8. Cable Connection

A standard XLR connection is used for the DMX 512 protocol:

Note:

 DMX512 does not include automatic error checking and correction, 

and so is not an appropriate control for hazardous applications, such as 
pyrotechnics or movement of theatrical rigging. False triggering may be 
caused by electromagnetic interference, static electricity discharges, 
improper cable termination, excessively long cables, or poor quality 
cables.

Note:

 In order to avoid failures and 

signal interference, it is recommended 
to connect a 120

Ω

 resistor (1/4W) at the 

end of the DMX connection as shown on 
right. If using 5-pin DMX, please use a 
5-pin to 3-pin cable adapter. Details on 
configuration below: