Страница 1: ...CO2 1 or 30 Temperature RH Diffusion Data Loggers Models Covered ESCM 16 ESCM 17 ESCM 18 ESCM 19 ESCM 209 ESCM 210 ESCM 08 CC ...
Страница 2: ...2 Save meter information for future reference Model Number Serial Number Purchase Date ...
Страница 3: ...ONNECTING METERS 10 SETTING THE METER 10 LOGGING DATA 11 DISPLAY AND ALARM CM 0016 CM 0017 ONLY 11 CALIBRATION 11 METER SPECIFICATIONS 13 TROUBLESHOOTING GUIDE 14 SUPPORT 15 WARRANTY 15 LIABILITY 15 RETURNS 15 Welcome Thank you for purchasing our meter Please take some time to read through this manual in order to become familiar with the meter Also please pay special attention to the important saf...
Страница 4: ...le Please do not attempt to open the meter and replace the battery 6 Do not use rechargeable AA batteries 7 For models using AA batteries do not store the meter with the AA Alkaline batteries installed to prevent the potential for battery leakage 8 Use only the supplied 5 6VDC international wall power supply adapter Precisely 5 6V must be applied to the meter Other voltages can cause permanent dam...
Страница 5: ... Accessories A Hydrophobic Vent Filter Kit may be purchased separately These filters are ideal for high humidity environments to allow air flow while keeping humidity out Long lasting use anywhere humidity is very high 95 Order part number ESCM 172 Software Capabilities Our GasLab software will allow users to Manage and download logs Configure Sensor Adjust logging intervals Calibrate the meter Au...
Страница 6: ...l No LCD Battery Type Capacity mAh Qty ESCM 16 Yes Dry AA Cell 1 800 2 600 4 ESCM 17 Yes Dry AA Cell 1 800 2 600 4 ESCM 18 CC No Dry AA Cell 1 800 2 600 4 ESCM 18 No Rechargeable Li Ion 2 200 1 ESCM 19 No Rechargeable Li Ion 2 200 1 ESCM 209 No Rechargeable Li Ion 6 000 1 ESCM 210 No Rechargeable Li Ion 6 000 1 Batteries not included Duracell brand recommended IMPORTANT METERS USING DRY AA CELLS U...
Страница 7: ...IMATED BATTERY LIFE 2 200 33 9 64 9 HOURS To determine the Time to Fill Memory TTFM we use a different calculation TTFM SAMPLING INTERVAL 5 400 DATA LOGS 3 600 For example taking a sample every 30 seconds would mean TTFM 32 5 400 3 600 TTFM 48 HOURS Of course TTFM must be less than EBL This means that in most cases you can completely fill the memory with data logs more than once between charges Ba...
Страница 8: ...an be charged using the supplied universal power adapter or a USB port on a powered computer Li Ion batteries will be fully charge in 5 8 hours and will lose about 8 of their charging capacity per every year of use at 25 C Product Overview This data logger is designed to measure carbon dioxide CO2 percent of relative humidity RH and temperature through diffusion sampling It stores collected data t...
Страница 9: ...dels ESCM 16 and ESCM 17 with display and audible alarm ON OFF switch Data logging starts at switch ON Power ON indicator LED ON OFF switch Data logging starts at switch ON Alarm mute push button Mini USB port Power adapter connector LCD display Mini USB port Used for data transferred and power adapter ...
Страница 10: ...to visually confirm it has reset successfully after connecting it to a USB port on a computer Connecting Meters The first time the meter is connected to your computer the operating system will install the necessary USB drivers as shown in Figure 2 This process could take a few minutes Figure 2 USB Driver Installation Setting the Meter 1 Ensure the data logging switch is in the ON position 2 Connec...
Страница 11: ...ludes a built in audible 80dB alarm and an LCD Liquid Crystal Display back lit display that provides visual indication of the current CO2 level by changing color to green yellow or red depending on CO2 level ranges selected The display will change colors depending on the actual CO2 level readings by setting the Green Yellow and Red ranges The alarm is set per LEED levels by default but can be prog...
Страница 12: ...m accuracy it is recommended to install the device in an environment that will routinely see this low value In addition this meter can be exposed to fresh air for a few minutes between uses to verify calibration by making sure the readings are close to 400 ppm or can be manually calibrated using the GasLab software NOTE Refer to the GasLab User s Manual for complete instructions ...
Страница 13: ...rements Temperature Sensor Range 40 to 120 C Repeatability 0 1 C Accuracy 0 5 C Relative Humidity Sensor Range 0 100 Repeatability 0 1 Accuracy 3 Dimensions L x W x D mm inches 146 1 5 75 x 91 4 3 60 x 32 7 1 30 Data Logging Data Points Programmable Interval Data 15 000 ESCM 16 17 5 400 ESCM 18 18 CC 19 209 210 Date time CO2 RH temp Power Input Voltage Power Consumption Charging Time Battery Type ...
Страница 14: ...ed while logs were being downloaded Connect the meter to the computer and download logs again The display is Blue or showing Sensor Missing The meter s EEPROM has been corrupted Battery or power supply issues Please email our technical support for further assistance CO2 Readings are inaccurate ABC is adjusting the zero point Turn off ABC or ensure the unit is exposed to 400ppm air while data loggi...
Страница 15: ...suse neglect accident modifications or repairs by you or by a third party No employee or reseller of Edaphic Scientific s products may alter this warranty verbally or in writing Use of this device in environments above 95 humidity may cause irreparable damage to the components and is not warranted Liability All liability under this agreement shall be limited to the actual cost of the product paid ...
Страница 16: ... dropping tampering electrical damage etc or if it is beyond the warranty date we will inform you of the cost to fix or replace the product Contact Us We are here to help For information or technical support please contact us info edaphic com au PO Box 1843 Port Macquarie NSW 2444 ...