CAUTION
Ground the air conditioner.
Do not connect the ground wire to gas or water pipes,
lightning rod or a telephone ground wire. lnappropriate
grounding may result in electric shocks.
Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric
shocks.
Connect the outdoor unit wires, then connect the indoor unit wires.
You are not allowed to connect the air conditioner with the power
supply until the wiring and piping is done.
While following the instructions in this installation manual,
install drain piping in order to ensure proper drainage and
insulate piping in order to prevent condensation.
Improper drain piping may result in water leakage and property
damage.
Install the indoor and outdoor units, power supply wiring
and connecting wires should be at least 1 meter away from
televisions or radios in order to prevent image interference or
noise.
Depending on the radio waves, a distance of 1 meter may not be
sufficient enough to eliminate the noise.
The appliance is not intended for use by young children or
infirm persons without supervision.
Don’t install the air conditioner in the following circumstance:
There is petrolatum existing.
There is salty air surrounding (near the coast).
There is caustic gas (the sulfide, for example) existing in the air
(near a hot spring).
The Volt vibrates violently (in the factories).
In buses or cabinets.
In kitchen where it is full of oil gas.
There is strong electromagnetic wave existing.
The appliance shall be installed in accordance with national
wiring regulations.
Do not operate your air conditioner in a wet room such as a
bathroom or laundry room.
An all-pole disconnection device which has at least 3mm
clearances in all poles , and have a leakage current that may
exceed 10mA, the residual current device (RCD) having a
rated residual operating current not exceeding 30mA, and
disconnection must be incorporated in the fixed wiring in
accordance with the wiring rules.
There are inflammable materials or gas.
There is acid or alkaline liquid evaporating.
Other special conditions.
Keep running condition your air conditioning performing at least
every six months clean the filters, coils and fans.
Keep in good working control systems, such as the thermostat.
The comfort temperature is between 21° C and 23° C, holding the
temperature within this range will help the team save more energy.
Do not place the thermostat near spotlights, lamps or heat
producing appliances and the operation of the system may be
inadequate and / or poor.
When using the air conditioner keep doors and windows closed in
conditioned environments in order to keep out hot outside air.
If the area where the air conditioner is going to remain idle, shut
down your computer for saving energy.
In unconditioned spaces should reduce the heat load introduced
by excessive lighting or equipment remain on unnecessarily.