background image

2

3

Inside the Box

POWER SUPPLY

POWER CORD

FOAM GUARD

MOUNTING TABS (X4)

DRIVER

VELCRO STRIPS (X2)

DRY SIDE

ZIP TIES (X4)

RUBBER SPACER

WET SIDE

Your VorTech Propeller Pump is designed to  
operate optimally with little attention after initial 
setup; however, due to the harsh conditions of a 
saltwater aquarium and resulting buildup of algae 
and other organic matter, it is advisable to clean your 
wet side to ensure the longevity of your purchase.

EcoTech recommends doing a wet side cleaning 
every 6 to 8 weeks or as necessary.

This can be accomplished by disassembling the 
pump's wet side and gently brushing with a soft 
brush under running water. If there is calcium 
buildup, it may be necessary to soak these 
parts in a mild acid solution such as vinegar.  
Do not use strong acids, because these may 
damage the components.

After cleaning, reassemble the wet side. 

WET SIDE

DISASSEMBLY

WATCH THE VIDEO:

ecote.ch/mp10qddisassemble

Maintenance

Содержание VorTech MP10 EcoSmart

Страница 1: ...060117 Setup Guide MP10 MP10w ESL integration requires ReefLink...

Страница 2: ...ranty 19 Regulatory Information 20 1 Customer Support Many of the steps in this guide have corresponding how to videos View them on the EcoTech Marine website at ecotechmarine com media gallery video...

Страница 3: ...s advisable to clean your wet side to ensure the longevity of your purchase EcoTech recommends doing a wet side cleaning every 6 to 8 weeks or as necessary This can be accomplished by disassembling th...

Страница 4: ...Figure A STEP 4 Place Dry Side on Aquarium Place the rubber spacer directly on the wall of the aquarium at the desired location Figure B The included rubber spacer must be used between the dry side a...

Страница 5: ...ug the power supply into the driver If the pump is not already in Constant Speed Mode press the MODE button until the control dial is green If there is vibration or excessive noise carefully adjust th...

Страница 6: ...the control dial is not green check the power cable connections The driver is NOT water proof and water damage will NOT be covered under warranty 2 Plug the power supply into the driver and then plug...

Страница 7: ...1 LED bar will indicate change between modes Hold Feed Mode Hold Power Off Gyre Gyre Short Pulse Short Pulse Speed Set Speed Set Freq Set Freq Set Saved Saved Wave Wave Random Reef Crest Random Lagoon...

Страница 8: ...be set up to run together The colors in the diagrams above represent the flow pattern and placement of multiple pumps running together in a Master Slave relationship Master Slave relationships are on...

Страница 9: ...with the control dial and press the SET button to lock it The LEDs will begin to ramp indicating the pulsing frequency between 0 2 seconds and 2 seconds Next use the control dial to adjust the pulse...

Страница 10: ...y Backup accessory is added to the VorTech pump the pump will automatically switch to Battery Backup Mode during a power outage The pump will run at the minimum speed to maximize run time during this...

Страница 11: ...CABLE LAW NO IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY SHALL APPLY EXCEPT AS REQUIRED BY APPLICABLE LAW ECOTECH MARINE DOES NOT AUTHORIZE ANY PERSON OR BUSINESS ENTITY IN...

Страница 12: ...watts than the appliance rating may overheat Care should be taken to arrange the cord so that it will not be tripped over or pulled This appliance utilizes extremely powerful magnets that can cause se...

Отзывы: