background image

5.2 Channels

Voltage in - voltage on battery side

Voltage out - voltage on car side

Current load - current flowing through the relay. Positive values: battery to car, negative: car to
battery (charging). Current load is not intended for precise current measurements but for general
information   on   device   load   and   charging.   Have   in   mind   the   measurement   accuracy   when
interpreting results.

 

Temperature – device internal temperature

Flags:

FLAG

SET condition

RESET condition

Overvoltage

Battery voltage > 19V

Battery voltage <= 19V

Undervoltage

Battery voltage < battery saver threshold 
voltage

Battery voltage >= battery saver 
threshold voltage

Overheat

Temperature > 80°C

Temperature <= 80°C

Overheat kill

Temperature > 90°C

Device reset

Overcurrent kill

Current > current limit

Device reset

Emergency kill

Emergency switch activated

Device reset

Powersave kill

Power save switch activated

Power save switch deactivated

CAN kill

CAN kill message received

Device reset

UVLO kill

Battery voltage < 6V

Device reset

Load dump occurred

Alternator is still charging when isolator 
disconnects

Device reset

Battery saver kill

Battery saver function turned off power

Device reset

Overvoltage kill

Voltage exceeded device specification for
too long

Device reset

Device state - refer to Operation principles

Kill countdown - time remaining to go from POWER SAVE ENTRY PROC to POWER SAVE 
or from EMERGENCY ENTRY PROC to OFF

Heartbeat - counter indicating that device is running, incremented with every CAN message
sent

Содержание Battery Isolator

Страница 1: ...t need of external components This means there is no risk of damage to expensive electronic equipment during emergency shutdown It is controlled with two external switches and can be shut down with a...

Страница 2: ...000A Current measurement accuracy 10 Inductive load switching capability 600mJ Enclosure Anodized billet aluminum IP67 rated High current terminals M8 nickel plated terminals or Radlok connectors Sign...

Страница 3: ...down the engine and turns off to very low current consumption level 1mA It is also required to reset the device after a fault condition occurs The input has an internal pull up resistor and is not ac...

Страница 4: ...able wire size Crimping the contacts requires a special tool M22520 2 01 with K1586 positioner for motorsport or military size 24 terminals If you re not equipped with such a tool or suitable gauge wi...

Страница 5: ...switch Each switch will start an entry procedure which the duration of can be set by using light client software It is used to give time for other CAN devices to shut down properly and for the engine...

Страница 6: ...and CAN error 4 1 Under Voltage Lock Out The device has built in Under Voltage Lock Out function to protect itself from invalid operation when the supply voltage is too low If the battery voltage drop...

Страница 7: ...Isolator is configured through the Ecumaster Light Client software The device CAN BUS must be accessed with a USBtoCAN interface or other compatible devices For general Light Client usage refer to Li...

Страница 8: ...e voltage below which Timeout starts counting If voltage rise above threshold voltage during timeout the timeout timer resets Timeout time which needs to pass with voltage below Threshold voltage to a...

Страница 9: ...ature 80 C Temperature 80 C Overheat kill Temperature 90 C Device reset Overcurrent kill Current current limit Device reset Emergency kill Emergency switch activated Device reset Powersave kill Power...

Страница 10: ...urrent kill current limit was exceeded check car wiring and devices for shorts or malfunctions increase Current limit emergency kill emergency switch was activated If this wasn t intended check emerge...

Страница 11: ...on was activated Check battery saver setup Check if alternator is charging the battery when the engine is running overvoltage kill supply voltage exceeded the device specification Check the alternator...

Страница 12: ......

Страница 13: ......

Страница 14: ...06 2019 Initial revision 0 3 17 07 2019 Battery saver and UVLO added 0 4 11 10 2019 Switch type and kill output hints added 0 5 28 11 2019 Drawing for lug and Radlok versions 0 6 12 12 2019 Text revi...

Отзывы: