GSM-VAC4+LITE INSTALLER’S MANUAL
OUTPUTS REMOTE CONTROL
You can use outputs remote control on two different ways:
⇒
calling the GSM-VAC4+ LITE and use DTMF commands
⇒
send the SMS command and get back the SMS with outputs status
1.26 OUTPUTS REMOTE CONTROL BY SMS COMMAND
Command ;
ORCX=1;
Sending this command to the GSM-VAC4+ LITE the output X is going ON.
X = output 1-4
Command
;ORCX=0
;
Sending this command to the GSM-VAC4+ LITE the output X is going OFF.
X = output 1-4
When you want to get the return message with the Output status you must press + before the
command. For example:
Command
;+ORCX=1;
The return message will be:
ORCX=(ON)
1.27 OUTPUTS REMOTE CONTROL BY DTMF COMMAND
After the short beep press the DTMF command. Response with 1 beep means that the output is
active (ON) and response with 3 beep means that the output is in inactive (OFF) mode.
11
Output 1 ON (bi-stable) or ON for mono-stable
12
Check the output 1 state (1 beep=ON, 3 beeps=OFF)
10
Output 1 OFF (bi-stable) or ON for mono-stable
20
Output 2 OFF (bi-stable) or ON for mono-stable
21
Output 2 ON (bi-stable)
Use 12, DTMF command to verify the output state. With DTMF command
“00”
you may put all
outputs
OFF
and with command
”01”
all outputs
ON
in the same time.