EADM

SPLIT-TYPE ROOM AIR CONDITIONER

1

4

5

6

7

8

9

10

2

3

A

B

C

The following events may occur during normal operation.

Protection of the air conditioner.

Compressor protection

The compressor can´t restart for 3-4 minutes after it stops.

Anti-cold air (Cooling and heating models only)

The unit is designed not to blow cold air on HEAT mode, when 

the indoor heat exchanger is in one of the following three 

situations and the set temperature has not been reached.

When heating has just started.
Defrosting.
Low temperature heating.

The indoor or outdoor fan stop running when defrosting 

(Cooling and heating models only).

Defrosting (Cooling and heating models only)

Frost may be generated on the outdoor unit during heat cycle 

when outdoor temperature is low and humidity is high resulting 

in lower heating efficiency of the air conditioner.

During this condition air conditioner will stop heating operation 

and start defrosting automatically.

The time to defrost may vary from 4 to 10 minutes according to 

the outdoor temperature and the amount of frost built up on 

the outdoor unit.

A white mist coming out from the indoor unit

A white mist may generate due to a large temperature 

difference between air inlet and air outlet on COOL mode in an 

indoor environment that has a high relative humidity.

A white mist may generate due to moisture generated from 

defrosting process when the air conditioner restarts in HEAT 

mode operation after defrosting.

Low noise of the air conditioner

You may hear a low hissing sound when the compressor is 

running or has just stopped running. It is the sound of the 

refrigerant flowing or coming to a stop.

You can also hear a low “squeak” sound when the compressor 

is running or has just stopped running. This is caused by heat 

expansion and cold contraction of the plastic parts in the unit 

when the temperature is changing.

A noise may be heard due to louver restoring to its original 

position when power is turned on.

Dust is blown out from the indoor unit.

This is a normal condition when the air conditioner has not 

been used for a long time or during first use of the unit.

A peculiar smell comes out from the indoor unit

This is caused by the indoor unit giving off smells permeated 

from building materials, from furniture or smoke.

The air conditioner turns to FAN only from COOL or HEAT 

(For cooling and heating models only) mode.

When indoor temperature reaches the temperature setting on 

air conditioner, the compressor will stop automatically, and the 

air conditioner turns to FAN only mode. The compressor will 

start again when the indoor temperature rises on COOL mode 

or fails on HEAT mode (For cooling and heating models only) to 

the set point.

The air conditioner runs Anti-mildew function after turning 

off the unit.

When turning off the unit under COOL (AUTO COOL, FORCED 

COOL) and DRY mode, the air conditioner will run Anti-mildew 

function for about 10 minutes, then stop the operation and turn 

off unit automatically.

Dripping water generate on the surface of the indoor unit 

when cooling in a high relatively humidity (relative higher 

than 80%). Adjust the horizontal louver to the maximum air 

outlet position and select HIGH fan speed.

Heating mode (For cooling and heating models only).

The air conditioner draws in heat from the outdoor unit 

and releases it via the indoor unit during heating operation. 

When the outdoor temperature falls, heat drawn in by the 

air conditioner decrease accordingly. At the same time, heat 

loading of the air conditioner increases due to large different 

between indoor and outdoor temperature. If a comfortable 

temperature can´t be achieved by the air conditioner, we 

suggest you use a supplementary heating device.

Auto restart-function.

Power failure during operation will stop the unit completely

For the unit without Auto-restart feature, when the power 

restores, the OPERATION indicator on the indoor unit starts 

flashing. To restarts the operation, push the ON/OFF button on 

the remote controller. For the unit with Auto-restart feature, 

when the power restores, the unit restarts automatically with 

all the previous settings preserved by the memory function.

TROUBLESHOOTING TIPS

NORMAL FUNCTION OF THE AIR CONDITIONER

Содержание EADM

Страница 1: ...EADM EADM OWNER S MANUAL SPLIT TYPE ROOM AIR CONDITIONER Thank you for purchasing this ecox product Before using this machine please read this manual and retain it for future reference ...

Страница 2: ...reatment is necessary It is prohibited to dispose of this appliance in domestic household waste For disposal there are several possibilities The municipality has established collection systems where electronic waste can be disposed of at least free of charge to the user When buying a new product the retailer will take back the old product at least free of charge The manufacturer will take back the...

Страница 3: ...ntact your service partner if it requires Never pull the plug out by pulling on the cable Hold the plug firmly and push it out of the plug socket otherwise there is a risk of damaging the cable Do not operate your air conditioner in a wet room such as a bathroom or laundry room Remove all dirt from the power plug and plug it firmly Soiled plugs can cause fire or an electric shock In the event of a...

Страница 4: ... too long with the doors or windows open or if the humidity is very high If the air conditioner as to be used in conjunction with other heaters the air should be refreshed periodically otherwise there is a risk of lack of oxygen Always pull out the power plug if the unit is not going to be used for any lengthy period of time Collections of dust can cause fire Always switch off the air conditioner ...

Страница 5: ...rear Air inlet side Air outlet Horizontal air flow grille Vertical air Row louvers inside Display panel All the pictures in this manual are for explanation purpose only The actual shape of the indoor unit you purchased may be slight different on front panel and display window The actual shape shall prevail INDOOR UNIT OUTDOOR UNIT Air inlet rear Air inlet side Air outlet 4 3 5 2 6 1 9 10 8 7 10 ...

Страница 6: ...nit will operate under FAN ONLY mode atLOWfanspeedforhalfanhour andthenturnoffautomatically For cooling heating models the unit will operate as in the below sequence FAN ONLY mode at Low fan speed Heating operation with LOW fan speed FAN ONLY operation Stop Operation Turn off This function is only available under COOL AUTO COOL FORCED COOL and DRY mode Before selecting the function it is recommend...

Страница 7: ... prop up the panel Once you push the manual button the operation mode is shifted in an order as AUTO COOL OFF The temperature will be set at 24º C 76º F and the fan on Auto After operation close tile panel firmly to its original position CAUTIONS This switch is used for testing purpose only Please do not use it unless necessary To restore the remote controller operation use the remote controller d...

Страница 8: ...SLEEP button on remote controller during cooling heating cooling heating modes only or AUTO operation the air conditioner will automatically increase cooling or decrease heating 1º C 2º F per hour for the first 2 hours then hold steady for the nest 5 hours after that it will switch off This mode saves you energy and brings you comfort at night DRYING operation The temperature is regulated while de...

Страница 9: ...HE UNIT Wipe the unit with soft dry cloth only If the unit is very dirty wipe it with a cloth soaked in warm water Cleaning the air filter and air freshening filter A clogged air filter reduces the cooling efficiency of this unit Please clean the filter once every 2 weeks Lift the indoor unit panel up to an angle until it stops with a clicking sound Take hold of the handle of the air filter and li...

Страница 10: ...this yourself Contact your dealer or service provider Check that the wiring is not broken off or disconnected Clean the indoor unit and filters Check that the air filter is installed Check if the air outlet or inlet is blocked after the air conditioner has not been used for a long time 5 6 1 2 3 4 1 2 3 4 CAUTIONS CAUTIONS Do not touch the metal parts of the unit when removing the filter Injuries ...

Страница 11: ...ormal condition when the air conditioner has not been used for a long time or during first use of the unit A peculiar smell comes out from the indoor unit This is caused by the indoor unit giving off smells permeated from building materials from furniture or smoke The air conditioner turns to FAN only from COOL or HEAT For cooling and heating models only mode When indoor temperature reaches the te...

Страница 12: ...ve set with timer is incorrect Inappropriate temperature setting Air filter is blocked Doors or windows are open Air filter or outlet of indoor or outdoor unit has been blocked Compressor 3 or 4 minutes protection has been activated Wait for power to be restored Check that plug is securely in wall receptacle Replace the fuse Replace the battery Wait or cancel timer setting Set temperature correctl...

Отзывы: