Important Safety Information

 

 

Improper handling can cause serious damage to the appliance and/or to the 
user.  
 
This portable air conditioner is not intended for use by children. Children should 
be supervised to ensure that they do not play with this product. 
 

 

Your portable air conditioner is supplied with a Leakage-Current 
Detection and Interruption (LCDI) safety plug. This device provides 
protection to reduce the risk of fire due to arcing faults in the power 
supply cord. Before using your portable air conditioner, follow the 
instructions below to ensure that the LCDI plug is working properly:  
 
1.  Plug the power cord to a grounded outlet. 
2.  Press the TEST button on the LCDI plug. This should trip the 
plug and cut the power to the air conditioner. If the plug does not 
trip and you are able to turn on the unit, please contact EdgeStar 
support. 
 

DO NOT USE YOUR PORTABLE AIR CONDITIONER IF THE TEST FAILS. 

 
Press the RESET button to start using your air conditioner.  
 
Do not use the TEST and RESET buttons as an ON/OFF switch. 

Electrical Safety 

 

This unit is designed for indoor use only. 

 

Do not use the unit in extremely humid or wet environments. 

 

Do not wet the housing or control panel. 

 

Do not pull the unit by the cord. 

 

Always turn the unit off and unplug it from the socket when cleaning. 

 

Unplug the unit if it is not going to be used for a long period of time.  

 

Do not operate the unit with a damaged plug or a loose socket. 

 

Use only the correct power supply with appropriate amperage. 

 

If the power cord is damaged, it must be replaced by the manufacturer, 
a service agent, or qualified technician.  

 

Do not remove any part of the casing unless instructed by an 
authorized technician. 
 

General Safety 

 

This portable air conditioner is not intended to be used by children. 

 

Do not allow children to play with the controls or drop any objects into 
the air outlets or vents.  

 

Do not place objects or let any person sit on top of the unit.  

 

Only use in the upright position on a flat, level surface and provide at 
least 20 inches of clearance from any walls or objects.  

 

Route the power cord carefully to avoid a tripping hazard.  

 

This unit is intended for domestic use only. Do not use the portable air 
conditioner for industrial or commercial use.  Any other use may 
invalidate the warranty. 

RESET

TEST

Содержание AP12005ECO

Страница 1: ...Portable Air Conditioner Owner s Manual For more information on other great EdgeStar products on the web go to http www edgestar com AP12005ECO...

Страница 2: ...This unit is designed for indoor use only Do not use the unit in extremely humid or wet environments Do not wet the housing or control panel Do not pull the unit by the cord Always turn the unit off...

Страница 3: ...NNECTOR TO THE GRATED ADAPTER 8 REMOTE CONTROL OVERVIEW 10 INSTALLING THE BATTERIES 10 REMOTE CONTROL LCD INDICATORS 11 OPERATING THE REMOTE CONTROL 12 POWER 12 AUTO RESTART 12 COOLING MODE 12 DEHUMID...

Страница 4: ...the ratings label on the back of your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for...

Страница 5: ...ar Portable Air Conditioner 2 Parts Identification Back View Front View Air Intake Pre filter Air Intake Exhaust Outlet Power Cord Drain Port Caster Handle Remote Control Indicator Light Button Power...

Страница 6: ...e months or as needed It is necessary to clean the pre filter periodically Follow the steps below to install the carbon filter 1 Pull the handle on the pre filter straight up CAUTION Never operate the...

Страница 7: ...e power requirements listed on the product label printed on the side or on the back of your portable air conditioner Your window kit can be installed on a horizontal or vertical sliding window as show...

Страница 8: ...ter 1 Insert the round grated adapter through the back grooved side of the window kit plate with hole 2 Secure the grated adapter by fastening the screws from flat side of the window kit plate to the...

Страница 9: ...ill Then slide the window kit plate to fit the width of the window You can use screws to secure the window kit plate from sliding 4 Lower the window to secure the window kit in place You may need to u...

Страница 10: ...hose A B 5 Attach the connectors to the hose A Extend the ends of the exhaust hose B Thread the duct connector on by turning it clockwise until it stops 20 6 Roll the unit towards the window kit Leave...

Страница 11: ...ortable air conditioner and start using it Connecting the duct connector to the unit Connecting the duct connector to the grated adapter 7 Align the slots on the duct connector to the tabs and snap in...

Страница 12: ...ing additional hoses or attachments or replace it with any other hose Do not lengthen the exhaust hose by adding additional hoses or attachments Warning Longer hoses are not recommended Draining the U...

Страница 13: ...e you set Down Decreases the Temperature Timer or Clock settings Clock Used to set the remote control clock Timer Used to enable the timer C F Switches the temperature between Celsius Fahrenheit Up In...

Страница 14: ...Timer is enabled Timer Shows if the On Timer or Off Timer is enabled Mode Indicator Function Automatic The unit will cool dehumidify or heat some models depending on the ambient temperature The mode a...

Страница 15: ...remote control 3 Press the Mode button until the cooling indicator is selected 4 Select the fan speed by using the Speed button 5 Set the thermostat by using the Up and Down buttons The thermostat is...

Страница 16: ...tor is selected The Fan Speed button is used to change the fan speed while in Cooling and Fan Only modes Press the Fan Speed button to select the fan speed The Automatic High Medium or Low indicator c...

Страница 17: ...tton again to set the timer The timed hour indicator will stop blinking The unit will automatically turn off after the selected time elapses Front Panel Lights and Controls Your portable air condition...

Страница 18: ...n cooling mode for 3 or more hours to cool the room before you arrive You may want to operate the unit all day if you live in a warmer climate Minimize the heat sources direct sunlight computers serve...

Страница 19: ...t and dirt then rinse thoroughly under lukewarm running water below 104 F You may use a mild soap and water solution if needed Allow the pre filter to air dry in a cool and shaded place Dry thoroughly...

Страница 20: ...y A defective remote control Contact customer service My air conditioner is making a loud noise The unit is not level Make sure the unit is on a level surface A foreign object has jammed the fan Remov...

Страница 21: ...more than one unit to cool the area or use a larger unit Open windows and doors Close any open doors and windows Too many heat sources Remove or shut off additional heat sources such as radio equipmen...

Страница 22: ...Description of product Portable Air Conditioner Model AP12005ECO Voltage Frequency 115V 60Hz Input Power 900W Current 9 5A Color Silver Coolant R410A Timer 24 Hour Dimensions H x W x D 30 9 x 17 1 x...

Страница 23: ...e product or to instruct in proper usage of the product Damages or operating problems resulting from misuse abuse operation outside environmental specifications uses contrary to instructions provided...

Страница 24: ...l service edgestar com Register your product download owner s manuals access additional troubleshooting resources and obtain more information on other great EdgeStar products on the web at http www ed...

Отзывы: