7. Master/Slave Control

The MASTER functions as a master as long as it’s not in DMX mode (and 
ideally no cable plugged into the DMX INPUT on the unit). It sends a 
signal to the SLAVE through a DMX cable and synchronizes its settings to 
it. Do not use more than 20 lamps or 60m of DMX cable.

The SLAVE units should be set to DMX mode and the address code set to 
“d001” to receive the MASTER’s signal. Only one light can be set as a 
master, but multiple lights can be set as slaves.

8. Cable Connection

A standard XLR connection is used for the DMX 512 protocol:

DMX512 does not include automatic error checking and correction, and so 
is not an appropriate control for hazardous applications, such as 
pyrotechnics or movement of theatrical rigging. False triggering may be 
caused by electromagnetic interference, static electricity discharges, 
improper cable termination, excessively long cables, or poor quality 
cables.

If using 5-pin DMX, please use a 5-pin to 3-pin cable adapter. Details on 
configuration below:

Note:

 In order to avoid failures and 

signal interference, it is recommended 
to connect a 120

Ω

 resistor (1/4W) at the 

end of the DMX connection as shown on 
right. If using 5-pin DMX, please use a 
5-pin to 3-pin cable adapter. Details on 
configuration below:

Содержание LED SUPER PAR

Страница 1: ...LED SUPER PAR USER MANUAL...

Страница 2: ...1 Introduction 2 Safety Information 3 Dimensions and Specifications 4 Main Function 5 Rear Panel Display and Operation 6 Instructions for Manual Programming 7 Master Slave Control 8 Cable Connection...

Страница 3: ...rounds hotels large scale performances drapery uplighting and stage lighting Packing List LED Super Par light User manual Warranty card 2 Safety Information Please consult skilled service technicians...

Страница 4: ...0W Size 140mm deep x 190mm wide x 240mm high Net Weight 1 5 Kg Rated IP20 Lamp Type 7 pc of 5 in 1 High Power 10W LED s Lamp Life 50 000 100 000 hours Lamp Angle 25 45 degrees produces a 5 dia spot of...

Страница 5: ...0 100 2 0 255 Green dimming 0 100 3 0 32 Blue dimming 0 100 4 0 255 Amber dimming 0 100 5 0 255 White dimming 0 100 6 0 255 Master dimmer 7 15 255 Strobe speed 8 72 133 3 color jumping Overrides CH1 7...

Страница 6: ...0 11 Colo Preset colors 0 30 Strb Strobe mode speed 0 15 rL Solid color mode red setting 0 255 gL Solid color mode green setting 0 255 bL Solid color mode blue setting 0 255 aL Solid color mode amber...

Страница 7: ...tness of that color Press ENTER to choose Repeat the process for each color Sample colors Visit the website for more color combinations Color Name Red Green Blue Amber White Red 255 0 0 0 0 Green 0 25...

Страница 8: ...sed for the DMX 512 protocol DMX512 does not include automatic error checking and correction and so is not an appropriate control for hazardous applications such as pyrotechnics or movement of theatri...

Отзывы: