7
REMOTE CONTROLLER
SPLIT AIR CONDITIONER
EPLT
FP/EYE Button
Active/Disable freeze protection function. If pushing more than 2 seconds, the
Intelligent eye function will be activated, pushing more than 2 seconds again to
disable.
During the heating operation(only when the setting mode is HEAT),If pushing this
button more than 2 seconds, the freeze protection function is activated. The unit
will operate at high fan speed with the temperature automa- tically set to 8ºC.The
display window of indoor unit will display FP . For the unit without display area,
the Defrost indicator light will be keeping on for 2 seconds, and then be off for 2
seconds by turns. Press ON/OFF,SLEEP, FP, MODE, FAN SPEED,UP, DOWN button while
operating will cancel the freeze protection function.
Under Intelligent eye function, with the built-in infrared sensor, the unit can detects
existence of humans in the room. If the unit keep detecting no human activity for 30
min, it will automatically enters standby(monitor) status in order to save electricity.
And the unit will automatically start and resume operation if sensing human activity
again.
TIMER ON Button
Press this button to initiate the auto-on time sequence. Each press will increase the
autotimed setting in 30 minutes increments. When the setting time displays 10,
each press will increase the auto-timed setting 60 minutes increments. To cancel
the auto-timed program, simply adjust the auto-on time to 0.0.
TIMER OFF Button
Press this button to initiate the auto-off time sequence. Each press will increase the
autotimed setting in 30 minutes increments. When the setting time displays 10,
each press will increase the auto-timed setting 60 minutes increments. To cancel
the auto-timed program, simply adjust the auto-off time to 0.0
Swing Button
Used to stop or start vertical louver movement and set the desired left/right air
flow direction. The vertical louver changes 6 degree in angle for each press. And
the temperature display area of indoor unit displays " " for one second. If keep
pushing more than 2 seconds, the vertical louver swing feature is activated. And the
display area of indoor unit displays "IIII" , flashes four times, then the temperature
setting reverts back. If the vertical louver swing feature is stopped, it displays "LC"
and remains on for 3 seconds.
Swing Button
Used to stop or start horizontal louver movement or set the desired up/down air
flow direction. The louver changes 6 degree in angle for each press. If keep pushing
more than 2 seconds, the louver will swing up and down automatically.