Edge-Core ECS2000-10P Скачать руководство пользователя страница 53

C

HAPTER

 4

  |  Making Network Connections

Twisted-Pair Devices

–  53  –

2.

If the device is a network card and the switch is in the wiring closet, attach 
the other end of the cable segment to a modular wall outlet that is 
connected to the wiring closet. (See the section “

"Network Wiring 

Connections" on page 53

.”) Otherwise, attach the other end to an available 

port on the switch.

Make sure each twisted pair cable does not exceed 100 meters (328 ft) in 
length. 

3.

As each connection is made, the Link LED (on the switch) corresponding to 
each port will light green or amber to indicate that the connection is valid.

N

ETWORK

 W

IRING

 C

ONNECTIONS

Today, the punch-down block is an integral part of many of the newer equipment 
racks. It is actually part of the patch panel. Instructions for making connections 
in the wiring closet with this type of equipment follows.

1.

Attach one end of a patch cable to an available port on the switch, and the 
other end to the patch panel.

2.

If not already in place, attach one end of a cable segment to the back of the 
patch panel where the punch-down block is located, and the other end to a 
modular wall outlet.

3.

Label the cables to simplify future troubleshooting. See 

"Cable Labeling and 

Connection Records" on page 59

.

Содержание ECS2000-10P

Страница 1: ...Installation Guide www edge core com ECS2000 10P 10 Port Layer 2 Gigabit Ethernet PoE Switch...

Страница 2: ......

Страница 3: ...INSTALLATION GUIDE ECS2000 10P 10 PORT GE POE SWITCH Layer 2 Managed Switch with 8 10 100 1000BASE T PoE Ports and 2 100 1000 SFP Slots ECS2000 10P E082013 KS R04 150200000502A...

Страница 4: ......

Страница 5: ...ruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required...

Страница 6: ...armonic current emission according to EN 61000 3 2 2009 Class A Limitation of voltage fluctuation and flicker in low voltage supply system according to EN 61000 3 3 2008 Immunity Product family standa...

Страница 7: ...directly at the fiber TX port and fiber cable ends when they are powered on Ne regardez jamais le laser tant qu il est sous tension Ne regardez jamais directement le port TX Transmission fibres optiq...

Страница 8: ...he socket outlet must be near to the unit and easily accessible You can only remove power from the unit by disconnecting the power cord from the outlet This unit operates under SELV Safety Extra Low V...

Страница 9: ...rd Set U S A and Canada The cord set must be UL approved and CSA certified The minimum specifications for the flexible cord are No 18 AWG not longer than 2 meters or 16 AWG Type SV or SJ 3 conductor T...

Страница 10: ...ortant l appellation Neutre et avec raccordement direct la terre masse Cordon lectrique Il doit tre agr dans le pays d utilisation Etats Unis et Canada Le cordon doit avoir re u l homologation des UL...

Страница 11: ...teeingang haben Die Netzsteckdose mu in der N he des Ger ts und leicht zug nglich sein Die Stromversorgung des Ger ts kann nur durch Herausziehen des Ger tenetzkabels aus der Netzsteckdose unterbroch...

Страница 12: ...erviceable user parts WARNING Installation and removal of the unit must be carried out by qualified personnel only WARNING When connecting this device to a power outlet connect the field ground lead o...

Страница 13: ...cluded electrical components once the product has reached the end of its life MANUFACTURING MATERIALS There are no hazardous nor ozone depleting materials in this product DOCUMENTATION All printed doc...

Страница 14: ...COMPLIANCES AND SAFETY STATEMENTS 14...

Страница 15: ...and setting up network equipment consequently it assumes a basic working knowledge of LANs Local Area Networks CONVENTIONS The following conventions are used throughout this guide to show information...

Страница 16: ...ide updated with new wall mount information and updated graphics throughout MARCH 2013 REVISION This is the third revision of this guide it corrects some minor printing issues OCTOBER 2012 REVISION Th...

Страница 17: ...ptions 26 Power over Ethernet 26 Description of Hardware 27 10 100 1000BASE T Ports 27 SFP Transciever Slots 27 Port and System LEDs 28 Power Supply Inlet 30 Grounding Point 30 Reset Button 31 2 NETWO...

Страница 18: ...G NETWORK CONNECTIONS 51 Connecting Network Devices 51 Twisted Pair Devices 51 Power over Ethernet Connections 51 Cabling Guidelines 52 Connecting to PCs Servers Hubs and Switches 52 Network Wiring Co...

Страница 19: ...CONTENTS 19 Installation 62 In Band Access 62 B SPECIFICATIONS 63 Physical Characteristics 63 Switch Features 65 Management Features 65 Standards 65 Compliances 66...

Страница 20: ...CONTENTS 20...

Страница 21: ...e Length 57 Table 5 Maximum 1000BASE SX Gigabit Ethernet Cable Lengths 57 Table 6 Maximum 1000BASE LX Gigabit Ethernet Cable Length 58 Table 7 Maximum 1000BASE LH Gigabit Ethernet Cable Length 58 Tabl...

Страница 22: ...TABLES 22...

Страница 23: ...te Connections with Fiber Cable 37 Figure 11 Making VLAN Connections 38 Figure 12 RJ 45 Connector 42 Figure 13 Grounding 44 Figure 14 Attaching the Brackets 45 Figure 15 Installing the Switch in a Rac...

Страница 24: ...FIGURES 24...

Страница 25: ...access for managing the switch Both switches provide a broad range of powerful features for Layer 2 switching delivering reliability and consistent performance for your network traffic It brings order...

Страница 26: ...out the network NETWORK MANAGEMENT OPTIONS With a comprehensive array of LEDs the switch provides at a glance monitoring of network and port status The switch can be managed over the network with a we...

Страница 27: ...straight through cables for all network connections to PCs or servers or to other switches or hubs See 1000BASE T Cable Requirements on page 57 Each of these ports support auto negotiation so the opt...

Страница 28: ...w and described in the following tables Figure 3 Port and System LEDs Table 1 Supported SFP Transceivers Media Standard Fiber Diameter microns Wavelength nm Maximum Distance Maximum distance may vary...

Страница 29: ...SFP Gigabit Ethernet Ports Ports 9 10 Link Activity On Flashing Amber Port has established a valid 10 or 100 Mbps network connection Flashing indicates activity On Flashing Green Port has established...

Страница 30: ...age to your switch it is recommended that you ground the switch to an earth point by attaching a grounding wire not supplied to the grounding point located on the rear panel with a metal screw If loca...

Страница 31: ...r any switch malfunctions such as a hang or non recoverable error you might want to reset the switch to its default configuration by pressing and holding the reset button for more than 10 seconds The...

Страница 32: ...CHAPTER 1 Introduction Description of Hardware 32...

Страница 33: ...experiencing congestion server power user or hub can be attached directly to a switched port And by using full duplex mode the bandwidth of the dedicated segment can be doubled to maximize throughput...

Страница 34: ...can provide direct full duplex connections for up to 10 workstations or servers You can easily build on this basic configuration adding direct full duplex connections to workstations or servers When t...

Страница 35: ...ted device The switch can supply 9 37 W simultaneously to eight PoE devices among the eight Gigabit Ethernet ports or 30 W simultanesously to two connected PoE devices The total power cannot exceed th...

Страница 36: ...an collapse a complex network down into a single efficient bridged node increasing overall bandwidth and throughput In the figure below the 10 100 1000BASE T ports on the switch are providing 1000 Mbp...

Страница 37: ...an connect to a site up to 550 meters away a 1000BASE LX SMF link up to 10 km a 1000BASE LH link up to 80 km and a 100BASE FX SMF link up to 20 km This allows the switch to serve as a collapsed backbo...

Страница 38: ...This provides a more secure and cleaner network environment VLANs can be based on untagged port groups or traffic can be explicitly tagged to identify the VLAN group to which it belongs Untagged VLAN...

Страница 39: ...ually required to solve a problem Otherwise back pressure jamming signals may degrade overall performance for the segment attached to the hub 3 As a general rule the length of fiber optic cable for a...

Страница 40: ...CHAPTER 2 Network Planning Application Notes 40...

Страница 41: ...r air flow be accessible for installing cabling and maintaining the devices allow the status LEDs to be clearly visible Make sure twisted pair cable is always routed away from power lines fluorescent...

Страница 42: ...rk Cable type Unshielded twisted pair UTP or shielded twisted pair STP cables with RJ 45 connectors Category 3 or better for 10BASE T Category 5 or better for 100BASE TX and Category 5 5e or 6 for 100...

Страница 43: ...ur adhesive foot pads Grounding screw Bracket Mounting Kit containing two brackets and eight screws for attaching the brackets to the switch Power Cord This Installation Guide Documentation CD Include...

Страница 44: ...ck that the rack environment temperature is within the specified operating temperature range Physical Characteristics on page 63 Mechanical Loading Do not place any equipment on top of the rack mounte...

Страница 45: ...screws provided in the Bracket Mounting Kit Figure 14 Attaching the Brackets 2 Mount the device in the rack using four rack mounting screws not provided Be sure to secure the lower rack mounting screw...

Страница 46: ...bracket mounting kit Compared with the rack mount the brackets must be rotated 90 degress when attached to the switch 1 Attach the brackets to the device using the screws provided in the bracket moun...

Страница 47: ...first switch Figure 17 Attaching the Adhesive Feet 2 Set the device on a flat surface near an AC power source making sure there are at least two inches of space on all sides for proper air flow 3 If...

Страница 48: ...switch Figure 18 Power Inlet 2 Plug the other end of the cable into a grounded 3 pin AC power source 3 Check the front panel LEDs as the device is powered on to be sure the Power LED is on green If n...

Страница 49: ...lect an appropriate SFP transceiver type 2 Insert the transceiver with the optical connector facing outward and the slot connector facing down Note that SFP transceivers are keyed so they can only be...

Страница 50: ...CHAPTER 3 Installing the Switch Installing an Optional SFP Transceiver 50...

Страница 51: ...OVER ETHERNET CONNECTIONS The switch automatically detects a PoE compliant device by its authenticated PoE signature and senses its required load before turning on DC power to the port This detection...

Страница 52: ...inout configuration so you can use standard straight through twisted pair cables to connect to any other network device PCs servers switches routers or hubs See Appendix B for further information on c...

Страница 53: ...to each port will light green or amber to indicate that the connection is valid NETWORK WIRING CONNECTIONS Today the punch down block is an integral part of many of the newer equipment racks It is act...

Страница 54: ...CHAPTER 4 Making Network Connections Twisted Pair Devices 54 Figure 21 Network Wiring Connections...

Страница 55: ...clean tissue or cotton ball moistened with a little ethanol Dirty fiber terminators on fiber optic cables will impair the quality of the light transmitted through the cable and lead to degraded perfor...

Страница 56: ...o the port to be sure that the connection is valid The 1000BASE SX LX LH fiber optic ports operate at 1 Gbps full duplex The 100BASE FX fiber optic ports operate at 100 Mbps full duplex The maximum le...

Страница 57: ...tallations Category 5e enhanced Category 5 or Category 6 cable should be used The Category 5e and 6 specifications include test parameters that are only recommendations for Category 5 Therefore the fi...

Страница 58: ...m Cable Length Connector 9 125 micron single mode fiber N A 2 m 70 km 7 ft 43 5 miles LC Table 8 Maximum 100BASE FX Cable Length Type Cable Type Max Cable Length Connector 100BASE FX 9 125 micron sing...

Страница 59: ...e guidelines Clearly label the opposing ends of each cable Using your building s floor plans draw a map of the location of all network connected equipment For each piece of equipment identify the devi...

Страница 60: ...CHAPTER 4 Making Network Connections Cable Labeling and Connection Records 60...

Страница 61: ...ctions between the switch the power cord and the wall outlet Contact your dealer for assistance Diag LED is Flashing Amber Power cycle the switch to try and clear the condition If the condition does n...

Страница 62: ...software tools However you must first configure the switch with a valid IP address subnet mask and default gateway If you have trouble establishing a link to the management agent check to see if you...

Страница 63: ...cable Category 5 or better 1000BASE T RJ 45 100 ohm UTP cable Category 5 5e or better Maximum Cable Length 100 m 328 ft Ports 9 10 SFP transceiver slots 100BASE FX 1000BASE SX 1000BASE LX 1000BASE LH...

Страница 64: ...33 x 20 4 x 4 3 cm 12 99 x 8 03 x 1 69 in TEMPERATURE Operating 0 C to 50 C 32 F to 122 F Storage 40 C to 70 C 40 F to 158 F HUMIDITY Operating 10 to 90 non condensing AC INPUT AC 100 240V 50 60Hz 1 7...

Страница 65: ...FLOW CONTROL Full Duplex IEEE 802 3x Half Duplex Back pressure MANAGEMENT FEATURES IN BAND MANAGEMENT Web or SNMP manager STANDARDS IEEE 802 3 2005 Ethernet Fast Ethernet Gigabit Ethernet Full duplex...

Страница 66: ...ations Compliances 66 COMPLIANCES CE MARK EMISSIONS FCC Class A EN 55022 CISPR 22 Class A EN 61000 3 2 3 VCCI Class A IMMUNITY EN 61000 4 2 3 4 5 6 8 11 SAFETY CSA CSA 22 2 No 60950 1 UL60950 1 CB IEC...