8
BEFORE INSTALLATION
INSTALLATION SPACE
Ensure there is enough space around the unit,
confirm the bathroom door or shower door will not
hit the unit when they open.
Ensure the minimum distance from the wall to the
center of the floor drain is 305mm or 12” long.
A GFI plug is required close to the unit.
WATER PRESSURE
Minimum required water pressure:
0.1MPa (1.0kgf/cm
2
) (flow of water is greater or
equal to 20L or 5.3 gallon per minute)
Unit may not function well if water pressure fails to
reach this level
Check the water pressure: open the valve and let
the water run into a bucket for 15 seconds, if water
in the bucket is more than 4L, minimum water
pressure is met.
INSTALLATION DRAWING PLAN
CAUTION
The drawing plan is not the actual scale of the unit.
When doing the installation in cold weather, leave the unit in room temperature
for at least four hours before installing.
30
5m
m/
12
"
305