background image

Your VorTech Wireless Wave Driver

General Operational Modes

Constant Speed Mode

When a pump is in constant speed mode, the dial is used to set the operational speed. If  
this pump is a master, the associated slave pumps will replicate the master.  

Reef-Crest Random Mode

When a pump is in Reef-Crest Random Mode, the dial is used to set the maximum 
operational speed, and the driver will automatically randomize the pumps output to 
simulate a high energy reef-crest environment. If  this pump is a master pump, the 
associated slave pumps will replicate the master in sync or anti-sync modes.

Lagoonal Random Mode

When a pump is in Lagoonal Random Mode, the dial is used to set the maximum 
operational speed, and the driver will automatically randomize the pumps output to 
simulate a low energy lagoonal reef  environment. If  this pump is a master, the associated 
slave pumps will replicate the master in sync or anti-sync modes.

Pulse Mode

When a pump is first entered into Pulse Mode, you must set the maximum pump speed 
by adjusting the dial. When the desired speed is achieved, press the Set button to lock 
this speed. The LED will now begin to blink. This blinking LED represents the pulsing 
frequency. Now adjust the dial to make the pump pulse faster or slower. 

Feed Mode

To enter Feed Mode, press and hold the mode button for three seconds. The LED will 
now blink white indicating that the pumps are in feed mode. Regardless of  your system’s 
master/slave pump configuration, all pumps will enter feed mode when that mode is 
selected on any one pump. The pumps will spin very slowly for ten minutes and then 
resume their prior operating conditions. 

Battery Backup Mode

When a battery backup accessory is added to the VorTech pump the pump will 
automatically switch to Battery Backup mode during a power outage. The pumps will run 
at the minimum speed to maximize their run time during this critical period.

The wireless wave driver has seven different modes of  
operation, and can be assigned to a master or a slave 
pump configuration.  If  you assign a pump to be a 
master, it will communicate wirelessly with the slave 
pumps. 

There are two buttons and one dial on your driver.   
Use the mode button to switch between the different 
modes of  operation.  The dial and set button will be 
used to adjust the speeds and frequencies of  the 
different modes.

The VorTech utilizes very powerful magnets and can cause severe personal injury.

• 

NEVER connect the two halves of  this device without a proper spacer in-between.

• 

NEVER place either half  of  this device near magnetically attractive surfaces or sensitive 

• 

electronics.
The motor and driver can become HOT.  Be cautious around these surfaces.

• 

Never run the pump dry as the heat buildup may cause damage to your components.

• 

Warnings

Attach the VorTech

Attach the motor assembly

Apply the rubber gasket at the chosen location for the VorTech 

• 

pump, on the outside of  your aquarium. 
Apply the cord mounting tab approximately 2” above this loca-

• 

tion. Make sure the glass is clean and free of any grease or 

dirt prior to applying this tab.
Place the VorTech motor, with or without the pin spacer at-

• 

tached, upon the black gasket, and secure the cord to the 
mounting tab using one of  the provided wire-ties. 
The cord must be positioned pointing upwards so that if  the 

• 

VorTech were to fall off  the aquarium, it does not swing and 
damage your aquarium. When operating, make sure the gasket 
is properly recessed within the pin spacer.

Attach the propeller housing

Apply the wet gasket/cover to the rear of  the propeller housing. 

• 

Place this into the aquarium, making sure to allow ALL air to 

• 

escape from the propeller housing.
Carefully connect both halves of  the pump together and visually 

• 

align both halves of  the pump. 

Align the VorTech

Turn the speed up to the maximum speed by using the 

• 

speed control knob on the driver. 
Plug the power supply into the driver. If  vibration or 

• 

noise is detected, carefully adjust the propeller hous-
ing by moving it VERY slightly left, right, up or down, 
until the noise/vibration is eliminated or minimized as 
much as possible.
After alignment has been ensured, turn the speed 

• 

control knob to achieve the desired flow rate within 
your aquarium. 

IMPORTANT: If  the VorTech is not properly aligned, a strong vibration will be heard. If  the 
alignment is not corrected, this can cause increased electrical consumption, excessive wear 
on the components, excessive heat and excessive noise.

Protect the Pump From falling

Due to the nature of  the magnetically coupled design, it is possible for the VorTech to 
become dislodged from the aquarium glass and fall to the ground. The cord should be 
positioned vertically above the pump with the mounting tab directly above the motor to 
ensure that the motor does not move in the event of  a decoupling of  the magnets.

The provided cord-mounting tab MUST be used to prevent damage to the motor or the 

• 

surrounding environment.
The motor will shut down automatically if  either half  of  the pump is removed.

• 

Operational Modes

SlavePumpModes:

Sync

AntiͲSync

Mode

Set

Constant

Speed

Lagoon

Random

ReefͲCrest

Random

Pulse

speed

SinglePumpModeorMasterModes:

OperationalModes

Holdtoenter

andexit

FeedMode:

Pulse

frequency

Battery
Backup

Blinking

White

=HoldButton
=PressButton

ConfigurationMode

AssignPumpasSlave:

AssignPumpasMaster:

ClearSettings:

(Pump
Resets)

Cyclepowertopumpaftersettingmaster/slave

groupstocompleteprogramming

)