20
9. OPERATING INSTRUCTIONS
-
The user of the electric heater
shall provide water supply and power supply for the system.
-
The user shall make sure that sealing is proper and control the system operating pressure.
-
Make adjustments for heater or room temperature depending on the system function mode and user’s
individual preferences.
-
In case of deviation from the parameter settings, the user shall inform the authorized service dealer.
-
Maintenance shall be performed by authorized personnel experienced in control and operation of this
device.
-
In case of power failure and after power supply is restored, the electric heater will restart automatically.
10. COMMISSIONING
- This heater shall be started only upon completion of inspection and acceptance of all connections to the
heating system, all electrical connections and the external line.
- Ensure that the heating system valves are open; check system pressure, as well. Enable the automatic fuse
of the electric heater and enter the correct settings. Heating systems can be filled only with water or water
containing antifreeze agent.
11. CONDITIONS PRECEDENT FOR COMMISSIOING AND GUARANTEE SERVICE –
GENERAL REQUIREMENTS:
This electric heater/module is intended for installation using wall mount brackets, only for walls that
can support its weight. Select the location for this electric heater/module to ensure easy access –
distances as per the process requirements on all four sides.
1.
This heater/module shall be installed in a location that can ensure convenient conditions for
maintenance (easy access to the device) and possibility to open the front cover.
2.
This heater/module shall be wall mounted at a minimum height of 1 m from the floor.
3. Install a filter upstream the pump (filter is a heater accessory) as per the manufacturer’s instruction
manual, attached.
1.
Prevent contact of the heater with building materials.
2.
Install screw connectors at the heater inlet and outlet.
3.
Perform a hydraulic test of the system with a factor of 1.25 over the operating pressure.
4.
Be sure to check the heater settings during commissioning. Actual control is performed during hot
testing.
5.
The guarantee becomes effective as from the date of commissioning, however not later than six
months from the purchase date.
12.
PRODUCT WARRANTY DATA:
Product Type___________________________________________________________________________
Serial № ______________ date of manufacturing _____________________________________________
Note: The Manufacturer reserves the right on structural modifications of this device.
Date: 20.01.2021
Содержание Deluxe BH 207
Страница 5: ...5 Electric diagram a single phase option ...
Страница 6: ...6 Electric diagram a three phase option ...