6
Model
Max. First
Hour Rating
Continuous
Rating
Boiler
Output
Needed
Min. Boiler
Water
Flow
Through
Coil
Pressure Drop
Through Coil
Gal/Hr. @
Gal/Hr @
(BTU/Hr)
Gal/Min
(Ft. Water)
140F
115F
140F
115F
H20I30
182
242
155
215
116,200
10.0
2.7
H2OI40
202
266
166
230
124,500
10.0
2.9
H2OI40L
193
251
157
215
117,900
10.0
2.8
H2OI50
222
290
177
245
132,800
10.0
3.1
H20I60
240
311
186
257
139,400
10.0
3.2
H20I60L
220
284
166
230
124,500
10.0
2.9
H2OI80
257
328
185
256
138,600
12.0
3.7
H2OI115
309
388
206
285
154,200
12.0
4.0
High Output Units
H2OI80HO
386
507
314
435
235,670
15.0
9.0
H2OI115HO
439
568
336
465
251,780
15.0
9.5
H2OI80HO(C)
386
507
314
435
235,670
15.0
9.0
H2OI115HO(C)
439
568
336
465
251,780
15.0
9.5
Table 2 - Ratings