Mounting

–  41  –

Figure 10:  Attaching the Brackets

2.

Mount the device in the rack, using four rack-mounting screws (not 
provided). Be sure to secure the lower rack-mounting screws first to 
prevent the brackets being bent by the weight of the switch.

Figure 11:  Installing the Switch in a Rack

Содержание ECS4310-18T

Страница 1: ...Installation Guide www edge core com ECS4310 18T 18 Port Gigabit Smart Switch...

Страница 2: ......

Страница 3: ...INSTALLATION GUIDE ECS4310 18T GIGABIT SMART SWITCH with 16 10 100 1000BASE T RJ 45 Ports and 2 Gigabit SFP Slots ECS4310 18T E082010 CS R01 150200000210A...

Страница 4: ......

Страница 5: ...ce to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expe...

Страница 6: ...ng to EN 55022 Limit class A for harmonic current emission according to EN 61000 3 2 Limitation of voltage fluctuation and flicker in low voltage supply system according to EN 61000 3 3 Immunity Produ...

Страница 7: ...tly at the fiber TX port and fiber cable ends when they are powered on Ne regardez jamais le laser tant qu il est sous tension Ne regardez jamais directement le port TX Transmission fibres optiques et...

Страница 8: ...he socket outlet must be near to the unit and easily accessible You can only remove power from the unit by disconnecting the power cord from the outlet This unit operates under SELV Safety Extra Low V...

Страница 9: ...rd Set U S A and Canada The cord set must be UL approved and CSA certified The minimum specifications for the flexible cord are No 18 AWG not longer than 2 meters or 16 AWG Type SV or SJ 3 conductor T...

Страница 10: ...ortant l appellation Neutre et avec raccordement direct la terre masse Cordon lectrique Il doit tre agr dans le pays d utilisation Etats Unis et Canada Le cordon doit avoir re u l homologation des UL...

Страница 11: ...teeingang haben Die Netzsteckdose mu in der N he des Ger ts und leicht zug nglich sein Die Stromversorgung des Ger ts kann nur durch Herausziehen des Ger tenetzkabels aus der Netzsteckdose unterbroch...

Страница 12: ...erviceable user parts WARNING Installation and removal of the unit must be carried out by qualified personnel only WARNING When connecting this device to a power outlet connect the field ground lead o...

Страница 13: ...cluded electrical components once the product has reached the end of its life MANUFACTURING MATERIALS There are no hazardous nor ozone depleting materials in this product DOCUMENTATION All printed doc...

Страница 14: ...COMPLIANCES AND SAFETY STATEMENTS 14...

Страница 15: ...nventions are used throughout this guide to show information RELATED PUBLICATIONS The following publication gives specific information on how to operate and use the management functions of the switch...

Страница 16: ...ABOUT THIS GUIDE 16 REVISION HISTORY This section summarizes the changes in each revision of this guide AUGUST 2010 REVISION This is the first revision of this guide...

Страница 17: ...26 Description of Hardware 26 RJ 45 Ports 26 SFP Transceiver Slots 27 Port and System Status LEDs 28 Power Supply Socket 30 2 NETWORK PLANNING 31 Introduction to Switching 31 Application Examples 32 C...

Страница 18: ...nes 45 Connecting to PCs Servers Hubs and Switches 46 Network Wiring Connections 47 Fiber Optic SFP Devices 48 Connectivity Rules 50 1000BASE T Cable Requirements 50 1000 Mbps Gigabit Ethernet Collisi...

Страница 19: ...rough Wiring 56 Crossover Wiring 57 1000BASE T Pin Assignments 58 Fiber Standards 59 C SPECIFICATIONS 61 Physical Characteristics 61 Switch Features 63 Management Features 63 Standards 64 Compliances...

Страница 20: ...CONTENTS 20...

Страница 21: ...imum 1000BASE SX Gigabit Ethernet Cable Lengths 50 Table 7 Maximum 1000BASE LX Gigabit Ethernet Cable Length 51 Table 8 Maximum 1000BASE LH Gigabit Ethernet Cable Length 51 Table 9 Maximum Fast Ethern...

Страница 22: ...TABLES 22...

Страница 23: ...35 Figure 9 RJ 45 Connections 38 Figure 10 Attaching the Brackets 41 Figure 11 Installing the Switch in a Rack 41 Figure 12 Attaching the Adhesive Feet 42 Figure 13 Inserting an SFP Transceiver into...

Страница 24: ...FIGURES 24...

Страница 25: ...The ECS4310 18T provides a broad range of powerful features for Layer 2 switching delivering reliability and consistent performance for your network traffic It brings order to poorly performing netwo...

Страница 26: ...e monitoring of network and port status The switch can be managed over the network with a web browser The switch includes a built in network management agent that allows it to be managed in band using...

Страница 27: ...ormation on the recommended standards for fiber optic cabling see 1000 Mbps Gigabit Ethernet Collision Domain on page 50 Table 1 Supported SFP Transceivers Media Standard Cable Diameter microns Wavele...

Страница 28: ...anel for easy viewing are shown below and described in the following tables Figure 3 Port and System LEDs Table 2 RJ 45 Port Status LEDs 1 16 LED Condition Status 1 24 On Flashing Green Port has estab...

Страница 29: ...Mbps network connection Flashing indicates activity On Flashing Amber Port has established a valid 10 100 Mbps network connection Flashing indicates activity Off There is no valid link on the port Ta...

Страница 30: ...TER 1 Introduction Description of Hardware 30 POWER SUPPLY SOCKET There is one power socket on the rear panel of the switch The standard power socket is for the AC power cord Figure 4 Power Supply Soc...

Страница 31: ...ncing congestion server power user or hub can be attached directly to a switched port And by using full duplex mode the bandwidth of the dedicated segment can be doubled to maximize throughput When ne...

Страница 32: ...the near future You can easily build on this basic configuration adding direct full duplex connections to workstations or servers When the time comes for further expansion just connect to another hub...

Страница 33: ...e 18 distinct collision domains the switch can collapse a complex network down into a single efficient bridged node increasing overall bandwidth and throughput In the figure below the 1000BASE T port...

Страница 34: ...BASE SX MMF link can connect to a site up to 550 meters away a 1000BASE LX SMF link up to 10 km and a 1000BASE LH link up to 80 km This allows the switch to serve as a collapsed backbone providing dir...

Страница 35: ...s This provides a more secure and cleaner network environment VLANs can be based on untagged port groups or traffic can be explicitly tagged to identify the VLAN group to which it belongs Untagged VLA...

Страница 36: ...unless it is actually required to solve a problem Otherwise back pressure jamming signals may degrade overall performance for the segment attached to the hub 3 Based on recommended standards the lengt...

Страница 37: ...ace approximately two inches on all sides for proper air flow be accessible for installing cabling and maintaining the devices allow the status LEDs to be clearly visible Make sure twisted pair cable...

Страница 38: ...k Cable type Unshielded twisted pair UTP or shielded twisted pair STP cables with RJ 45 connectors Category 3 or better for 10BASE T Category 5 or better for 100BASE TX and Category 5 5e or 6 for 1000...

Страница 39: ...Gigabit Smart Switch ECS4310 18T Bracket Mounting Kit two rack mounting brackets and eight screws Four adhesive foot pads Power Cord either US Continental Europe or UK Installation and Management Guid...

Страница 40: ...he ambient room temperature check that the rack environment temperature is within the specified operating temperature range Mechanical Loading Do not place any equipment on top of a rack mounted unit...

Страница 41: ...taching the Brackets 2 Mount the device in the rack using four rack mounting screws not provided Be sure to secure the lower rack mounting screws first to prevent the brackets being bent by the weight...

Страница 42: ...he four adhesive feet to the bottom of the first switch Figure 12 Attaching the Adhesive Feet 2 Set the device on a flat surface near an AC power source making sure there are at least two inches of sp...

Страница 43: ...an appropriate SFP transceiver type 2 Insert the transceiver with the optical connector facing outward and the slot connector facing down Note that SFP transceivers are keyed so they can only be inst...

Страница 44: ...f the switch Figure 14 Power Socket 2 Plug the other end of the cable into a grounded 3 pin AC power source 3 Check the front panel LEDs as the device is powered on to be sure the Power LED is lit If...

Страница 45: ...s Use Category 5 5e or 6 cable for 1000BASE T connections Category 5 or better for 100BASE TX connections and Category 3 or better for 10BASE T connections CABLING GUIDELINES The RJ 45 ports on the sw...

Страница 46: ...tlet that is connected to the wiring closet Otherwise attach the other end to an available port on the switch Make sure each twisted pair cable does not exceed 100 meters 328 ft in length 3 As each co...

Страница 47: ...onnections in the wiring closet with this type of equipment follows 1 Attach one end of a patch cable to an available port on the switch and the other end to the patch panel 2 If not already in place...

Страница 48: ...ean tissue or cotton ball moistened with a little ethanol Dirty fiber terminators on fiber optic cables will impair the quality of the light transmitted through the cable and lead to degraded performa...

Страница 49: ...corresponding to the port to be sure that the connection is valid The 1000BASE SX 1000BASE LX 1000BASE LH fiber optic ports operate at 1 Gbps full duplex with auto negotiation of flow control The max...

Страница 50: ...tallations Category 5e enhanced Category 5 or Category 6 cable should be used The Category 5e and 6 specifications include test parameters that are only recommendations for Category 5 Therefore the fi...

Страница 51: ...ft 6 2 miles LC Table 8 Maximum 1000BASE LH Gigabit Ethernet Cable Length Fiber Size Fiber Bandwidth Maximum Cable Length Connector 9 125 micron single mode fiber N A 2 m 80 km 7 ft 49 7 miles LC Tabl...

Страница 52: ...e guidelines Clearly label the opposing ends of each cable Using your building s floor plans draw a map of the location of all network connected equipment For each piece of equipment identify the devi...

Страница 53: ...t clear contact your dealer for assistance Port LED is Off Verify that the switch and attached device are powered on Be sure the cable is plugged into both the switch and corresponding device If the s...

Страница 54: ...as the power cord or network cabling test them in an alternate environment where you are sure that all the other components are functioning properly IN BAND ACCESS You can access the management agent...

Страница 55: ...ite stripes Also an RJ 45 connector must be attached to both ends of the cable The figure below illustrates how the pins on the RJ 45 connector are numbered Be sure to hold the connectors in the same...

Страница 56: ...r end of the cable When using any RJ 45 port on this switch you can use either straight through or crossover cable Note The and signs represent the polarity of the wires that make up each wire pair ST...

Страница 57: ...r crossover cable to connect to any device type You must connect all four wire pairs as shown in the following diagram to support Gigabit Ethernet Figure 20 Crossover Wiring White Orange Stripe Orange...

Страница 58: ...g information is specified in the ANSI TIA EIA TSB 67 standard Additionally cables must also pass test parameters for Return Loss and Equal Level Far End Crosstalk ELFEXT These tests are specified in...

Страница 59: ...mmarized in the following table Table 14 Fiber Standards ITU T Standard Description Application G 651 Multimode Fiber 50 125 micron core Short reach connections in the 1300 nm or 850 nm band G 652 Non...

Страница 60: ...smission in the 1500 to 1600 nm region with low loss in the 1550 nm band G 655 Non Zero Dispersion Shifted Fiber Single mode 9 125 micron core Extended long haul applications Optimized for high power...

Страница 61: ...ASE T RJ 45 100 ohm UTP cable Category 3 or better 100BASE TX RJ 45 100 ohm UTP cable Category 5 or better 1000BASE T RJ 45 100 ohm UTP or STP cable Category 5 5e or 6 Maximum Cable Length 100 m 328 f...

Страница 62: ...x 1 69 inches TEMPERATURE Operating 0 C to 50 C 32 F to 122 F Storage 40 C to 70 C 40 F to 158 F HUMIDITY Operating 10 to 90 non condensing AC INPUT 100 to 240 V 50 60 Hz 0 7A POWER SUPPLY Internal au...

Страница 63: ...63 SWITCH FEATURES FORWARDING MODE Store and forward THROUGHPUT Wire speed FLOW CONTROL Full Duplex IEEE 802 3x Half Duplex Back pressure JUMBO FRAME Supports up to 9K MANAGEMENT FEATURES IN BAND MANA...

Страница 64: ...Aggregation Control Protocol IEEE 802 1D 2004 Spanning Tree Protocol Rapid Spanning Tree Protocol Multiple Spanning Tree Protocol ISO IEC 8802 3 COMPLIANCES EMISSIONS EN55022 CISPR 22 Class A EN 6100...

Страница 65: ...EGOTIATION Signalling method allowing each node to select its optimum operational mode e g speed and duplex mode based on the capabilities of the node to which it is connected BANDWIDTH The difference...

Страница 66: ...HERNET A 100 Mbps network communication system based on Ethernet and the CSMA CD access method FULL DUPLEX Transmission method that allows two network devices to transmit and receive concurrently effe...

Страница 67: ...cifications for 1000BASE Gigabit Ethernet Now incorporated in IEEE 802 3 2008 LAN SEGMENT Separate LAN or collision domain LED Light emitting diode used for monitoring a device or network condition LO...

Страница 68: ...re on separate collision domains or LAN segments TIA Telecommunications Industry Association TRANSMISSION CONTROL PROTOCOL INTERNET PROTOCOL TCP IP Protocol suite that includes TCP as the primary tran...

Страница 69: ...ork nodes that share the same collision domain regardless of their physical location or connection point in the network A VLAN serves as a logical workgroup with no physical barriers allowing users to...

Страница 70: ...GLOSSARY 70...

Страница 71: ...ctivity rules 10 Mbps 51 100 Mbps 51 contents of package 39 cooling problems 54 cord sets international 44 D desktop mounting 42 device connections 45 E electrical interference avoiding 37 equipment c...

Страница 72: ...onnections 45 pinouts 58 RMON 26 rubber foot pads attaching 42 S SFP transceiver slots 28 single mode fiber optic cables 48 site selelction 37 SNMP agent 26 specifications compliances 64 environmental...

Страница 73: ......

Страница 74: ...ECS4310 18T E082010 CS R01 150200000210A...

Отзывы: