Edge-Core ECS4110-28P Скачать руководство пользователя страница 9

–  9  –

1

Switch Description

This chapter includes these sections:

“System Overview” on page 9

“Key Technical Specifications” on page 11

System Overview

The ECS4110-28P is a Gigabit Ethernet Layer 2 switch with  24 10/100/1000BASE-T 
Power-over-Ethernet (PoE) ports, and four Small Form Factor Pluggable (SFP) 
transceiver slots for fiber connectivity. 

The switch also includes an SNMP-based management agent, which provides both 
in-band and out-of-band access for managing the switch.

Power-over-Ethernet

All of the 10/100/1000 Mbps ports on the switch support both the IEEE 802.3af and 
IEEE 802.3at-2009 PoE standards that enable DC power to be supplied to attached 
devices using wires in the connecting Ethernet cable.

Hardware

Components

Each chapter in this manual describes related switch components together with 
their installation requirements and procedures. To understand each component in 
detail, refer to the relevant chapter.

Figure 1:  Front Panel

10/100/1000BASE-T RJ-45 Ports:  

The switch contains 24 10/100/1000BASE-T RJ-45 

ports that support data and PoE links to other devices. 

1

2

3

5

6

4

Port LEDs

System LEDs

Gigabit SFP Slots

RJ-45 Console Port

Mode Button

1000BASE-T RJ-45 PoE Ports

1

4

2

5

3

6

Содержание ECS4110-28P

Страница 1: ...Installation Guide www edge core com ECS4110 28P 28 Port Layer 2 Gigabit Ethernet PoE Switch...

Страница 2: ...Installation Guide ECS4110 28P Gigabit Ethernet PoE Switch Layer 2 Gigabit Ethernet Switch with 24 10 100 1000BASE T RJ 45 PoE Ports and 4 Gigabit SFP Ports E112015 AP R02 150200000928A...

Страница 3: ...this switch effectively and ensure trouble free operation it is recommended that you read each chapter of this guide in sequence while installing the switch The guide includes these chapters Chapter...

Страница 4: ...following conventions are used throughout this guide to show information Note Emphasizes important information or calls your attention to related features or instructions Caution Alerts you to a poten...

Страница 5: ...eral Installation Guidelines 13 Installation Precautions 13 Switch Installation Tasks 14 3 Switch Chassis 15 Rack Mount Guidelines 15 Switch Cooling Requirements 16 Rack Cabinet Cooling 16 How to Inst...

Страница 6: ...ection Records 30 Copper Cabling Guidelines 31 10 100BASE TX Pin Assignments 32 1000BASE T Assignments 32 Power over Ethernet Guidelines 33 Fiber Cabling Guidelines 34 How to Connect to Twisted Pair C...

Страница 7: ...7 Inserting an SFP Transceiver into a Slot 20 Figure 8 AC Power Supply Socket 21 Figure 9 Grounding Terminal 22 Figure 10 AC Power Cord and Power Socket 23 Figure 11 System and Port Status LEDs 25 Fi...

Страница 8: ...EDs 25 Table 6 Console Cable Wiring 27 Table 7 Using the Reset Button 29 Table 8 Maximum Twisted Pair Copper Cable Lengths 31 Table 9 10 100BASE TX MDI and MDI X Port Pinouts 32 Table 10 1000BASE T MD...

Страница 9: ...e 10 100 1000 Mbps ports on the switch support both the IEEE 802 3af and IEEE 802 3at 2009 PoE standards that enable DC power to be supplied to attached devices using wires in the connecting Ethernet...

Страница 10: ...ch monitoring and configuration System LEDs The switch supports indicator LEDs for displaying system status Port LEDs The switch supports indicator LEDs for displaying port status Figure 2 Rear Panel...

Страница 11: ...th 56 Gbps Switching Database 16K MAC address entries LEDs System Power Diag Diagnostic Ports 1 28 Status link activity speed AC Input Power AC 100 240 V 50 60 Hz 6 A Power Consumption 450 W maximum W...

Страница 12: ...After unpacking the switch check the contents to be sure you have received all the components ECS4110 28P Switch Rack Mounting Kit contains two brackets and eight screws Console cable RJ 45 to DB 9 G...

Страница 13: ...nded Verify that the external power requirements for the switch can be met as listed under Power Supply Units on page 27 Installation Precautions Warning This switch uses lasers to transmit signals ov...

Страница 14: ...l the Chassis Be sure to plan you rack installation taking into account switch cooling requirements Switch Chassis on page 15 Ground the Chassis Use the grounding wire to connect to a rack grounding p...

Страница 15: ...er possible secure the rack to the building ceiling or floor particularly if you are located in a region where earthquakes are common Rack Planning When installing equipment in a rack first plan how u...

Страница 16: ...mounting the switch in an enclosed rack or cabinet be sure to check the following guidelines to prevent overheating Make sure that enough cool air can flow into the enclosure for the equipment it con...

Страница 17: ...t the switch follow these steps Caution Installing the switch in a rack requires two people One should position the switch in the rack while the other secures it using the mounting screws 1 Attach the...

Страница 18: ...peat steps 1 to 4 to mount the switches following your rack plan How to Install the Switch on a Desktop or Shelf The switch can be installed on any flat surface such as a desktop or shelf To mount the...

Страница 19: ...hot swappable The switch does not need to be powered off before installing or removing a transceiver Note SFP transceivers are not provided in the switch package To install an SFP transceiver do the...

Страница 20: ...FP Transceiver 20 Figure 7 Inserting an SFP Transceiver into a Slot Note To uninstall a transceiver First disconnect the network cable then pull the tab to remove the transceiver from the slot SFP tra...

Страница 21: ...tch requires power from an external AC power supply that can provide 100 to 240 VAC 50 60 Hz A standard AC power socket is located on the rear panel of the switch The power socket is for the AC power...

Страница 22: ...nsure that there is a good electrical connection to the grounding point on the rack no paint or isolating surface treatment 3 Disconnect all power cables to the switch 4 Attach a 6 AWG stranded copper...

Страница 23: ...Power Socket 2 Insert the plug on the other end of the power cord directly into the AC input socket on the back of the switch Note Your country s AC power outlet standards may not match the power plug...

Страница 24: ...switch includes a management agent that allows you to configure or monitor the switch using its embedded management software To manage the switch you can make a direct connection to the console port o...

Страница 25: ...rnal power operating normally Off No AC power is connected or the internal power supply has failed DIAG Diagnostic On Green The system diagnostic test has completed successfully On Amber System diagno...

Страница 26: ...l A console cable is supplied with the switch for connecting to a PC s RS 232 serial DB 9 DTE COM port Note To connect to notebooks or other PCs that do not have a DB 9 COM port use a USB to male DB 9...

Страница 27: ...cter Size 8 Characters Parity None Stop bit One Data bits 8 Flow control None Figure 13 Console Port Connection Table 6 Console Cable Wiring Switch s RJ 45 Console Port Null Modem PC s 9 Pin DTE Port...

Страница 28: ...ng VT 100 terminal emulator software such as HyperTerminal running on the management PC The switch s default console port settings are 115200 bps 8 data bits 1 stop bit and no parity 4 Log in to the c...

Страница 29: ...tion file Press the Reset button for 6 seconds or more to restart the system software using the factory default settings Refer to the table below for further details Figure 14 Reset Button Table 7 Usi...

Страница 30: ...onnected devices isolate faults and change your topology without need for unnecessary time consumption To best manage the physical implementations of your network follow these guidelines Clearly label...

Страница 31: ...peration Check the following criteria against the current installation of your network Cable type Unshielded twisted pair UTP or shielded twisted pair STP cables with RJ 45 connectors Category 5 5e or...

Страница 32: ...require that all four pairs of wires be connected Note that for 1000BASE T operation all four pairs of wires are used for both transmit and receive RJ 45 pin numbers Table 9 10 100BASE TX MDI and MDI...

Страница 33: ...ximum of 15 4 W simultaneously For each attached PoE compliant device the switch automatically senses the load and dynamically supplies the required power Any PoE compliant device attached to a port c...

Страница 34: ...roper operation when installing the switch into a network make sure that the current fiber cables are suitable for 1000BASE or 100BASE operation Check the following criteria against the current instal...

Страница 35: ...w to Connect to Twisted Pair Copper Ports Follow these steps to connect cables to 1000BASE T RJ 45 twisted pair copper ports 1 Attach one end of a twisted pair cable segment to the device s RJ 45 conn...

Страница 36: ...Laser Class 1 SFP transceiver 1 Remove and keep the fiber port s rubber plug When not connected to a fiber cable the rubber plug should be replaced to protect the optics 2 Check that the fiber termin...

Страница 37: ...he AC power outlet Check the AC power outlet is supplying 110 240 VAC Contact your dealer for assistance DIAG LED is blinking Amber Power cycle the switch to try and clear the condition If the conditi...

Страница 38: ...ning such as the power cord or network cabling test them in an alternate environment where you are sure that all the other components are validated to be functioning properly In Band Access You can ac...

Страница 39: ...nments 26 contents of package 12 cord sets international 23 D diag LED blinking amber 37 failure 37 diagnosing LED indicators 37 E electrical interference avoiding 13 equipment checklist 12 ethernet 3...

Страница 40: ...ort connecting to 35 rubber foot pads attaching 18 S screws for rack mounting 17 SFP port connection procedure 36 installing transceiver 19 site selelction 13 specifications environmental 11 status LE...

Страница 41: ...ECS4110 28P E112015 AP R02 150200000928A The Declaration of Conformity DoC can be obtained from www edge core com support download declarations certifications...

Отзывы: