4.1.
Capacity Table
SQUARE BODY MONOBLOCK LIGHT OIL BURNERS CAPACITY TABLE
BURNER TYPE
CAPACITY
CAPACITY
LIGHT OIL
CONSUMPTION
FAN
MOTOR
POWER
MAIN SUPPLY
Min.
Kcal/h
Max.
Kcal/h
Min. kW
Max. kW
Min.
Kg/h
Max. Kg/h
kW
VAC
ONE STAGE LIGHT OIL BURNERS
ECO 1.0 OL C 1
10.200
35.700
12
42
1,0
3,5
0,15
1N 230
ECO 1.0 OL C 1 a
15.300
51.000
18
59
1,5
5,0
0,15
1N 230
ECO 1.0 OL C 1 b
20.400
71.400
24
83
2,0
7,0
0,15
1N 230
ECO 1.0 OL C 1 c
25.500
84.660
30
98
2,5
8,3
0,15
1N 230
ECO 2.0 OL C 1
59.976
132.600
70
154
5,9
13,0
0,15
1N 230
ECO 2.0 OL C 1a
71.400
173.400
83
202
7,0
17,0
0,15
1N 230
ECO 2.0 OL C 1b
81.600
214.200
95
249
8,0
21,0
0,25
1N 230
ECO 2.0 OL C 1c
107.100
265.200
125
308
10,5
26,0
0,25
1N 230
TWO STAGE LIGHT OIL BURNERS
ECO 2.0 OL C 2
59.976
132.600
70
154
5,9
13,0
0,15
1N 230
ECO 2.0 OL C 2a
71.400
173.400
83
202
7,0
17,0
0,15
1N 230
ECO 2.0 OL C 2b
81.600
214.200
95
249
8,0
21,0
0,25
1N 230
ECO 2.0 OL C 2c
107.100
265.200
125
308
10,5
26,0
0,25
1N 230
ECO 30.0 OL C 2
112.200
306.000
130
356
11
30
0,25
1N 230
ECO 30.0 OL C 2a
132.600
387.600
154
451
13
38
0,55
1N 230
ECO 30.0 OL C 2b
142.800
469.200
166
546
14
46
0,55
1N 230
ECO 30.0 OL C 2c
163.200
530.400
190
617
16
52
0,55
1N 230
H
u
Light Oil (L) = 10200 Kcal/kg
Содержание ECO 1.0
Страница 13: ...19 10 2018 Rev 07 12 4 2 Back Pressure Capacity Diagrams ...
Страница 14: ...19 10 2018 Rev 07 13 ...
Страница 15: ...19 10 2018 Rev 07 14 ...
Страница 22: ...19 10 2018 Rev 07 21 Ø One Stage Light Oil Burner Fuel Circuit Ø Two Stages Light Oil Burner Fuel Circuit ...
Страница 25: ...19 10 2018 Rev 07 24 7 8 Light Oil Burner Fuel Ring Line ...