Edbak ERM100-L Скачать руководство пользователя страница 13

ERM100-L-IM-01

ASSEMBLY

MONTAZ

www.edbakproav.com

13

13.05.2019, ERM100-L-IM-01

Connection

The application works with ZL-RC02 module, which has a built-in Bluetooth 4 module, 

so there is no need to pair the module with a smartphone or tablet. 

The task of the application is to facilitate the management and control of multiple modules and their operation.

Change of name

To change the module name, connect to the selected module. Then press the [CHANGE NAME] button, 
then enter the new device name in the yellow "New device name" field. The name may contain only letters, numbers 
and additional characters "minus" and "underscore". After entering the name, press the [SET] button. 

The device name will be changed and the device will be disconnected and the device will return to the list. 
Then search for the device again.

Pin code

The application remembers individual PIN codes for modules in the database located in the device on which it is running. 
This is needed to automatically select the correct PIN depending on the device to which you are connecting. 

Each change of the PIN code in the device causes a change of the saved PIN code in the database. 

Because the module does not inform the application about whether it has changed the PIN code, 
the application assumes that the password change has been successful and the new PIN code is saved in the database. 

The PIN must be exactly 8 digits.

The yellow field above the [USE PIN] button should contain the current PIN for the connected module. 
If there is no PIN in this field, we can enter it manually and press [USE PIN]. 
This means that from now on the application will use the new PIN for connections. 
The [DOWNLOAD PIN] button can be used to download a PIN saved in the database. 
The read PIN code will be entered into the field, 
but for the application to use the new PIN code, press the [USE PIN] button.

Changing the PIN code

To change the PIN code, make sure that the correct PIN code is entered in the yellow field above the [USE PIN] button. 
Then press the [CHANGE PIN] button. We only provide the new PIN in the form that appeared. After entering the new PIN code, 
press the [SET] button. The PIN will be set and disconnected from the device just like after changing the name.

Walls

The application allows you to group devices into "walls". This makes it easier to filter those needed from all those 

that are currently visible. To assign a device to a selected wall, 

connect to it and then select the correct position from the list of walls. 
If the required position is not there, create it in the wall wizard, 
which is located below the [DOWNLOAD PIN] and [USE PIN] buttons.
After creating a new position, select it from the list of available walls and assign the device to the wall in this way. 
You do not need to perform any additional operations.
You can delete the wall from the database. Performing this action will free all devices assigned to it. From now on, 

they will only be visible when browsing all visible devices.

Navigating

After selecting the device from the list, the module control interface is shown and an attempt is made to connect to it. 
If the connection with the module fails, the application returns to the device list. When establishing a connection, 
the selected buttons are not active. Only after a successful connection is it possible to control and configure the module. 
To move the mechanism, hold the large button with the white triangle. 
The button should be held until the mechanism reaches the required position. 
If the technical conditions make it impossible to maintain communication with the module, 
it will automatically disconnect and return to the list of devices.

Simplified user manual module control application ZL-RC02.

Содержание ERM100-L

Страница 1: ...www edbakproav com ERM100 L ELECTRIC FULL SERVICE VIDEO WALL MOUNT WITH MICRO ADJUSTMENT UCHWYT SCIENNY WYSUWANY ELEKTRYCZNIE Z MIKRORERULACJA ERM100 L IM 01 ...

Страница 2: ...l The terms of the product guarantee are detailed in the guarantee card Ostrzeżenie Przed rozpoczęciem montażu należy uważnie zapoznać się z instrukcją uchwytu oraz ekranu w celu zapewnienia prawidłowego montażu Prace montażowe powinny wykonywać co najmniej dwie osoby posiadające kwalifikacje w zakresie montażu zgodnie z niniejszą instrukcją Firma EDBAK nie bierze odpowiedzial ności za straty mater...

Страница 3: ...www edbakproav com 3 AA 10A 120W 230VAC 12VDC 5 5 x 2 1mm 1x PART LIST LISTA ELEMENTÓW BB 1x CC 1x low voltage dc cable DC 5 5 2 1 socket DC 5 5 2 1 plug x5 straight 0 5mm2 DD 1 for 5 mounts 13 05 2019 ERM100 L IM 01 ...

Страница 4: ...0 4x A04 M8x20 4x A05 fi15 x fi8 4 x 5 4x A06 fi15 x fi8 4 x 10 4x A01 M4x20 4x A02 M5x20 4x PART LIST LISTA ELEMENTÓW www edbakproav com 4 13 05 2019 ERM100 L IM 01 A07 M8 4x A08 M5 4x A09 3mm 1x A10 4mm 1x A11 5mm 1x A12 6mm 1x ...

Страница 5: ...ERM100 L IM 01 B 2x C 1x D 1x DC 5 5 2 1 plug DC 5 5 2 1 socket straight 0 5mm2 2m EE 6x FF 6x 6x80 GG 6x M6 A 1x PART LIST LISTA ELEMENTÓW www edbakproav com 5 13 05 2019 ERM100 L IM 01 ...

Страница 6: ...ERM100 L IM 01 ASSEMBLY MONTAZ www edbakproav com 6 1 13 05 2019 ERM100 L IM 01 2 AA FF EE GG A INSTALLATION TO BRICK OR CONCRETE WALL ...

Страница 7: ...ERM100 L IM 01 ASSEMBLY MONTAZ www edbakproav com 7 13 05 2019 ERM100 L IM 01 3 CHECK THE POSITION OF FRAME EE GG INSTALLATION TO WOOD STUD WALL ...

Страница 8: ...0 L IM 01 ASSEMBLY MONTAZ www edbakproav com 8 13 05 2019 ERM100 L IM 01 4 CHECK THE POSITION OF FRAME MULTIPLE DISPLAY ASSEMBLY WITHOUT SPACERS DISPLAY WIDTH A DISPLAY WIDTH DISPLAY HEIGHT B DISPLAY HEIGHT ...

Страница 9: ...00 L IM 01 ASSEMBLY MONTAZ www edbakproav com 9 13 05 2019 ERM100 L IM 01 5 7 6 MULTIPLE DISPLAYS ASSEMBLY USE OF OPTIONAL SPACERS dedicated spacer B A01 A02 A03 A04 A07 A08 A05 A06 WARNING LOCKING SCREW BB ...

Страница 10: ...ERM100 L IM 01 8 9 10 ASSEMBLY MONTAZ www edbakproav com 10 13 05 2019 ERM100 L IM 01 HORIZONTAL ADJUSTMENT VERTICAL ADJUSTMENT TITLING ADJUSTMENT ...

Страница 11: ...ERM100 L IM 01 11 12 ASSEMBLY MONTAZ www edbakproav com 11 13 05 2019 ERM100 L IM 01 DISPLAY MICRO ADJUSTMENT CONNECTING AND INSTALATION CABLE MANAGEMENT ARM PLUG SOCKET ...

Страница 12: ...ERM100 L IM 01 13 ASSEMBLY MONTAZ www edbakproav com 12 13 05 2019 ERM100 L IM 01 CC DD C ...

Страница 13: ...will be entered into the field but for the application to use the new PIN code press the USE PIN button Changing the PIN code To change the PIN code make sure that the correct PIN code is entered in the yellow field above the USE PIN button Then press the CHANGE PIN button We only provide the new PIN in the form that appeared After entering the new PIN code press the SET button The PIN will be set a...

Отзывы: