![EDAC EDAC9 Series Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/edac/edac9-series/edac9-series_quick-start-manual_2357135014.webp)
Page 14 of 24
For Support C61-
-9
-
Or s
DOHV
@e
GDF
.com.au
Control Via ET Commands
As default the E
'$&
9XXX-XXX is set to ET Command Mode, ET Commands are specific to E
'$&
terminals and allow for control, configuration and information requests to be sent to and from the
terminal. In ET command mode AT commands cannot be sent to the unit.
ET commands can be sent via SMS or from configuration tool when directly connected or via an IP
or CSD connection. It is recommended that more complex settings such as changing messages or
phone numbers are made using the configuration tool.
Common ET commands are shown on the next two pages, for a full ET command list visit our
website or contact E
'$&(OHFWURQLFV
.
Common ET Commands
Ref Command
Command Format
Action/Request/
Notes
Typical Response/Notes
1
E
'$&
9900
information
ETI
Send E
'$&
9xxx-
x information
ID:”ID string”
RTC: – Real Time Clock (Date and Time)
REFDATE: – Reference date, Day
counter
TOTAL: – Total time since start
RSTIN: – Time to SW reset
RC SW: PU: – Reset counter SW /
Power Up
SW#: – Software number
HW#: – 95*Hardware number (96* if
E
'$&
9600)
SIGNAL: n MIN: MAX: – Signal strength
real / min / max
SUPPL VOLT: – Supply voltage( V )
CHAN: RS: dBm: LAC: CELL: – Cell
information
MTemp: – Module Temperature(degC)
CID: – Configuration ID
2
Software
Reset MCU
System
ET&SR
May be useful if
it is suspected
the unit has
locked up or
communications
between modem
and external
device have
stalled
3
Show I/O
settings
ETRIS
Show
status/value of
each I/O
1:DI,1,2:DI,1,3:DI,1,4:DI,1,5:DI,1,6:DI,1,7:
DI,1,
I/O 1 Digital Input = 1, I/O 2 Digital Input =
1,…
4
Read A/D
input
ETRAIX
Where X is AI
No., eg:
ETRAI3 reads
analogue input 3
If configured for scaled values, will return
scaled value otherwise raw voltage input
5
Read all A/D
inputs
ETRAIA
Reads all