AP Chassis

The AP includes its own bracket kit for mounting the unit to a 1.5 to 6 inch diameter 
pole or part of a radio mast or tower structure. 

Before continuing with AP installation, first review the general guidelines and 
requirements in this chapter.

This chapter includes these sections:

“General Installation Guidelines” on page 20

“How to Mount the Unit” on page 22

“How to Connect External Antennas” on page 24

“How to Align Antennas” on page 25

General Installation Guidelines

Be sure to follow the guidelines below when choosing a location.

Caution:

 The planning and installation of the AP requires professional personnel 

that are trained in the installation of radio transmitting equipment. The user is 
responsible for compliance with local regulations concerning items such as 
antenna power, use of lightning arrestors, grounding, and radio mast or tower 
construction. Therefore, it is recommended to consult a professional contractor 
knowledgeable in local radio regulations prior to equipment installation.

Antenna Position

When planning a location for the AP, consider these guidelines:

When installing for an access point service, be sure to place the AP and external 
antennas in a location that can cover the intended service area.

Try and mount the AP as high as possible above any obstructions in the 
coverage area. This is particularly important for point-to-point links.

Be sure there are no other radio antennas within 2 m (6 ft) of the AP.

Place the AP away from power and telephone lines.

Содержание ECWO5110

Страница 1: ...Installation Guide www edge core com ECWO5110 ECWO5110 L 802 11a b g n Outdoor Dual Band Wireless Access Point...

Страница 2: ...Installation Guide ECWO5110 ECWO5110 L Enterprise Access Point 802 11a b g n Outdoor Dual Band Wireless Access Point E072013 AP R01 150200000760A...

Страница 3: ...specific component with relevant specifications and installation procedures An AP overview section is also provided For Users New to APs If you are new to APs it is recommended that you first read al...

Страница 4: ...strator s Guide EWS4502 CLI Command Reference For all safety information and regulatory statements see the following documents Quick Start Guide Safety and Regulatory Information Conventions The follo...

Страница 5: ...tents 14 System Configuration 15 AP Installation Tasks 15 3 AP Chassis 20 General Installation Guidelines 20 Antenna Position 20 Ethernet Cabling 21 Radio Interference 21 Weather Conditions 21 How to...

Страница 6: ...gnments 35 Connection Procedure 36 Grounding the Ethernet Cable 38 6 AP Management 40 Understanding the System Status LEDs 41 How to Connect to the Console Port 42 How to Set an IP Address ECWO5110 L...

Страница 7: ...gure 12 Attach Bracket to AP 23 Figure 13 Mount the AP on the Pole 23 Figure 14 Antenna Connector Covers 24 Figure 15 Connect External Antennas 25 Figure 16 PoE Power Injector 27 Figure 17 Ground Wire...

Страница 8: ...e 2 Power Injector Module Specifications 28 Table 3 Power Injector Module Status LED 28 Table 4 10 100BASE TX MDI and MDI X Port Pinouts 35 Table 5 1000BASE T MDI and MDI X Port Pinouts 36 Table 6 Con...

Страница 9: ...rovide bridge links between remote LANs Housed in a weatherproof enclosure for mounting outdoors the unit includes its own bracket for attaching to a pole radio mast or tower structure The unit is pow...

Страница 10: ...al describes each specific component or related components together with their installation requirements and procedures in each chapter To understand each component in detail refer to the relevant sec...

Страница 11: ...performing unit monitoring and configuration For more information see How to Connect to the Console Port on page 42 RJ 45 PoE Port The RJ 45 port labeled PoE provides a 1000BASE T data and Power over...

Страница 12: ...more information see How to Ground the Unit on page 29 Pole Mounting Bracket The included Mounting Bracket Kit can be used to mount the unit on a 1 5 to 6 inch diameter pole or to part of a radio mas...

Страница 13: ...s 2x2 MIMO for 2 4 and 5 GHz Integrated Antenna 12 dBi 5 GHz panel type horizontal polarization Radio Frequencies 2400 2483 5 MHz 2412 2472 MHz 5745 5825 MHz China 5180 5320 MHz ETSI 5500 5700 MHz ETS...

Страница 14: ...ccess Point Bracket Mounting Kit for pole mounting PoE Power Injector with power cord either US Continental Europe or UK Waterproof RJ 45 port cover Console cable RJ 45 to DB 9 Quick Start Guide Regul...

Страница 15: ...chapter or section by clicking on the link Unpack package and check contents Unpack your AP and check the package contents to be sure you have received all the items Before installing your AP be sure...

Страница 16: ...e outdoor rated straight through Ethernet cable to connect to the RJ 45 port for your network connection Go to the chapter Network Connections For details on connecting a ground wire Go to the section...

Страница 17: ...r injector indoors Connect the power injector to the Ethernet cable a local LAN switch and an AC power source Note that the AP can also be powered by connecting directly to a IEEE 802 3at PoE switch G...

Страница 18: ...on green the Ethernet LED on blinking orange and the wireless interface LEDs on blinking orange Go to the section Understanding the System Status LEDs Figure 9 System LEDs Connect the AC power cord t...

Страница 19: ...to make a few basic configuration changes to the AP so that it is compatible with your network It is suggested to connect to the AP console port to perform this task Go to How to Connect to the Consol...

Страница 20: ...the installation of radio transmitting equipment The user is responsible for compliance with local regulations concerning items such as antenna power use of lightning arrestors grounding and radio ma...

Страница 21: ...el frequency that is furthest away from another signal Weather Conditions When planning outdoor networks you must take into account any extreme weather conditions that are known to affect your locatio...

