background image

Contents

Contents

Product Overview

Safety Cautions

Mechanism of HOCl Generation

Specification

Limited Warranty

25

24

22

18

16

14

12

5

4

3

How to Use

Troubleshooting

Installation

Component Identification

SLB - 120  HOCl Generation System

3

01

.

02

.

03

.

04

.

05

.

06

.

07

.

08

.

09

.

10

.

Содержание SLB-120

Страница 1: ...w Safety Cautions Mechanism of HOCl Generation Specification Limited Warranty 25 24 22 18 16 14 12 5 4 3 How to Use Troubleshooting Installation Component Identification SLB 120 HOCl Generation System...

Страница 2: ...set Flow Regulator Power Cable 1 ea Connecting Tube 5 m Chlorine Test Paper 1 ea Make sure to check there is no damage caused by external shock to the box before opening the package SLB 120 Product Ov...

Страница 3: ...change This manual provides safety information for intended use of this device and for protecting the users from unexpected injuries or damages Please read carefully the guidelines and warnings herein...

Страница 4: ...the HOCl outlet 6 When installing on a table install it horizontally on a stable table 7 For the optional specifications contact your local seller 8 If re location is needed after installation contac...

Страница 5: ...cket outlets This may cause a fire or electric shock Do not pull the power cord This may cause a fire or electric shock Do not touch the power plug with wet hands Do not twist or press the power cord...

Страница 6: ...seller 1 When detecting strong chlorine odor stop operation immediately ventilate the area and contact your local seller 2 Ensure there is adequate ventilation while using the device 3 Do not operate...

Страница 7: ...exposed to light 4 When using stored HOCl check the pH and chlorine concentration before use 1 Do not add anything to HOCl If any chemicals added this may generate chlorine gas 2 Do not use HOCl at 50...

Страница 8: ...water before disposal 6 Make sure to ventilate when using Chlorine gas may be generated 7 When spilled on the floor or appliances wash it with plenty of water 8 Keep away from direct sunlight 9 Handl...

Страница 9: ...ted clothing or shoes and wash skin with plenty of water Do not try to neutralize the acid with alkaline solution Eye contact Do not rub your eyes and wash immediately with running water for at least...

Страница 10: ...Hypochlorous acid HOCl through electrolysis of 3 HCl and dilution with water Electrolysis In general electrolysis refers to the oxidation reduction reaction of an electrolyte using electric current H...

Страница 11: ...SLB 120 Mechanism of HOCl Generation Chlorine Concentration 20 40 ppm HOCl Solution pH 5 0 6 5 13 HOCl Generation Process...

Страница 12: ...dy Power button Display Mechanical compartment Control panel Raw material container Power connection Control panel vent Mechanical compartment vent Level sensor connection HOCl outlet Water supply con...

Страница 13: ...Press 1 2 seconds to start and stop HOCl generation System status Systeminformation Front control panel User interface 15 Menu Description Date Displays the date information Flow rate Displays the cur...

Страница 14: ...Installation SLB 120 Installation and Operation SLB 120 Installation 16 HOCl Generation System...

Страница 15: ...olution tank to the 3 HCl solution level sensor Close the 3 HCl solution tank cover Close the tank cover carefully 3 HCl solution tank Cap 3 HCl solution tank cover 3 HCl solution level sensor Install...

Страница 16: ...on history Diagnosis Self check for normal operation Service Only for a qualified technician Press 1 2 seconds to enter system menu Press to return to the previous menu Press to move to the next menu...

Страница 17: ...120 How to use Rear Front After Installation Connect the power plug into Power Socket and turn on Power Switch to operate The Power Button lights on in red When press Power Button for 1 2 seconds it...

Страница 18: ...ration System automatically checks internal components Process Checking message is shown on the display and then Complete message is displayed If there is no error Standby message is displayed If eith...

Страница 19: ...leted press the HOCl button for 1 2 seconds to change red LED to blue LED then HOCl generation starts The generated HOCl will be stored in a storage tank To stop the HOCl generation press HOCl button...

Страница 20: ...he 3 HCl solution tank to the 3 HCl solution level sensor Cause 1 The flow rate is low Action 1 Make sure the water pipe is fully opened Cause 2 The flow rate is high Action 2 3 Please contact your lo...

Страница 21: ...SS Missing Processing HOCl Status Leak Cause 1 The 3 HCl solution pump motor does not work 23 Action 1 Please contact your local seller Cause 1 Gas Leak Action 1 2 Cause 2 GSS Missing Gas Sensor Signa...

Страница 22: ...ition production volume and chlorine concentration may vary 2 Specifications may be changed without prior notification to improve the performance of the product 3 The life cycle of the electrolyzer ma...

Страница 23: ...r not guaranteed by your local seller is not covered under warranty Limited Warranty cover Within that one 1 year period from the original purchase SeouLin Bioscience will at its option repair replace...

Страница 24: ...HOCl Generation System 26...

Отзывы: