Quick Start Guide
–
2
–
Mount the Device in an EIA-310 Rack
1.
For a 300mm-deep rack, use the four front screw holes to attach
each of the brackets to the device with four of the included bracket
screws. (For a 280mm-deep rack, use the four recessed screw
holes.)
2.
Use the screws and cage/clip nuts supplied with the rack to
secure the device in the rack.
Ground the Device
Verify Rack Ground
Ensure the rack is properly grounded and in compliance with
international and local standards. Verify that there is a good electrical
connection to the grounding point on the rack (no paint or isolating
surface treatment).
Attach Grounding Wire
Attach the grounding wire (#14 AWG/1.5 mm
2
, green with yellow stripe)
to the grounding point on the device’s rear panel or side panel. Then
connect the other end of the wire to rack ground.
Connect Power
a. AC Power
Install one or two AC PSUs in the device, if they are not already installed
in the factory. Then connect an external AC power source to the PSUs.
b. DC Power
Install one or two DC PSUs (part number CDR-6011-6M4 only) in the
device, if they are not already installed in the factory.
Connect an external DC power source to the PSUs. Or, connect to a no-
tolerance DC mains supply with a UL/CSA-approved circuit breaker
rated at 16 A.
Warning:
For a safe and reliable installation, use only
the accessories and screws provided with the device. Use
of other accessories and screws could result in damage to
the unit. Any damages incurred by using unapproved
accessories are not covered by the warranty.
Avertissement:
Pour une installation sûre et fiable,
utilisez uniquement les accessoires et les vis fournies avec
l’appareil. L’utilisation d’autres accessoires et vis pourrait
endommager l’appareil. Les dommages causés par
l’utilisation d’accessoires non approuvés ne sont pas
couverts par la garantie.
Caution:
The device must be installed in a restricted-access
location.
Attention:
L’appareil doit être installé dans un emplacement
à accès restreint.
Note:
The device has the Open Network Install Environment
(ONIE) software installer preloaded, but no software image.
Information about compatible software can be found at
www.edge-core.com
.
Note:
The drawings in this document are for illustration only
and may not match your particular model.
1
1
3
Caution:
The earth connection must not be removed unless
all supply connections have been disconnected.
Attention:
Le raccordement à la terre ne doit pas être retiré
sauf si toutes les connexions d’alimentation ont été
débranchées.
2
Rear Panel
Side Panel
3
Installation