49
2.3.3.4 LCD backlight control.
Each press of any button of the radiometer activates the LCD backlight for circa
6 seconds. Press THRESHOLD button twice (time between presses should not exceed
0.5 s) to turn on a continuous LCD backlight. Press THRESHOLD button twice once
again to disable continuous LCD backlight.
2.3.3.5 Batteries status control.
Irrespective of the chosen operating mode, the radiometer carries out a non-stop
control of batteries status. The results of control are displayed on the LCD with a
battery status symbol
(6) (Figure 2.1), which consists of four segments.
The number of blinking segments shows the level of batteries discharge. No
segment of the status symbol blinks with a fully charged batteries. When batteries
gradually discharge, one segment starts blinking first, then two, etc. All segments
blink with fully discharged batteries.
Blinking of three or four segments is accompanied by short audio signals. This
means that the batteries should be replaced.
Содержание STORA-ABG RKS-01
Страница 1: ...RKS 01 STORA ABG RADIOMETER DOSIMETER Operating Manual ...
Страница 2: ......
Страница 24: ...22 ...
Страница 27: ...25 Figure 1 2 Appearance of the radiometer top view ...
Страница 29: ...27 Figure 1 3 Appearance of the radiometer bottom view ...
Страница 64: ...62 Figure 2 5 LCD of the radiometer submode of the alarm threshold level programming ...
Страница 70: ...68 Figure 2 8 LCD of the radiometer submode of measurement result saving ...
Страница 86: ...84 Figure 2 12 LCD of the radiometer submode of time and date correction time programming ...
Страница 88: ...86 Figure 2 13 LCD of the radiometer submode of time and date correction year programming ...
Страница 90: ...88 Figure 2 14 LCD of the radiometer submode of time and date correction date programming ...
Страница 93: ...91 Figure 2 15 LCD of the radiometer alarm clock mode ...
Страница 94: ...92 Figure 2 16 LCD of the radiometer submode of the alarm clock triggering time programming ...
Страница 96: ...94 Figure 2 17 LCD of the radiometer submode of the alarm clock triggering time programming ...
Страница 99: ...97 Figure 2 18 LCD of the radiometer mode of data communications control with the PC ...
Страница 101: ...99 Figure 2 19 LCD of the radiometer mode of data communications control with the PC ...
Страница 104: ...102 Figure 2 20 LCD of the radiometer mode of measurement results viewing saved in the nonvolatile memory ...
Страница 106: ...104 Figure 2 21 LCD of the radiometer measurement results viewing ...
Страница 109: ...107 Figure 2 22 LCD of the radiometer submode of measurement results clearing stored in the nonvolatile memory ...
Страница 133: ...131 APPENDIX А Anisotropy horizontal plane Figure А 1 ...
Страница 134: ...132 APPENDIX А Anisotropy vertical plane Figure А 2 ...