7
EIHPTC
CEILING FLOOR TYPE
For inverter type, this switch is used for after-sales service
purpose only, the user should not push it.
For fixed-frequency type, this function is used to operate the
unit temporarily in case you misplace the remote control or its
batteries are exhausted. Two modes including FORCED AUTO
and FORCED COOL can be selected through the TEMPORARY
BUTTON on the air-in grill control box of the indoor unit. Once
you push this button, the air conditioner will run in such order:
FORCED AUTO, FORCED COOL, OFF, and back to FORCED AUTO.
FORCED AUTO
The OPERATION lamp is lit, and the air conditioner will run
under FORCED AUTO mode. The remote control operation is
enabled to operate according to the received signal.
FORCED COOL
The OPERATION lamp flashes, the air conditioner will turn to
FORCED AUTO after it is enforced to cool with a FAN speed HIGH
for 30 minutes. The remote control operation is disabled.
OFF
The OPERATION lamp goes off. The air conditioner is OFF while
the remote control operation is enabled.
NOTE
NOTE
This manual does not include Remote Control Operations, see
the<<Remote Control Owner's manual>>
packed with the unit for details.
If air conditioner is used outside the above conditions, it may cause
the unit to function abnormally.
In high humidity areas, you may observe the presence of condensed
water on the surface of the unit. Close doors and windows to revert
the situation.
Optimum performance will be achieved within these operating
temperature range.
Three-minute protection feature
A protection feature prevents the air conditioner from being
activated for approximately 3 minutes when it restarts immedi-
ately after operation.
Power failure
Power failure during operation will stop the unit completely.
The OPERATION lamp on the indoor unit will start flashing
when power is restored.
To restart operation, push the ON/OFF button on the remote
control.
Lighting or wireless equipment operating nearby may cause
the unit to malfunction.
Disconnect the unit from the power and then connect the unit
to the power again. Push the ON/OFF button on the remote
control to restart operation.
Refrigerant Leakage Detection(optional):
With this new technology, when refrigerant leakage is detected
by the outdoor unit, EC (if applicable) will appear in the display
area and a indication lamp will flash in the LED.
Louver Angle Memory Function(optional):
For some models, the machine is special designed with louver
angle memory function. Power failure during operation or
pressing the ON/OFF button on the remote controller will stop
the unit completely. When the power restores or pressing the
ON/OFF button on the remote controller again, the unit restarts
automatically with the previous open angle of the horizontal
louver by the memory function. So we strongly recommend that
the open angle of the horizontal louver should not be set too small,
to prevent water condensation from the horizontal louver. Press the
Manual control button and the open angle of the horizontal louver
will be restored to the standard angle.
Use the system in the following temperature for safe and
effective operation. The Max operation temperature for the
air conditioner.(Cooling/Heating)
AIR CONDITIONER OPERATIONS AND PERFORMANCE
3.
Cooling operation
Drying operation
Heating operation
(cooling only type without)
Mode
Temperature
Outdoor
temperature
(for the models with low
temperature cooling system)
(for special tropical models)
(for special tropical models)
temperature
Room
18°C ~ 43°C / 64 °F~109°F
18°C ~ 52°C / 64 °F~126°F
-7°C ~ 43°C / 20 °F~109°F
-7°C ~ 24°C / 20 °F ~ 76°F
18°C ~ 43°C / 64 °F~109°F
18°C ~ 52°C / 64 °F~126°F
0°C ~ 30°C / 32 °F~86°F
17°C ~ 32°C
( 62 °F ~ 90°F)
17°C ~ 32°C
( 62 °F ~ 90°F)
1
1
2
3
2
3
0°C ~ 30°C / 32 °F~86°F
17°C ~ 32°C
( 62 °F ~ 90°F)
17°C ~ 32°C
( 62 °F ~ 90°F)
Cooling operation
Drying operation
Heating operation
(cooling only type without)
Mode
Temperature
Outdoor
temperature
(for the models with low
temperature cooling system)
temperature
Room
0°C ~ 50°C / 32 °F~122°F
0°C ~ 50°C / 32 °F~122°F
-15°C ~ 50°C / 5 °F~122°F
-15°C ~ 24°C / 5 °F~76°F
TABLE. 3-1
TABLE. 3-1
(FOR INVERTER TYPE AIR CONDITIONER)