THE  FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND 

FOLLOWED DURING BOTH INSTALLATION AND OPERATION.

WARNING: 

Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this product.   

Equipment damage,  injury  to  personnel  or death could result from improper installation.  Raritan En-

gineering Company, Inc. accepts no responsibility or liability for damage to equipment, injury or death 

to personnel that may result from improper installation operation of this product.

WARNING:  HAZARD OF SHOCK OR FIRE  

 

Always use recommended fuse, circuit breaker and wire size.

 

Motors and relays used with this product are “Ignition Protected”.  They are not however, ex- 

 

                          plosion-proof as defined in 46CFR 110.15-65(e), Subchapter J-Electrical Engineering. 

   

 

DO NOT

 run this system dry (without water).

   

 

DO NOT

 run continuously for more than 30 seconds.  

WARNING:  HAZARD OF FLOODING 

- Always shut off seacock(s) before leaving the boat unattended.  

 

Whenever  possible  hose  connections  should  be  secured  using  two (2) all-stainless steel hose   

                          clamps.  Integrity of clamps, hoses and fittings should be checked periodically.

 

INTRODUCTION

The  Crown  Head  is  a  powerful  centrifugal  macerating 

toilet that thoroughly breaks down waste in preparation for 

treatment or holding and requires little maintenance.  It can 

be ordered with a 90 degree or a straight discharge fitting. 

Available in marine-size or household-style bowl. 

OPERATION

CAUTION:

  

The Crown Head motor is designed to 

be used as a toilet and is not rated for continuous 

duty. 

The Crown Head doesn’t require special toilet  paper, 

however,  hard  objects  or  stringy  substances  (paper 

towels,  feminine  hygiene  products,  filter  cigarettes, 

etc.) 

must not

 be thrown into the toilet as they will 

cause damage.

A.  Momentary Operation Using Momentary Flush 

Switch (Part#PRS) - not included:  

Depress button 

and hold. Water should appear in the bowl within 

one to four seconds.  Flush as necessary.

  

 

 

       

   

   MAINTENANCE

1.  Refill the reservoir when empty; occasionally check 

that it has not run dry. 

  C.P., Cleans Potties, (1PCP32) helps minimize the 

need for cleaning.

Use only Raritan Cleans Potties as an additive in the 

Concentrate tank.  Other products may cause damage 

to the internal parts of the toilet.  

2.  Using  C.P.  a  bio-enzymatic  toilet  bowl  cleaner 

(available from Raritan Engineering) will keep the 

bowl clean and fresh smelling.

Do not use any chemical that contains ammonia, ethyl 

acetate, phosphoric acid or concentrated chlorine 

bleach as a cleaner.  These may cause damage to the 

toilet.

3.   Make a periodic visual check for leaks at the base of the 

toilet and at hose connections.

4.   Check  semiannually  to  ensure  all  wire  terminals  and 

junctions are corrosion-free.

5.  When boat is not in use, flushing the system with fresh water 

will help minimize odors and reduce mineral buildup.

crown head

CENTRIFUGAL DISCHARGE SERIES AUTOMATIC MARINE TOILET

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Model and Serial #

Link to online 

Warranty 

Registration

L91  1022jlc

Содержание Crown Head CW912

Страница 1: ...e or household style bowl OPERATION CAUTION The Crown Head motor is designed to be used as a toilet and is not rated for continuous duty The Crown Head doesn t require special toilet paper however har...

Страница 2: ...ly siphonandcheck valve assembly Concentrate tank 2 oz 59ml of C P two mounting strips and an owner s manual Crown Head units purchased for use with 120 240 volt AC power will also include a rectified...

Страница 3: ...Fuse or Circuit Breaker See Specification Chart Pos Voltage from Battery or DC Power Panel Battery Lug Solenoid Relay CDS 14 Awg Wire Ground Neg Crown Head Pos Wiring the Crown Head DC Unit with Momen...

Страница 4: ...empty occasionally check that it has not run dry C P Cleans Potties 1PCP22 helps minimize the need for cleaning ethyl acetate phosphoric acid or concentrated chlorine bleach as a cleaner These may cau...

Страница 5: ...eplace impeller loose from center bushing 2G Clogged strainer 2G Clean debris from strainer 3 Foul odors from toilet area 3A Marine life lodged in rim of bowl 3A Remove and flush bowl with pressure ho...

Страница 6: ...on F149VT Set Screw 2 G15 Impeller Washer 2 G13W Pump Impeller Assembly w 2 G15 G2M Impeller Wear Plate M23A Lockwasher 4 M30 Hex Nut Brass 2 M31 Flat Washer Brass 2 RNI Nylon Bowl Mounting Washer 4 V...

Страница 7: ...Clamp 7 L91 0116jlc Specify Voltage 7 L91 0116jlc M23A C253 CH55A G13W CHM Specify Voltage CH136 CH37E CH29A CH291 crown head EXPLODED PARTS VIEW CENTRIFUGAL DISCHARGE SERIES CH136 CH37 CR1 CH58 1118...

Страница 8: ...to or misuse of this product This warranty also does not cover damages to equipment caused by fire flood external water excessive corrosion or Act of God 3 ANYEXPRESSWARRANTYNOTPROVIDED HEREIN ANDANYR...

Отзывы: