EIHPTC

CEILING FLOOR TYPE

For inverter type, this switch is used for after-sales service 

purpose only, the user should not push it.

For fixed-frequency type, this function is used to operate the 

unit temporarily in case you misplace the remote control or its 

batteries are exhausted. Two modes including FORCED AUTO 

and FORCED COOL can be selected through the TEMPORARY 

BUTTON on the air-in grill control box of the indoor unit. Once 

you push this button, the air conditioner will run in such order: 

FORCED AUTO, FORCED COOL, OFF, and back to FORCED AUTO.   

FORCED AUTO

The OPERATION lamp is lit, and the air conditioner will run 

under FORCED AUTO mode. The remote control operation is 

enabled to operate according to the received signal.  

FORCED COOL

The OPERATION lamp flashes, the air conditioner will turn to 

FORCED AUTO after it is enforced to cool with a FAN speed HIGH 

for 30 minutes. The remote control operation is disabled.

OFF

The OPERATION lamp goes off. The air conditioner is OFF while 

the remote control operation is enabled.

NOTE

NOTE

This manual does not include Remote Control Operations, see 

the<<Remote Control Owner's manual>>

packed with the unit for details.  

If air conditioner is used outside the above conditions, it may cause 

the unit to function abnormally. 

In high humidity areas, you may observe the presence of condensed 

water on the surface of the unit.  Close doors and windows to revert 

the situation.

Optimum performance will be achieved within these operating 

temperature range. 

Three-minute protection feature

A protection feature prevents the air conditioner from being 

activated for  approximately 3 minutes when it restarts immedi-

ately after operation.

Power failure

Power failure during operation will stop the unit completely.

The OPERATION lamp on the indoor unit will start flashing 

when power is restored.

To restart operation, push the ON/OFF button on the remote 

control.

Lighting or wireless equipment operating nearby may cause 

the unit to malfunction.

Disconnect the unit from the power and then connect the unit 

to the power again. Push the ON/OFF button on the remote 

control to restart operation.

Refrigerant Leakage Detection(optional):

With this new technology, when refrigerant leakage is detected 

by the outdoor unit, EC (if applicable) will appear in the display 

area and a indication lamp will flash in the LED.

Louver Angle Memory Function(optional):  

For some models, the machine is special designed with louver 

angle memory function. Power failure during operation or 

pressing the ON/OFF button on the remote controller will stop 

the unit completely. When the power restores or pressing the 

ON/OFF button on the remote controller again, the unit restarts 

automatically with the previous open angle of the horizontal 

louver by the memory function. So we strongly recommend that 

the open angle of the horizontal louver should not be set too small, 

to prevent water condensation from the horizontal louver. Press the 

Manual control button and the open angle of the horizontal louver 

will be restored to the standard angle.

Use the system in the following temperature for safe and 

effective operation. The Max operation temperature for the 

air conditioner.(Cooling/Heating) 

AIR CONDITIONER OPERATIONS AND PERFORMANCE

3.

Cooling operation

Drying operation

Heating operation

(cooling only type without)

Mode

Temperature

Outdoor
temperature

                            (for the models with low 

                            temperature cooling system)

                            (for special tropical models)

                            (for special tropical models)

temperature

Room

18°C ~ 43°C / 64 °F~109°F        

18°C ~ 52°C / 64 °F~126°F          

-7°C ~ 43°C / 20 °F~109°F

          

-7°C ~ 24°C / 20 °F ~ 76°F          

18°C ~ 43°C / 64 °F~109°F         
18°C ~ 52°C / 64 °F~126°F         

0°C ~ 30°C / 32 °F~86°F

  17°C ~ 32°C

( 62 °F ~ 90°F)

  17°C ~ 32°C

( 62 °F ~ 90°F)

1

1

2

3

2

3

0°C ~ 30°C / 32 °F~86°F

  17°C ~ 32°C

( 62 °F ~ 90°F)

  17°C ~ 32°C

( 62 °F ~ 90°F)

Cooling operation

Drying operation

Heating operation

(cooling only type without)

Mode

Temperature

Outdoor
temperature

                            (for the models with low 

                            temperature cooling system)

temperature

Room

0°C ~ 50°C / 32 °F~122°F          

0°C ~ 50°C / 32 °F~122°F      

-15°C ~ 50°C / 5 °F~122°F 

         

-15°C ~ 24°C / 5 °F~76°F          

TABLE. 3-1

TABLE. 3-1 

(FOR INVERTER TYPE AIR CONDITIONER)

Содержание EIHPTC Series

Страница 1: ...CEILING FLOOR TYPE Thank you for purchasing this ecox product Before using this machine please read this manual and retain it for future reference OWNER S MANUAL EIHPTC EIHPTC ...

Страница 2: ...2 EIHPTC CEILING FLOOR TYPE ...

Страница 3: ...purpose only They may be slightly different from the air conditioner you purchased depend on model The actual shape shall prevail Air flow louver at air outlet Air inlet with air filter in it Installation part Display panel Remote control Drain pipe Connecting pipe Air inlet Air outlet FIG 1 1 OR 1 2 3 5 4 7 6 8 8 8 8 8 8 9 9 7 ...

Страница 4: ...ted current or other wires when a fuse blows out Use of wire or copper wire may cause the unit to break down or cause a fire It is not good for your health to expose your body to the air flow for a long time Do not insert fingers rods or other objects into the air inlet or outlet When the fan is rotating at high speed it will cause injury Never use a flammable spray such as hair spray lacquer or p...

Страница 5: ...nfluence to small children animals and plants may occur Do not allow a child to mount on the outdoor unit or avoid placing any object on it Falling or tumbling may result in injury Do not operate the air conditioner when using a room fumigation type insecticide Failure to observe could cause the chemicals to become deposited in the unit which could endanger the health of those who are hypersensiti...

Страница 6: ...r Timer indicator Operation lamp Alarm indicator PRE DEF indicator cooling and heating type or FAN indicator cooling only type MANUAL TIMER ALARM OPERATION DEF FAN Infrared signal receiver Temperature indicator NOTE DEF indicator cooling and heating type or FAN indicator cooling only type TIMER ALARM OPERATION DEF FAN Infrared signal receiver NOTE DEF indicator cooling and heating type or FAN indi...

Страница 7: ...ting nearby may cause the unit to malfunction Disconnect the unit from the power and then connect the unit to the power again Push the ON OFF button on the remote control to restart operation Refrigerant Leakage Detection optional With this new technology when refrigerant leakage is detected by the outdoor unit EC if applicable will appear in the display area and a indication lamp will flash in th...

Страница 8: ...door unit and remote control at least 1m away from televisions radios stereos and other similar equipment Failing to do so may cause static or distorted pictures A dirty air filter will reduce cooling or heating efficiency please clean it once every two weeks 5 2 ADJUST THE VERTICAL LOUVER When heating Adjust the louver downwards vertically Auto swing Press SWING H button the louver will swing lef...

Страница 9: ... during long time usage If the air conditioner is installed in a dusty place clean the the air filter frequently If the accumulated dust is too heavy to be cleaned please replace the filter with a new one replaceable air filter is an optional fitting 3 2 10 5KW 10 000 36 000BTU h Open the air intake with the screwdriver or similar object Refer to Fig 6 1 Take out the air filter Refer to Fig 6 2 Cl...

Страница 10: ...it A continuous low hissing sound is heard when the system is in operation This is the sound of refrigerant gas flowing through both indoor and outdoor units A hissing sound which is heard at the start or immediately after stopping operation or defrost operation This is the noise of refrigerant caused by flow stop or flow change Symptom 4 3 Outdoor unit When the tone of operating noise changes Thi...

Страница 11: ...ne l is abnormal T2 EPPROM malfu nction Indoor fan motor speed out of control Wate r leve l alar m malfunct ion Outdoor malfu nction Indoor twins communication malfunction Other malfunction of twins 2 5H ZF 0 5H Z ALARM DEF FAN TIMER OPERATION Pipe TEMP Sensor chec king channe l is abnormal T2B NO 1 2 3 4 5 6 7 8 9 10 11 Refrigerant leakage detection malfunction EC TABLE 8 1_A APPLICABLE TO INVERT...

Страница 12: ...hannel is abnormal Water level alarm malfunction Refrigerant leakage detection malfunction Room temperature sensor checking channel is abnormal EEPROM malfunction Outdoor malfunction Outdoor TEMP sensor checking channel is abnormal In Outdoor unit COMM Checking channel is abnormal E1 DC motor speed out of control Outdoor unit low pressure error Eb Ed NO Fl TABLE 8 1_B APPLICABLE TO FIXED FREQUENCY...

Страница 13: ...s in the refrigerating circuit Compressor is malfunctioning Voltage is too high or too low System circuit is blocked Wait for the comeback of power Switch on the power Replace the fuse Replace the batteries or check the controller Set the temperature properly Wait Check leakage and rightly recharge refrigerant Vacuum and recharge refrigerant Maintenance or change compressor Install manostat Use he...

Страница 14: ...smitter of the remote controller is properly directed to the infrared signal receiver of the indoor unit when the ON OFF button is pressed Directly transmit the signal transmitter of the remote controller to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether the timer operation ...

Страница 15: ...15 EIHPTC CEILING FLOOR TYPE ...

Страница 16: ......

Отзывы: