background image

©2001 Edelbrock Corporation 

Rev. 5/01 

PARTS LIST 

DISASSEMBLY (Continued) 

 

5.   Remove O2 sensor (if applicable) being careful not to destroy or rupture the unit.  

Warning:  Do not clean this unit in any cleaning solvents and do not rupture 

wire

6. Remove the two nuts from hanger bracket.  Remove the two bolts and springs at the 

catalytic converter.  Then unbolt the three bolts at the mid-section of manifold and 

remove lower portion of manifold (B-section). 

7. Remove the bolt that is attached to the engine block in the lower section of manifold.  

Remove bolts from manifold at cylinder head and pull manifold out from top side.   

Note:  Save all factory nuts, bolts and springs to be used during re-assembly. 

ASSEMBLY 

1. Install (a section) of header assembly from top side with gasket and 9 hardened 

washers (supplied in kit), using factory bolts/nuts as applicable.  

2. Install secondary section (B section) to (A section) top half using the three 10mm.  Bolts 

and lock washers with the two crush ring gaskets (all supplied in kit).  Use anti-seize on 

threads.  (The two crush rings should be installed with the seam or split down towards 

B-section). 

3. With donut in place, connect header  to catalytic converter using stock hardware as 

before. 

4. Install O2 sensor “if equipped”.  Use anti-seize on threads of sensor and torque to 30 ft. 

lbs. 

Part Numbers 

Qty. 

PN 

Description 

 

25-9180 

Pro-Flo Header (A Section) 

6642 

25-9191 

Pro-Flo Header (B Section) 

 

22-6852 

Installation Kit 

 

25-9182 

Pro-Flo Header (A Section) 

6742 

25-9192 

Pro-Flo Header (B Section) 

 

22-6852 

Installation Kit 

 

25-9178 

Pro-Flo Header (A Section) 

4742 

25-9193 

Pro-Flo Header (B Section) 

 

22-6852 

Installation Kit 

Edelbrock Corporation 

2700 California Street 

Torrance, CA 90503 

Tech Line:  (800) 416-8628 

E-Mail:  [email protected] 