background image

18

Click “Delete database records” button to delete the history
data on the PC. The user should disconnect the device from the
PC to stop the data transfer before they click “Delete database
records” button.

Click “Delete device record” button to delete the data record on
the device.

Language option

Click Language button, enters the Language menu

Содержание DS-102

Страница 1: ...USB Temperature and Humidity Data Logger Instruction Manual Model DS 102 ...

Страница 2: ... Mode 8 4 4 Sleep Mode 8 4 5 Calibration Mode 9 4 5 1 Temperature calibration 9 4 5 2 Humidity calibration 9 4 6 Logging Mode 9 4 6 1 Cycle Mode 10 4 6 2 Acyclic Mode 10 4 6 3 Segmented Mode 10 4 7 Other Features 11 4 7 1 History Clear 11 4 7 2 Memory Status 11 4 7 3 Low Battery Condition 12 5 Software 12 5 1 System requirements 12 5 2 Installation of the Software 12 6 Specification 19 7 Warranty ...

Страница 3: ...3 1 Display 2 Set key 3 key 4 key 5 USB port ...

Страница 4: ...ment Small simple and affordable our DS102 Data Logger can measure and record temperature and humidity data at specified intervals ranging from once every 8 seconds to once every 4 hours It is our goal to bring you accurate low cost easy to use data logger that integrate easily into the user s working environment 1 1 Package Contents 1x data logger unit 1x USB cable 1x CD ROM 1x 3V lithium battery...

Страница 5: ...erature unit in F or C Time date and unit synchronized your PC Low battery indicator 2 Installation 2 1 Insert battery 1 First use a large coin to open the battery cover at the back of the unit 2 Check the correct polarization insert 1 x 3V CR2032 lithium cell positive pole up into the battery compartment and replace the cover 3 When the battery is inserted all the segments of the LCD display for ...

Страница 6: ...T and buttons at the same time for 5 seconds to enter Calibration mode BUTTON In normal display press button to alternate the display of Max Min and current temperature humidity In setting mode press button to increase the value of information being set In Max Min mode press button for 2 seconds the Max or Min value will be reset to current reading BUTTON In normal display press button for 2 secon...

Страница 7: ...flashing You can press the SET button again to skip any step as defined below 1 12 24 hour format 2 Manual time setting hour minutes 3 Date setting DD MM MM DD 4 Calendar setting year month date 5 Temperature display unit degree Celsius or Fahrenheit 6 Logging interval setting from 8 seconds to 4 hours default 5minute The temperature and humidity data will be measured per 60 seconds as default and...

Страница 8: ...and minimum records will display Press button again to return to the Normal mode While in Max or Min mode press button for 2 seconds the Max or Min value will be reset to current reading Note Press SET button or wait 30 seconds and the MAX MIN Mode will return to normal mode 4 4 Sleep Mode If LCD AUTO OFF function was chosen on the PC software the device will automatically enter sleep mode if no b...

Страница 9: ...nd a mercury or red spirit fluid thermometer Bi metal dial and other digital thermometers are not a good source and have their own margin of error Using a local weather station in your area is also a poor source due to changes in location timing airport weather stations are only updated once per hour and possible calibration errors many official weather stations are not properly installed and cali...

Страница 10: ...ging stops Logging will continue when memory is cleared via the PC software 4 6 3 Segmented Mode You can set max 4 time periods through the setting menu on the PC software These periods can t be overlapped The time period must be later than the current time It will start logging from the set start time and stop from the set end time in a time period Time period icon Time period 1 Time period 2 Tim...

Страница 11: ...ng mode Press and hold the button it will indicate CLEAR on the screen and the memory icon will flash which means ready for clearing history record 4 7 Other Features 4 7 1 History Clear While in Normal Mode press and hold the button for 2 seconds it will indicate CLEAR on the screen and the history data will be cleared 4 7 2 Memory Status There are 10 bar graphs to indicate the memory store capac...

Страница 12: ...windows 8 windows 10 Internet Explorer 6 0 or above Processor Pentium III 500 MHz or above Memory at least 128MB 256MB recommended CD ROM Drive Data logger and PC must be connected by USB cable 5 2 Installation of the Software 1 Switch on your PC and insert the CD ROM into the CD ROM Drive 2 Double click DataLogger exe 3 Choose the language and then install the DataLogger exe on your PC 5 3 Basic ...

Страница 13: ... data will be uploaded to PC automatically and the icon of will be displayed Otherwise the will be displayed It will generate a unique Device ID for each data logger Tool Bar The tool bar at the top of the screen has 4 options Menu Management Language and Help Menu option Click setup button enters the Setup Menu ...

Страница 14: ...Seconds to 240 minutes Time display Set Time display as 12 hours or 24 hours mode Mode Set the logging mode among Cycle Mode Acyclic Mode and Segmented Mode Temperature unit Set the device to read in either Celsius C ...

Страница 15: ... Offset Value Temperature and humidity offset value can be set Click Save to save the settings Click History button to enter History Menu This screen allows the viewing of the recorded data and also provides a path to export the data to an Excel compatible CSV file If you wanted to see all history data in a desired time period choose the time duration and press Search to reload the history data If...

Страница 16: ... button to enter Graph Menu This screen allows the viewing of the history data plotted in graph format and also provides a path to export the data to a jpeg file If you want to see more details just use your mouse to select the area you wanted and the display will be automatically updated in more detailed scale ...

Страница 17: ...17 Management option Click management button enters the Management menu ...

Страница 18: ...n the PC The user should disconnect the device from the PC to stop the data transfer before they click Delete database records button Click Delete device record button to delete the data record on the device Language option Click Language button enters the Language menu ...

Страница 19: ... the PC and download the changes into the base station the setting change will be refreshed when next full minute arrives on the base station 6 Specification Memory Max 20 736 temperature and relative humidity readings Logging Interval 8 seconds to 4 hours Measure Temperature Range 40 to 140 F Temperature accuracy 1 0 F under 32 122 F Measures humidity range 10 99 RH Humidity accuracy 4 under 20 8...

Страница 20: ...anship This limited warranty begins on the original date of purchase is valid only on products purchased and only to the original purchaser of this product To receive warranty service the purchaser must contact us for problem determination and service procedures This warranty covers only actual defects within the product itself and does not cover the cost of installation or removal from a fixed in...

Отзывы: