background image

Quick Start Guide

–  

2

  –

Mount the Device in an EIA-310 Rack

1.

For a 300mm-deep rack, use the four front screw holes to attach 
each of the brackets to the device with four of the included bracket 
screws. (For a 280mm-deep rack, use the four recessed screw 
holes.)

2.

Use the screws and cage/clip nuts supplied with the rack to 
secure the device in the rack.

Ground the Device

Verify Rack Ground

Ensure the rack is properly grounded and in compliance with 
international and local standards. Verify that there is a good electrical 
connection to the grounding point on the rack (no paint or isolating 
surface treatment).

Attach Grounding Wire

Attach the grounding wire (#14 AWG/1.5 mm

2

, green with yellow stripe) 

to the grounding point on the device’s rear panel or side panel. Then 

connect the other end of the wire to rack ground.

Connect Power

a. AC Power 

Install one or two AC PSUs in the device, if they are not already installed 
in the factory. Then connect an external AC power source to the PSUs. 

b. DC Power 

Install one or two DC PSUs (part number CDR-6011-6M4 only) in the 
device, if they are not already installed in the factory.
Connect an external DC power source to the PSUs. Or, connect to a no-
tolerance DC mains supply with a UL/CSA-approved circuit breaker 
rated at 16 A.

Warning:

 

For a safe and reliable installation, use only 

the accessories and screws provided with the device. Use 

of other accessories and screws could result in damage to 

the unit. Any damages incurred by using unapproved 

accessories are not covered by the warranty.

Avertissement:

 

Pour une installation sûre et fiable, 

utilisez uniquement les accessoires et les vis fournies avec 

l’appareil. L’utilisation d’autres accessoires et vis pourrait 

endommager l’appareil. Les dommages causés par 

l’utilisation d’accessoires non approuvés ne sont pas 

couverts par la garantie.

Caution: 

The device must be installed in a restricted-access 

location.

Attention:

 L’appareil doit être installé dans un emplacement 

à accès restreint.

Note:

 The device has the Open Network Install Environment 

(ONIE) software installer preloaded, but no software image. 

Information about compatible software can be found at 

www.edge-core.com

.

Note:

 The drawings in this document are for illustration only 

and may not match your particular model.

1

1

3

Caution:

 The earth connection must not be removed unless 

all supply connections have been disconnected.

Attention:

 Le raccordement à la terre ne doit pas être retiré 

sauf si toutes les connexions d’alimentation ont été 

débranchées.

2

Rear Panel

Side Panel

3

Installation

Отзывы: