Страница 3: ...erforming any operations on the product The manual features a number of icons that highlight the most important instructions 2 2 Important Carefully read this booklet which describes all the steps req...

Страница 4: ...d 2 Safety information 3 Introduction 3 1 Liability 3 2 Spare parts 3 3 What are pellets 4 Safety device 4 1 No flame in the fireport 4 2 Temporary power failure 5 Assembly installation and start up 5...

Страница 5: ...warranty coupon must be detached and sent within eight days from purchase to ecoteck srl Via Kupfer 3 Palazzolo s O Brescia 25036 27 9 Warranty 9 1 Warranty certificate Ecoteck srl thanks you for the...

Страница 6: ...e handle and pipes heat up considerably during operation these parts must only be touched using suitable protective equipment 3 General information The ILARIA pellet stove must only be used in residen...

Страница 7: ...irepot daily as not all pellets have the same high quality standard The glass is automatically cleaned by a flow of air nonetheless a slight grey film will tend to form on the glass after a few hours...

Страница 8: ...Ash 1 5 Specific weight 1 0 kg dm3 The pellets must be transported and stored completely dry Upon contact with moisture they swell up and can no longer be used Consequently they need to be protected a...

Страница 9: ...eat due to the malfunction of the tangential fan the thermostat is activated stopping the feed screw VACUUM SWITCH THERMOSTAT WHIT MANUAL RESET 8 23 23 Only a clean and unblocked firepot will ensure t...

Страница 10: ...wing cleaning instructions carefully Failure to follow the instructions may cause operating problems of the stove 8 1 Cleaning the surfaces To clean the surfaces of the painted metal parts use a rag d...

Страница 11: ...nveyor 7 5 5 Operating hours menu The ORE LAVORO OPERATING HOURS menu item shows the total operating hours of the stove 7 5 6 Display Settings menu Many of the operating parameters of the stove are lo...

Страница 12: ...user and maintenance manual 2 Remove all the equipment placed inside the hopper when packing the stove 20 7 5 2 Timer thermostat The timer thermostat function allows the stove on off times to be set...

Страница 13: ...nt and the grease in the tube bundle 6 Tips Do not switch the stove on intermittently This may cause sparks that shorten the life of the electrical components Do not touch the stove with wet hands The...

Страница 14: ...pens The stove starts the shutdown procedure after around 10 minutes it will switch off completely MANCA DERESS NO DRAUGHT The alarm is signalled if the draught safety thermostat contact opens The sto...

Страница 15: ...to the minimum value of 1 the value is shown on the display P2 Increase heat When in set heat mode or in operating mode and the room temperature is less than the temperature set point this button is u...

Страница 16: ...e thermostat opens External thermostat open TAmb TSetTerm The stove works at the set heat output until reaching TSetAmb TAmb TSetAmb after which the economy phase starts TAmb TSetAmb Display The LCD s...