any open doors and windows Too m...

Страница 19: ...tion of product Portable Air Conditioner Model AP13000W Voltage Frequency AC 115V 60Hz Input Power 960W Current 8 6A BTU 13 000 Color White Coolant Quantity R 410A 11 6oz Timer 12 Hour Dimensions WxHx...

Страница 20: ...nstruct in proper usage of the product Damages or operating problems resulting from misuse abuse operation outside environmental specifications uses contrary to instructions provided in the owner s ma...

Страница 21: ...service edgestar com Register your product download owner s manuals access additional troubleshooting resources and obtain more information on other great EdgeStar products on the web at http www edge...

Отзывы: