First use troubleshooting.
When the stove is new the paint is very tacky where the stove is curing. The door locks very
tight and when opened can pull away the fire rope from its chamber. If the instructions are
followed above this should not happen. However if it does the rope will need to be stuck back in
place with “heat resistant fire rope glue” After a few burns the paint will be cured and this
should no longer happen.
Refuelling
When re-fuelling the stove it was necessary to fully open both the primary and secondary air
controls for a period of 3 minutes to establish the fire before closing down to the minimum
output setting.
ll require refuelling approximately every hour.
d to maximise
the efficiency of the stove
harged logs
-establish the fire and follow
the “Ignition” procedure above.
n rates can be achieved by reducing the openings of the Secondary and Tertiary
air vents.
– If there is insufficient burning material in the firebed to light
a new fuel
charge, excessive smoke emission can occur. Refuelling must be carried out onto a sufficient
quantity of
glowing embers and ash that the new fuel charge will ignite in a reasonable period. If there are
too few embers in the fire bed, add suitable kindling to prevent excessive smoke.
Fuel overloading - The maximum amount of fuel specified in this manual should not be
exceeded, overloading can cause excess smoke.
Operation with door left open – Operation with the door open can cause excess smoke. The
appliance must not be operated with the door left open except as directed in the instructions.
The Ecosy+ 5 stove is suitable for use in smoke control areas when used in accordance with
these instructions.
WARNING
- The high temperature paint covering the stove will give off some fumes during the
initial few uses of the stove. The fumes are non-toxic, but some people may find them
unpleasant – Ensure the area is well ventilated during this period. The higher power output
rating of this stove is based on around 1.4kg of seasoned logs which would require refuelling
every hour.
This stove is suitable for intermittent burning, and should not be used constantly for extended
periods. Not suitable for overnight burning. Under certain abnormal weather conditions, e.g.