•  Avoid blocking the opening of the vacuum cleaner while in use.  Turn off and
unplug power cord before removing wedged or caught objects.  Keep clothing,
hair, hands and other body parts away from vacuum opening while in use.

•  Do not use product without a properly installed dust bag.

•  Replace dust bag at regular intervals.  failing to do so will affect the 
product’s performance, and may result in permanent damage.

•  Keep vacuum cleaner level when vacuuming stairs and risers.  make sure
there is sufficient cord length at all times.

•  Use only as described in manual.  Use manufacturer’s recommended  
parts.

•  Do not put any objects into openings.  Do not use with any opening
blocked.  Keep free of dust, lint, hair and anything that may reduce air flow.

•  Turn off all controls before unplugging.

•  Do not use with damaged cord or plug.  if appliance is not working as it
should, has been dropped, damaged, left outdoors, or dropped into water,
return it to BioTech Research for service.

•  This product was built to accommodate 120V.  Using another voltage will
damage product.   See wire and grounding instructions on pg. 4.

Important Safety Instructions cont.

How to Change the Belt

CAUTION:

first, unplug the vacuum cleaner from the
electrical outlet.

1.   Turn the unit over and remove the 

bottom plate.

2.   Remove the brushroll and the worn

or broken belt from the brushroll
pulley and the motor drive shaft.       
(photo 1)

3.   Loop the new belt around the motor

drive shaft and the brushroll.              
(photo 2)

4.   Reinstall the brushroll back into the 

housing. Turn the brushroll by  
hand, making sure the belt is not
twisted and all rotating parts move
smoothly. (photo 3)

5.   Reinstall the bottom plate.

NOTE:

To ensure maximum cleaning effi-

ciency, the belt should be checked regularly to
be sure it is in good condition. Check to see if
the belt is stretched, cracked, or if excessive
slipping has occurred. Replace if needed. 

1

2

3

Содержание EdenPURE Bio SpeedCLEAN

Страница 1: ...se BSCSEH Only 5 95 _______ ___ Attachment Wands 2 pc set BSCPT2 Only 5 95 _______ ___ 2 in 1 Brush Crevice Tool BSCBR Only 5 95 _______ Shipping Handling _______ TOTAL _______ Authorized Replacement Parts Form 7800 Whipple Avenue NW Canton Ohio 44767 To order by phone call toll free 1 800 466 7688 Operator Code EPBSI Monday Friday 6am 3am Saturday 7am Midnight and Sunday 7am 11pm To order online ...

Страница 2: ...arranted for ninety days What is not covered Damage to the vacuum which occurs from neglect abuse alterations accidents misuse or improper maintenance Normal wear items such as belts bulbs cord roller brush and carbon brushes What the warranty provides This warranty provides at no cost to you all labor and parts to keep this vacuum in correct operating condition for the items covered dur ing the w...

Страница 3: ...al instructions How to Reset the Circuit Breaker your vacuum features a circuit breaker to protect the machine against dam age due to a surge in the electrical current Electrical surging can be a result of though not limited to a jammed brush roll for example vacuuming up large items socks etc Should your Bio SpeedCLEAN UV vacuum cleaner experience a jammed brushroll with the circuit breaker tripp...

Страница 4: ...y Information 11 Changing the UV Lamp 1 Use a phillips head screwdriver to remove the 2 screws located on the bottom of the main body See following figure 2 Depress 2 clips on the back of the hood to gently release the hood from the main body 3 gently unplug the UV lamp from the lamp terminal and replace with a new UV lamp power off before replacing the UV lamp and replace with identical type lamp...

Страница 5: ...arry the product by the cord use cord as a handle vacuum over the cord or allow the cord to become wedged in a door Added attention is necessary when using around sharp edges and corners Keep cord away from heated surfaces Unplug the power cord plug before maintenance pulling on the cord may damage the product and lead to injury Always dry one s hands before handling this product to avoid risk of ...

Страница 6: ...ot working as it should has been dropped damaged left outdoors or dropped into water return it to BioTech Research for service This product was built to accommodate 120V Using another voltage will damage product See wire and grounding instructions on pg 4 Important Safety Instructions cont How to Change the Belt CAUTION first unplug the vacuum cleaner from the electrical outlet 1 Turn the unit ove...

Страница 7: ... 13 Attachment wands 14 Brush and crevice tool 15 Attachment hose intake port Operation A plug in the unit the 4 leds will light press the two level speed regulate switch the unit will start to work The power can be regulated Low for tile hard wood floors and rugs and high for carpets B press the UV switch the UV lamp will be lighted and the sterilization function will start C if the dust bag need...

Страница 8: ...il to fit contact a qualified electrician to replace the obsolete outlet Do not attempt to defeat the safety purpose of the polarized plug Assembling the Vacuum IMPORTANT NOTE Under no circumstances should you plug in the vacuum cleaner prior to complete assembly 2 Assemble according to the following figures 3 press the buttons at the dirt entrance of the dust bag then mount the dust bag on the un...

Отзывы: