background image

5

3.3  TEMPERATURE CONTROL

Press 

 and 

 respectively to adjust the CH and 

DHW flow temperature (if an indirect storage tank is fitted). 

When the burner is lit, display shows the   symbol 

.

HEATING

: while boiler is operating in heating mode, the 

display shows the flashing symbol 

 

and the heating flow 

temperature °F / °C.

When connected to an Outdoor Temperature Sensor, 

 

indirectly adjusts room temperature (factory setting 68°F / 

20°C).

DHW

While boiler is operating in DHW mode, display 

shows the flashing symbol   and heating flow temperature 

°F / °C.

3.4 BOILER INFORMATION MENU (See Below)

Press 

  and hold for at least 1 second, to display the 

information indicated in the table. Press 

 to exit.

DESCRIPTION

DESCRIPTION

00

Secondary fault internal code

09

Setpoint Central Heating (°F/°C)

01

Heating flow temperature (°F/°C)

10/11

Manufacturing information

02

Outdoor temperature (°F/°C)

12

Flue sensor temperature (°F/°C)

03

Indirect Tank DHW temperature (boiler CH only)

13

Manufacturing information

04

Domestic hot water temperature (boiler with plate 

exchanger)

14

Identification Open Therm communication

05

Water pressure in heating system (PSI/bar)

15

Manufacturing information

06

Heating return temperature (°F/°C)

16

Manufacturing information

07

Thermo fuse status (000/001)

17

Fan speed (“i17”x100)

08

Not used

18

Manufacturing information

3.5 SHUTTING OFF THE BOILER

To  turn off the boiler, disconnect the electric power supply. 

In the “Off” operating mode   the boiler stays off but the 

electrical circuits remain powered and the frost protection 

function remains active.

3.6 FROST PROTECTION MODE

The electronic boiler management system includes a 

“frost protection” function for the heating system which, 

when delivery temperature falls below 41°F (5°C), lights 

the burner until a delivery temperature of 86°F (30°C) is 

reached.

This function is only operative if the boiler is electrically 

powered and there is gas with normal system pressure and 

the flue is not blocked.

3 - CONTROL

PN 240012896 Rev. A [01/31/2020]

Содержание Utica Boilers MACF-150

Страница 1: ...ier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier USER S INFORMAT...

Страница 2: ...control which has been under water WARNING Fire explosion asphyxiation and electrical shock hazard Improper maintenance and service could result in death or serious injury Read this manual and underst...

Страница 3: ...de central heating as required Hot water is available whenever a hot tap is open Combi models only 2 2 OPERATING INSTRUCTIONS Stop Read ALL Safety information above Set thermostat to lowest setting Tu...

Страница 4: ...ater temperature adjustment to increase the temperature and to decrease it Boiler operating information Operating mode DHW DHW Heating Heating Only Off Reset Exit menu functions BUTTON Explanation 3 1...

Страница 5: ...03 Indirect Tank DHW temperature boiler CH only 13 Manufacturing information 04 Domestic hot water temperature boiler with plate exchanger 14 Identification Open Therm communication 05 Water pressure...

Страница 6: ...If this fault persists call authorized SERVICE technician 118 Hydraulic pressure too low Call authorized SERVICE technician 125 No circulation safety trip control performed via temperature sensor Pres...

Страница 7: ...eaning required Check air vent s for leakage Follow OPERATING INSTRUCTIONS to return to normal operation WARNING Burn and scald hazard Verify Safety Relief Valve discharge piping run to safe discharge...

Страница 8: ...fications subject to change without notice 2020 ECR International Inc 2201 Dwyer Avenue Utica NY 13501 Tel 800 253 7900 www ecrinternational com BDR THERMEA GROUP Name Address Phone Email Installer In...

Отзывы: