 1 | About the Device 

 
The device is designed to provide an efficient, comfortable, and healthy heating 
system for domestic or commercial properties.  

Infrared heating panels can reduce air circulation and help to maintain a clean, 
silent, dust free environment.  

Infrared panels are designed for indoor environments with normal heating 
requirements. They are ideal for homes, schools, hospitals and offices. They should 
not be used outdoors or in large internal spaces such as workshops or warehouses.  

The Ecostrad infrared panel range is available in a wide range of sizes and styles.  

 

2 | Warnings & Precautions  

 
Read this manual carefully before using or installing the device. Always store the 
manual in the immediate vicinity of the device or its site of use. 

Read all safety warnings and all instructions. 

Failure to follow the warnings and instructions may result in electric shock, fire, 
serious injury, or all of the above. Save all warnings and instructions for future 
reference.  

 

Warning

 

Do not ceiling mount panels designed for wall mounting only. 
Use of panels in unspecified locations can cause panels to overheat and 
poses a fire risk. 

 

Warning

 

This appliance can be used by children aged from 8 years and above and 
persons with reduced physical, sensory or mental capabilities or lack of 
experience and knowledge if they have been given supervision or instruction 
concerning the use of the appliance in a safe way and understand the 
hazards involved. Children shall not play with the appliance. Cleaning and 
user maintenance shall not be made by children without supervision. 

 

 

Warning

 

Children of less than 3 years should be kept away unless continuously 
supervised. Children aged from 3 years and less than 8 years shall only 
switch on/off the appliance provided that it has been placed or installed in 

Содержание F0606

Страница 1: ...1 Ecostrad Opus Infrared Heating Panel Ratings 220 240 V 50 Hz Class I IP54...

Страница 2: ...s clothes etc above or directly in front of the device To avoid overheating and fire hazards the device must not be covered Hot surface This symbol located on the device indicates that its surfaces ar...

Страница 3: ...1 About the Device 2 Warnings Precautions 3 Technical Information 4 Supplied Parts 5 Device Structure 6 Installation 7 Troubleshooting 8 Maintenance Servicing 9 Storage 10 ErP Ecodesign Information 1...

Страница 4: ...ilure to follow the warnings and instructions may result in electric shock fire serious injury or all of the above Save all warnings and instructions for future reference Warning Do not ceiling mount...

Страница 5: ...sitive skin and people under the influence of alcohol drugs or sleeping pills Remove both protective films on the front and on the back before using Be sure the usage voltage is between 220 240V 50Hz...

Страница 6: ...housing and pull Switch the device off and disconnect the power cable from the mains socket when the device is not in use Do not under any circumstances use the device if you detect damage to the main...

Страница 7: ...A Mounting Type F0606 595 x 595 350 230V 50Hz 1 5 Wall only F0706 705 x 605 450 2 0 Wall only F1006 1005 x 605 580 2 5 Wall only F1207 1205 x 755 900 3 9 Wall only F1209 1205 x 905 1100 4 8 Wall only...

Страница 8: ...nting kits are available through the supplier Kits are available for both direct and suspended installation Purchase a suitable kit before attempting ceiling mounted installation 5 Device Structure Co...

Страница 9: ...rrounding walls ceilings or fixed objects listed in the table opposite Minimum distances must be observed Mounting closer than recommended creates a fire risk 2 Stick the drilling template on the wall...

Страница 10: ...ct Method This method should only be used with panels designed for ceiling mounting when the kit below has been purchased Ecostrad Ceiling Mounting Kit 1 Drill four holes on the ceiling positioned as...

Страница 11: ...ws to the end tightly This is important for a secure fitting 3 Take off all four plastic caps from the mounting bars on the back of the panel Slide the panel onto the hanging brackets as per the diagr...

Страница 12: ...been purchased Ecostrad Suspended Mounting Kit Components 1 x Heating Panel A 4 x Panel Caps B 4 x Wire Caps C 4 x Ceiling Lock Screws D 4 x Ceiling Lock Heads E 4 x Long Screws F 4 x Short Screws G 4...

Страница 13: ...gh wire caps C Screw C onto B 3 Drill four 6mm holes in the ceiling using a 6mm drill bit Fix the four expansion plugs H into the holes 4 Insert the four long screws F into ceiling lock heads E and sc...

Страница 14: ...adjust the length of the suspension wire hold down the catch on the ceiling lock heads and feed the wire through the gap in the lock head Release the catch and the wire will lock automatically in you...

Страница 15: ...mperature Two possible causes 1 Voltage is too low 1 Contract an electrician to install a voltage regulator 2 The room where the panel is hung is very cold 2 This is normal Give the panel plenty of ti...

Страница 16: ...in an upright position out of direct sunlight Store in a dry environment protected from frost and heat Protect against dust using a cover if necessary To prevent damage do not store other objects on t...

Страница 17: ...lus week timer yes Other control options multiple selections possible room temperature control with presence detection no room temperature control with open window detection no with distance control o...