Страница 22: ...attaches directly to the AP The two parts link together and allow the tilt angle of the unit to be adjusted for antenna alignment How to Pole Mount Perform the following steps to mount the unit to a 1...

Страница 23: ...nting plate to the bracket already fixed to the pole 5 Use the included long bolt to secure the AP to the pole bracket Note that the AP tilt angle may need to be adjusted for antenna alignment Figure...

Страница 24: ...tion Some omnidirectional external antennas attach directly to the N type connectors on the unit Other antennas may include their own mounting brackets and connect to the unit using RF coaxial cables...

Страница 25: ...ill need to accurately align the antenna with another unit in the network to ensure optimum performance Proper antenna alignment is particularly important for long range point to point links Point to...

Страница 26: ...point links To start you can just point the AP s antenna at the central AP unit using binoculars or a compass to set the general direction Then you can adjust the horizontal and vertical position to f...

Страница 27: ...dule is included in the AP package and provides two RJ 45 Ethernet ports one for connecting to the AP DATA POWER OUT and the other for connecting to a local LAN switch DATA IN The DATA IN port uses an...

Страница 28: ...power injector outside with the AP unit Table 2 Power Injector Module Specifications Item Description AC Input 100 240 VAC 50 60 Hz 0 5 A DC Output 48 VDC 0 35 A Output Power 16 8 W maximum DATA IN P...

Страница 29: ...a point on the bracket pole metal grounding plate or directly to an earth termination Make sure that there is a good electrical connection between the ground wire and the grounding point no paint or i...

Страница 30: ...ll lightning protection at the power injector end of the Ethernet cable use a lightning arrestor immediately before the cable enters the building Figure 18 Connecting the Power Injector 1 Connect outd...

Страница 31: ...r injector and the other end into a grounded 3 pin socket AC power source Note For International use you may need to change the AC line cord You must use a line cord set that has been approved for the...

Страница 32: ...ble specifications The AP features one 1000BASE T RJ 45 port as well as wireless interfaces The sections that follow describe the network interfaces This chapter includes these sections Understanding...

Страница 33: ...ents can connect to the 802 11b g n radio interface using the 2 4 GHz band or to the 802 11a n radio using the 5 GHz band The radio and authentication settings for wireless clients can be configured t...

Страница 34: ...point for the cable Determine if conduits bracing or other structures are required for safety or protection of the cable Be sure to ground the outdoor rated Ethernet cable immediately before it enter...

Страница 35: ...E TX MDI and MDI X Port Pinouts Pin MDI Signal Namea a The and signs represent the polarity of the wires that make up each wire pair MDI X Signal Name 1 Transmit Data plus TD 52V power Negative Vport...

Страница 36: ...ve parts the outer screw on cover the screw on cable clamp the inner plastic RJ 45 plug cover the inner rubber cable seal and the rubber port seal Table 5 1000BASE T MDI and MDI X Port Pinouts Pin MDI...

Страница 37: ...hed 4 Crimp a new RJ 45 connector not supplied on the end of the Ethernet cable 5 Push the inner rubber cable seal into the clamp end of the plastic RJ 45 plug cover 6 Connect the RJ 45 plug to the AP...

Страница 38: ...be connected to protective ground earth The grounding point can be either inside the building or immediately at the entry point to the building depending on where a protective ground is available Cau...

Страница 39: ...e RJ 45 Port 39 Figure 24 Outdoor Rated Ethernet Cable Drain Wire 2 Attach a grounding cable to the drain wire and then connect it to protective earth 3 Use weatherproof tape to cover and seal the att...

Страница 40: ...o the ECWO5110 Management Guide The ECWO5110 L supports network management from a EWS4502 wireless access controller through the Control and Provisioning of Wireless Access Points CAPWAP protocol For...

Страница 41: ...LED Figure 26 System Status LEDs LED Condition Status Power On Green The system power is on Blinking Green The system is currently booting up Off System is off no power LAN On Orange Port has a valid...

Страница 42: ...ect to notebooks or other PCs that do not have a DB 9 COM port use a USB to male DB 9 adapter cable not included with the AP The following table describes the pin assignments used in the RJ 45 to DB 9...

Страница 43: ...le to the Console port on the AP 4 Configure the PC s COM port required settings using VT 100 terminal emulator software such as HyperTerminal running on the management PC 5 Log in to the command line...

Страница 44: ...prompt enter cli then press return to access the CLI prompt 4 Use the following command to set the IP address configure interface ethernet ip address IPv4 netmask gateway Example configure interface...

Страница 45: ...e Ethernet cable is plugged in you may have a problem with the power outlet power cord or PoE power injector However if the unit powers off after running for a while check for loose power connections...

Страница 46: ...re that the clients are properly configured on the RADIUS server If authentication is being performed through IEEE 802 1X be sure the wireless users have installed and properly configured 802 1X clien...

Страница 47: ...top bit no parity and 115200 Baud Rate Check that the null modem serial cable conforms to the pin out connections provided in How to Connect to the Console Port on page 42 Reset the Access Point If al...

Страница 48: ...Ethernet RJ 45 port 11 external antennas 12 external antennas mounting 24 G ground points 11 12 grounding Ethernet cable 38 grounding the AP 29 H hardware errors 45 hardware overview 9 hardware specif...

Страница 49: ...dio interfaces connecting 33 radio interference 21 reset AP 47 RJ 45 connection 34 RJ 45 port 11 routing cables 21 S serial port 11 site selection 20 specifications key 13 status LEDs 33 41 system con...

Страница 50: ......

Страница 51: ...ECWO5110 ECWO5110 L E072013 AP R01 150200000760A Declaration of Conformity DoC can be obtained from www edge core com support download declarations certifications...

Отзывы: