background image

11 

 

Operation – Using the Control Panel 

 
 

Setting the Temperature 

1. 

Press the ‘Up’ or ‘Down‘ buttons to set the temperature you desire. 

2. 

The display window will show the temperature you set as you press the 'Up' or 
‘Down' buttons.  Otherwise, it will always show the ambient temperature. 

The default temperature of this machine is:  75

F for cooling

 

Note: 

Temperature control only works in cooling and heating modes.

 

Setting the Fan Speed 

1. 

Press the ‘Speed’ button to choose between high or low. The high or low indicator 
will light on. 

2. 

If the unit is in ‘Auto’ mode, it will choose the fan speed automatically according to 
the ambient temperature (the related indicators will light up). While in ‘Auto’ mode 
pressing the ‘Speed’ button will have no effect.  

 

Setting the Timer to Automatically Shut Off the Unit 

While the machine is running, press the ‘Timer’ button to set the number of hours 
you want to wait for the machine to shut off automatically. You are able to set the 
time between 1 to 12 hours by continuing to press the ‘Timer’ button. The timer 
indicator will light on. When the time set has elapsed, the machine will turn off 
automatically. The display window will show the hour(s) you set as you press the 
‘Timer’ button. If the timer is not engaged, the unit will work continuously. 
 

Setting the Timer to Automatically Power-On the Unit 

While the machine is turned off, you can set the machine to power on by pressing 
the ‘Timer’ button, and setting the desired time. For example, if you set the timer to 
'2', the unit will automatically turn on after 2 hours. 

 

 

Heating function

1. When using Heat Pump, the ambient warm air is recycled and use to heat the area
    where it is required. 

The Exhaust Pipe must be fitted firmly to allow the cold air to 

    be removed outside.

2. Continuous drain is compulsory while the unit is in heat mode. Working range for
    heating function is 41 to 81

o

F. For temperature outside this range. the unit may not work 

    properly.
   

Содержание AP10000HW

Страница 1: ...Portable Air Conditioner Owner s Manual This owner s manual provides instructions on safe installation use and maintenance Please read it carefully and save it for reference AP10000HW...

Страница 2: ...ned for indoor use only 2 Do not use the unit in extremely humid or wet environments 3 Do not wet the housing or control panel 4 Do not pull the unit by the cord 5 Always turn the unit off and unplug...

Страница 3: ...aust Hose Installation 8 Operation Using the Control Panel 10 Using the Remote Control 12 Adjusting the Louvers 12 Maintenance Water Drainage 13 Extending the Drain Tube 14 Cleaning the Unit 15 Prepar...

Страница 4: ...4...

Страница 5: ...eded to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for service under your warranty Model Number ____________...

Страница 6: ...rage 8 Air pre filter 9 Air inlet evaporator 10 Exhaust air outlet 11 Air inlet condenser 12 Water stopper drainage point Accessories 13 Flat adapter for insertion over hose and into window kit 14 Exh...

Страница 7: ...the unit 2 Remove the activated carbon filter from its plastic bag 3 Place the activated carbon filter on the back of the unit 4 Install the pre filter frame to the unit Note Replace the activated ca...

Страница 8: ...ross so that the kit is held securely You may need to adjust the size of the window kit and secure it with screws This technique may also be used for sash windows Note Take care to secure your window...

Страница 9: ...to work less efficiently Improper setup may cause the unit to overheat and shut off Figs 8 9 show the correct position The hose may be extended from 11 to 59 For maximum efficiency use the shortest l...

Страница 10: ...g Between Automatic Cooling Heating or Fan Mode Press the MODE button to select the desired mode automatic cooling heating or fan The indicator of your selected mode comes on Control Panel Parts FIG 1...

Страница 11: ...of hours you want to wait for the machine to shut off automatically You are able to set the time between 1 to 12 hours by continuing to press the Timer button The timer indicator will light on When th...

Страница 12: ...you press any of the buttons 2 Power Button Used to power the unit on or off 3 Mode Button Used to change between auto cooling heating or fan modes 4 Timer Button Used to set the timer function 5 Up B...

Страница 13: ...osition a container a water tray for example underneath the drain hole 3 Remove the drain cap rubber plug from the drain hole and allow the water to drain out 4 When the container is almost full repla...

Страница 14: ...level 2 Flashing Comp Water indicator will not function in this mode of drainage 3 This unit will not shut off when an external drain pan tray is filled 4 If you want to extend the water tube you can...

Страница 15: ...the filter lightly to remove loose dust and dirt then rinse thoroughly under warm running water that is not hotter than 104o F Dry thoroughly before replacing Note The activated carbon filter is not w...

Страница 16: ...room before you arrive You may want to operate the unit all day if you live in a warmer climate 7 Minimize the heat sources direct sunlight computers servers people etc in the room 8 Close all window...

Страница 17: ...t servers etc 5 Run the unit before it is needed For example run the unit in the morning before the area gets hot and continue to run the unit all day long in order to maintain a low temperature 6 Use...

Страница 18: ...15 V 60 Hz Power Ampere Consumption for cooling 830W 7 9 A Power Ampere Consumption for heating 920W 8 2 A Maximum Dehumidifying Capacity 50 pints day Refrigerant R22 15 2 OZ Fan speeds 2 High and Low...

Страница 19: ...ail in basis to EdgeStar s authorized repair facility during the first 90 days from the date of original purchase All defective product components covered by this warranty will be repaired or replaced...