12
Programming Face Plate Timer
ECOWATER
S Y S T E
M S
Number of People
Iron (parts per million)
1 -- 2
3 -- 4
5 -- 7
8 -- 10
1
4 days
3 days
2 days
1 day
2
4 days
3 days
2 days
1 day
3
4 days
3 days
1 day
1 day
4
3 days
2 days
1 day
1 day
5
3 days
2 days
1 day
1 day
6
2 days
1 day
1 day
1 day
7
2 days
1 day
1 day
1 day
NOTE:
If the water supply has high turbidity (sand, silt, sediments, etc.) set the filter to recharge more
often than the table above shows.
C. Set Recharge Time
1. Press the UP or DOWN keypads until the correct
recharge time shows, being sure AM or PM shows
in the display. Default for this display is 12:00 AM.
2. Press the SELECT keypad once to set the days
to recharge and advance to the next set up screen.
II.
Press and hold the RECHARGE keypad for three
seconds until RECHARGE NOW begins to flash in
the display, starting a backwash. This backwash
flushes “fines” from the new mineral, and purges air
and bleach remaining from the sanitizing procedure.
The filter returns to service in about 30 minutes.
III. RESTART THE WATER HEATER:
Turn on the
electric or fuel supply to the water heater, and light
the pilot, if applies.
NOTE:
The water heater is filled with unfiltered water
and as hot water is used, it refills with filtered water.
In a few days, hot water will be fully filtered. To have
fully filtered water immediately, wait until the re-
charge (step II above) is over. Then, drain the water
heater until water runs cold.
IV. THE TIMER IS NOW PROGRAMMED AND
INSTALLATION IS COMPLETE.