"Intensity query for 100msec" frame format - data display system to detecting unit:
D7 D6 D5 D4 D3 D2 D1 D0
0 1 0 1 0 1 0 1 Byte 55h - start-of-frame character
Byte AAh
1 0 1 0 1 0 1 0
0 1 1 1 0 0 0 0
D7…D4–
protocol v1.3 character
address
D7…D0–
detecting unit’s address*
0 0 0 0 0 1 0 0
D7…D0–
“Intensity for 100msec” frame code
control
arithmetical checksum with a carry
*
- 0FFh address – broadcast address. All detecting units respond to the query with such address.
“Intensity for 100msec”
frame format - detecting unit to data display system:
D7 D6 D5 D4 D3 D2 D1 D0
0 1 0 1 0 1 0 1 Byte 55h - start-of-frame character
Byte AAh
1 0 1 0 1 0 1 0
0 1 1 1 0 0 0 0
D7…D4–
v1.3 protocol character
address
D7...D0
–
detecting unit’s address
0 0 0 0 0 1 0 0
D7…D0–
“Intensity for 100msec” frame code
Rate0 (low byte)
Rate for 100msec(unsigned integer)
Rate 1
control
arithmetical checksum with a carry
This package can be used to organize search mode because the intensity here is provided without real-