LIGHTING THE FIRE AND RE-FUELING
-
ade.
applicable local regulations as well as these installation instructions.
een tested at nominal
output with a flue draught of 12 Pa) INITIAL CURING AND TEMPERING FIRES
ESSENTIAL INSTRUCTIONS BEFORE USE – It is essential to follow these ‘tempering-in’ instructions in
order to avoid serious damage to your stove. The castings of your stove require very gentle
‘normalising’ to release stresses in the metal formed during the casting process. The paint finish also
requires an initial curing process to be followed: -
For the initial tempering/ curing period, ensure the tertiary air inlet is set to MINIMUM, by pushing the
lever in. Set the Primary air to half position and secondary air to half position. For the first 2 burns on
day one just use small controlled kindling wood fires with each fire lasting around 40 minutes – the
second fire can be started when the stove is almost cooled down after the first. A third slightly hotter
medium type fire should then be lit using smallish logs and lasting around 1 hour. Then for the next
week or around 15-20 hours total burn time, fires must be gently increased in temperature and log size
and load. A stove thermometer will be a valuable tool in helping you to achieve this safely and also to
ensure an efficient burn rate in future. Starting a large fire too soon is likely to damage the stove in
which case it will not be covered by the warranty. Note: the paint on any new stove is relatively soft. As
such do not clean, wash or wipe the surface until the paint has fully cured. Never wipe the stove whilst
warm. If the above advice is ignored, then there is a high risk of the paint being “shocked” by excessive
heat and could peel. Furthermore, if the stove is over fired it will invalidate your guarantee.
ENSURE THAT YOU HAVE READ AND UNDERSTOOD THESE INSTRUCTIONS BEFORE LIGHTING THE FIRE,
AND THAT YOU ARE CONFIDENT THE STOVE HAS BEEN INSTALLED CORRECTLY.
ALWAYS WEAR A PROTECTIVE GLOVE WHEN REFUELLING YOUR STOVE.
Ignition (FOLLOW INITITAL TEMPERING INSTRUCTIONS ABOVE FIRST TO AVOID DAMAGE)
-pan is in place. Ensure all air inlets are fully open (tertiary air should be closed for first
3 burns)
fter about 5 minutes or when the fire is well established, shut the door
-5 minutes as the fire starts to die, add a further three larger pieces of wood
weighing approx. 0.75kg in total.
inutes or so, a normal load of 3 logs weighing up to
2.4kgs in total can be added.
condary and Tertiary
vents left open.