background image

EDAN Agile PLM Electronic Signature Information

--Signatures related to this document and performed in EDAN Agile PLM.

  
  
文件名称(Document Name):iSE系列多道心电图机维修手册-英文
文件编号(Number):01.54.458572
版本(Version):1.0
产品型号(Product Model):iSE-1015;iSE-1016;iSE-1018;iSE-1019;iSE-
1210;iSE-1615;iSE-1616;iSE-1618;iSE-1619;iSE-1810;iSE
项目编码(Project Code):00011C001
  
签批信息(Signature):

 
作者(Originator) : 严 慧敏 (yanhuimin)      2020-04-30 15:47:28

 
审核人(Reviewers) : 兰 小燕 (lanxiaoyan)      2020-04-30 16:16:29

 
审核人(Reviewers) : 杨 洁 (yangjie)      2020-04-30 15:51:16

 
审核人(Reviewers) : 宋 晓菁 (songxiaojing)      2020-05-06 10:54:08

 
审核人(Reviewers) : 聂 宪忠 (niexianzhong)      2020-04-30 15:50:50

 
审核人(Reviewers) : 聂 宪忠 (niexianzhong)      2020-04-30 15:50:50

 
审核人(Reviewers) : 陈 浩杰 (chenhaojie)      2020-04-30 16:41:37

 
审核人(Reviewers) : 马 巍 (mawei)      2020-04-30 16:14:31

 
审核人(Reviewers) : 焦 欣 (jiaoxin)      2020-04-30 17:46:27

 
审核人(Reviewers) : 聂 宪忠 (niexianzhong)      2020-04-30 15:50:50

 
审核人(Reviewers) : 严 彬彬 (yanbinbin)      2020-04-30 16:40:01

 
审核人(Reviewers) : 肖 文聪 (xiaowencong)      2020-04-30 16:14:27

 
审核人(Reviewers) : 黄 永开 (huangyongkai)      2020-04-30 17:16:59

 
审核人(Reviewers) : 汪 金平 (wangjinping)      2020-05-04 10:42:15

 
审核人(Reviewers) : 明 镭 (minglei)      2020-04-30 16:47:32

 
审核人(Reviewers) : 张 在阳 (zhangzaiyang)      2020-05-04 09:46:40

 
批准人(Approvers) : 肖 文聪 (xiaowencong)      2020-05-06 11:49:02
  

Содержание iSe Series

Страница 1: ...gjie 2020 04 30 15 51 16 Reviewers songxiaojing 2020 05 06 10 54 08 Reviewers niexianzhong 2020 04 30 15 50 50 Reviewers niexianzhong 2020 04 30 15 50 50 Reviewers chenhaojie 2020 04 30 16 41 37 Revie...

Страница 2: ...Copyright Edan Instrument Inc...

Страница 3: ......

Страница 4: ...contained in this manual the user shall not disclose such information to any irrelevant third party The user shall understand that nothing in this manual grants him expressly or implicitly any right o...

Страница 5: ...label advises against certain actions or situations that could result in personal injury or death CAUTION A CAUTION label advises against actions or situations that could damage equipment produce inac...

Страница 6: ...ecture 14 3 2 2 Upper Casing 15 3 2 3 Printer 16 3 2 4 Main Board 17 3 2 5 DE12 ECG Board 18 3 2 6 DE18 ECG Board 19 Chapter 4 Optional and Advanced Functions 21 4 1 Configuring a Barcode Reader 21 4...

Страница 7: ...IV 6 4 Disassembling the Printer Head 35 6 5 Disassembling DE18 Sampling Box 36 Chapter 7 Renewable Parts 38...

Страница 8: ...ions for which EDAN is not responsible may void the warranty Groupware is dismounted stretched or re debugged Unauthorized modification or misuse Damage caused by operating beyond the environmental sp...

Страница 9: ...is confirmed by service engineer 2 The customer is responsible for freight insurance charges when the equipment is shipped to EDAN for service including custom charges EDAN is responsible for the fre...

Страница 10: ...the parts with naked hand Please pack the parts safely before return Please put the RMA number on the parcel Please describe the returned parts as sample of and put the total value on the invoice and...

Страница 11: ...operation 2 Only qualified service engineers can install this equipment and only service engineers authorized by the manufacturer can open the shell Otherwise safety hazards may happen 3 EXPLOSION HAZ...

Страница 12: ...otherwise it may cause a high polarization voltage 15 The disposable electrodes can only be used for one time 16 Do not touch the patient bed table or the equipment while using the ECG together with a...

Страница 13: ...multiple portable socket outlet or extension cord in the medical electrical system unless it s specified as part of the system by manufacturer And the multiple portable socket outlets provided with th...

Страница 14: ...ts may exceed the limits given in the IEC EN 60601 1 and may pose a safety hazard Consult your service personnel 31 The electrocardiograph shall not be serviced or maintained while in use with a patie...

Страница 15: ...or water 5 Do not destroy the battery Do not pierce battery with a sharp object such as a needle Do not hit with a hammer step on or throw or drop to cause strong shock Do not disassemble or modify t...

Страница 16: ...g equipment etc is likely to bring electromagnetic interference 4 The device and accessories are to be disposed of according to local regulations after their useful lives Alternatively they can be ret...

Страница 17: ...ff switch 10 General symbol for recovery recyclable 11 Part Number 12 SERIAL NUMBER 13 Date of manufacture 14 MANUFACTURER 15 AUTHORISED REPRESENTATIVE IN THE EUROPEAN COMMUNITY 16 CE marking 17 Dispo...

Страница 18: ...ral warning sign Background Yellow Symbol Outline Black 21 Non ionizing electromagnetic radiation 22 This way up 23 Fragile handle with care 24 Keep dry 25 Stacking limit by number 26 Handle with care...

Страница 19: ...nformation disassembly procedures and instructions for functional testing and performance verification It is intended to be used by technically qualified service personnel only 3 1 Technical Specifica...

Страница 20: ...1 F 5 C 41 F 40 C 104 F Relative Humidity 15 RH 95 RH Non Condensing 15 RH 95 RH Non Condensing Atmospheric Pressure 70kPa 106kPa 70kPa 106kPa 3 1 4 Power Supply Specifications Mains supply Operating...

Страница 21: ...ter board Printer head Upper casing Boost board Main board Touch screen Power light DE12 ECG board Bluetooth WIFI GPS LTE RF AC DC power adapter Power control Scanner AC input Printer driver Switch In...

Страница 22: ...F G H J I Figure 3 2 Upper casing with printer No Description No Description A Printer F LTE primary antenna B WIFI Bluetooth GPS NFC module all in one G LTE diversity antenna C Charge controller H W...

Страница 23: ...16 3 2 3 Printer Printer shell A Printer roller B Printer driver board C Boost board A B C Printer head Printer driver board A 34 PIN interface to the printer head B Boost board interface C USB interf...

Страница 24: ...3 2 4 Main Board A B C D E H I J K N M L F G O P Q Figure 3 3 Main board interfaces No Description No Description A DC socket connecting to power adapter J Internal interface to the camera B Network p...

Страница 25: ...ce to the speaker O SIM and SD cards slot two in one G Internal interface to the touch screen P Scanner interface H Internal interface to DE12 ECG board Q MIC interface I Internal USB interface to the...

Страница 26: ...iew 19 3 2 6 DE18 ECG Board A B Figure 3 5 DE18 ECG board No Description A Connecting to ECG lead wires B Connecting to the DE18 connection cable USB Interface Definitions of pins Pin Signal Pin Signa...

Страница 27: ...D ECG Cable Socket Lead No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Definitions of upper row AHA RL LL V9 V8 V7 V6 V5 V4 V3 V2 V1 V3R V4R V5R LA RA Definitions of upper row IEC N F C9 C8 C7 C6 C5 C4 C3...

Страница 28: ...n Figures 4 1 and the barcode that functions as the Enter key in Figure 4 2 If successful the barcode reader will make a sound and glow green 3 Connect the barcode reader to the iSE electrocardiograph...

Страница 29: ...Sampling Device Insert the USB device to the electrocardiograph Select System Setting System Upgrade Upgrade ECG Board by USB If the upgrade fails select System Setting System Upgrade Upgrade ECG Boar...

Страница 30: ...2 Power On Test Connect the electrocardiograph with the mains supply check if the power light turns orange Switch on the electrocardiograph and carry out the following inspections The LCD screen is l...

Страница 31: ...e electrocardiograph 3 Check if the network symbol at the notification bar indicates the electrocardiograph is connected to the network If any failure is detected refer to section 5 8 Troubleshooting...

Страница 32: ...Box 1 Open the upper casing and lower casing of the DE18 sampling box Take out the main board 2 Connect to the electrocardiograph via the DE18 connection cable 3 Measure the voltage to earth of the fo...

Страница 33: ...V3 5 8 Troubleshooting WARNING Replace parts components or accessories only with parts supplied or approved by the manufacturer The use of any other parts can lead to inferior device performance and w...

Страница 34: ...r board is defective Replace the board If the electrocardiograph still cannot start up rule out the possibility of this board failure 4 Test whether the line arrangement between USB adapter board and...

Страница 35: ...to copy data from the electrocardiograph to the U disk or SD card Setup error LAN cable failure USB interface or LAN port failure USB storage device failure SD card failure Examine whether the transm...

Страница 36: ...the recorder paper Replace the printer module Replace the main board or boost board or printer driver Replace or repair the recorder wiring The printed report is illegible Some characters or waveform...

Страница 37: ...CG cable failure ECG board failure Attach the electrodes to the patient again or clean the electrode location on body surface with alcohol Replace the ECG cable that is defective Replace the ECG board...

Страница 38: ...iSE Series Electrocardiograph Service Manual Inspection and Troubleshooting 31 electrocardiograph electrical devices Turn on the AC filter on the Filter Setting window...

Страница 39: ...fety tests prior to use 4 The upper casing and printer are complicated to disassemble Please follow the instruction of trained personnel for disassembly 5 High value parts such as the touch screen pri...

Страница 40: ...r adapter Take out the battery Detach 6 cover screws from the lower casing by the M3 Philips screwdriver Open the buckle between the upper casing and lower casing by the pry bar Open the casing Check...

Страница 41: ...he wiring of main board according to the Figure 3 3 in section 3 2 4 Detach the six screws that fix the main board Remove the antennas with a soldering iron Detach the screws and bolts that fix the pr...

Страница 42: ...ch the screws that fix the back shell of the paper tray Remove the paper tray switch from outside Lift the printer bracket and printer head out of the printer Remove the two boards Unplug all wirings...

Страница 43: ...s that fix the printer bracket A B Figure 6 5 Printer head wiring No Description A 34 PIN wiring for printer head B FPC wiring for stepper motor NOTE Unplug the wirings A and B prior to the disassembl...

Страница 44: ...ard 11 Light conductive cover 12 Cross recessed pan head screw M2 5 8 13 Belt hole cap Disassembly Steps 1 Remove the four stopples and the four cross recessed pan head screws M2 5 8 on the pedestal a...

Страница 45: ...h handle Advanced 01 48 099232 iSE upper casing with handle Basic 01 48 099233 iSE upper casing with tablet Advanced 01 48 099234 iSE upper casing with tablet Basic 01 48 099235 iSE lower casing 01 62...

Страница 46: ......

Отзывы: