Print Date 04/01/11 Page 13 of 42 E2165-00MA-04
Status Indications
Four line by 20 character back-lit LCD display with selectable screens
showing output frequency, forward and reverse power and instantaneous
deviation level ; individual system normal status components ; settings of any
optional modules fitted ; comprehensive bargraph and digital readout
metering of analogue levels (including peak hold and kHz/percentage
displays of deviation) ; frequency settings and status of all seven channels.
Red/green/off led indicators of modulation level, system normal status and
mute status.
Red/green pass/fail led indicators of Amplifier Module output forward and
reverse power, heatsink temperature, dc supply current and CPU status.
Local Control
Eight key sealed membrane keypad including : -
main and mode screen dedicated keys, two cursor keys and four soft keys.
Remote Control
and Monitoring
RS232 or TCP/IP (preset internal link setting) using 2400, 4800, 9600 or
19200 Baud asynchronous data (1 start, 8 data, 2 stop, no parity) rate
selectable from front panel. All local control and monitoring is duplicated over
the serial link. RS232 on nine way ’D’ plug, TCP/IP on RJ45 socket.
Basic parallel control/monitoring including a safety interlock and analogue
output voltage levels indicating forward and reverse output power (on 25 way
‘D’ socket). Baseband and RF monitoring BNC outputs on front panel.
Environmental
Ambient Temperature (operating) : -5 to +50 deg.C
Ambient Temperature (storage) : -20 to +70 deg.C
Relative Humidity (operating) : Less than or equal to 95%, non condensing
with the Exciter at a higher temperature than the ambient.
Altitude (operating) : Up to 3000 metres a.s.l.
Mechanical
Width : 483mm (19 in.)
Height : 88mm (2U)
Depth : 520mm
Weight : Approx. 15kg.
Notes depths are intrusion into rack including cabling at the rear.
Power Supply
Single phase input on 10A IEC connector: -
XE150 : 100-260VAC (47-63Hz)
3A at 100V to 1.2A at 260V (at 150W RF output)
Power factor meets EN61500-3-2
Peak inrush current 14A -28A at 100V - 260VAC input
XE300 : 100-260VAC (47-63Hz)
6A at 100V to 2.4A at 260V (at 300W RF output)
Power factor meets EN61500-3-2
Peak inrush current 14A - 28A at 150V - 260VAC input