Ecosmar+ XL700 Скачать руководство пользователя страница 4

© Copyright 2004 - 2010 The Fire Company Pty Ltd - International Patent Pending - Trademark Registered - All Designs Registered. 

www.ecosmartfire.com

Model Specifications

Burner Kit
XL700

4

7

Clearances

CONVERTING AN EXISTING FIREPLACE:

In order to keep the heat from escaping through the flue, place a panel of non-combustible heat reflective 

material such as stainless steel across your flue opening or utilise the damper within the existing fireplace 

setting to conserve heat.

 

All settings must incorporate a “Twin Skin”. If using the Top Tray that has been supplied with this model, the 

cut out dimensions are:-  

H 123mm [4.8] x W 680mm [26.7] x D 173mm [6.8].

Multiple burners may be installed into a fireplace setting however the ventilation requirements must be 

adhered to at all times. It is imperative that when installing multiple burners you consider strongly the impact 

of any accident and minimise it wherever possible. 

A fire extinguisher (AB:E type dry chemical extinguisher) is a compulsory accessory.

Installation Requirements

There are many different variations available for installing 

 

the EcoSmart™ XL700 Burner. In all cases, the EcoSmart™ 

 

XL700 Burner must:

- Be installed into non-combustible material ONLY 

 

– for example stainless steel, concrete, brick, stone

- Be fitted within a “Twin Skin”, such as the Top Tray included 

with this model from The Fire Company Pty Ltd so that there 

is a second barrier to capture any accidental spillage. If 

the Twin Skin is not supplied by The Fire Company Pty Ltd 

then it must undergo a “water tight” test prior to inserting the 

EcoSmart™ Burner into place

- All gas connections or pipelines near your EcoSmart™ 

installation must be disconnected and made safe by an 

appropriately qualified professional prior to installation

- Be installed into a fixed and secure position before filling, 

lighting and operating

- Be installed in a position that limits relocation requirements to 

eliminate the risk of accidents caused by fuel spillage – they 

are not designed to be relocated frequently

- Be installed into a level platform

- DO NOT INSTALL DIRECTLY BESIDE OR NEAR 

WALLPAPER, LAMINATE, VENEER OR ANY SURFACE 

THAT HAS NOT BEEN FIRE RATED (the heat will impact 

the material, and in some circumstances the glue used for its 

application). THIS INCLUDES THE DETAILING/FINISHING 

MATERIALS USED ON THE DECORATIVE SURFACES 

AROUND THE INSTALLED FIREBOX.

- Be installed into a setting that has a square back – the incorporation of angled backs alters the 

aerodynamics of the flame environment and could lead to an unstable flame behaviour

As a general guide we recommend that:

- Any furniture items or fittings directly above or beside the EcoSmart™ Fire installation be deemed 

suitable for heat tolerances by their manufacturer e.g Plasma Television Screens

- A heat reflective panel made of non combustible material (ideally stainless steel) be installed as the 

surround and top of the fireplace setting to assist in heat distribution

- Any reconstituted materials you wish to use be checked in terms of strength and suitability around such 

high temperature variations as some materials will crack – call The Fire Company Pty Ltd for more 

information about specific surfaces - Glass or mirrored surfaces near the EcoSmart™ Fire installation 

must be toughened

SPACERS: When the XL700 Burner is in position, there is usually an air gap around it. 

 

Do not pack with insulation or other materials, as the air spacers are required for ventilation. 

Cut Out

Top Tray

[26.7]

680mm

[6.8]

173mm

[4.8]

123mm

XL700 Burner

Содержание XL700

Страница 1: ... Copyright 2004 2010 The Fire Company Pty Ltd International Patent Pending Trademark Registered All Designs Registered www ecosmartfire com Burner Kit XL700 1 7 ...

Страница 2: ...nd easiest access for ignition 6 Top Tray The custom built Top Tray supplied with this model is made from Stainless Steel Grade 304 It is designed to sit underneath the burner without being seen from above The Top Tray is a compulsory accessory to guard against heat transference and to collect any accidental spillage 7 Spacers There are spacers fitted on all exterior panels and a spacer bar that s...

Страница 3: ...directly against any combustible materials and an air gap is incorporated for insulation around the box construction INSERTING WITHOUT A FIREBOX SETTING REAR A minimum of 40mm 1 6in space between the burner edge Top Tray edge and the rear wall which should be a non combustible material Warning The rear wall should be a non combustible material If the rear wall is combustible a distance of 600mm 23...

Страница 4: ...n must be disconnected and made safe by an appropriately qualified professional prior to installation Be installed into a fixed and secure position before filling lighting and operating Be installed in a position that limits relocation requirements to eliminate the risk of accidents caused by fuel spillage they are not designed to be relocated frequently Be installed into a level platform DO NOT I...

Страница 5: ...ution Do not install or operate in a bathroom or any other small room The room cannot be less than 100m3 3531ft3 per burner Efficiency The EcoSmart Fire is efficient because it is flueless which means all the heat stays in the room rather than most of it being flued outside as residual emissions You can turn the burner on and off as desired this allows you to control the amount of heat being gener...

Страница 6: ... VIEW 26 6 675 0 6 16 4 7 119 ISOMETRIC VIEW 27 6 700 SIDE VIEW 6 6 168 4 7 119 Scale 1 10 14 07 kg 31 03 lbs Material Stainless Steel Measurements inches imperial mm metric Weight 14 07kg 31 03lbs Materials Stainless Steel Scale 1 10 7 6 193 FRONT VIEW TOP VIEW 26 6 675 0 6 16 4 7 119 ISOMETRIC VIEW 27 6 700 SIDE VIEW 6 6 168 4 7 119 Scale 1 10 14 07 kg 31 03 lbs Material Stainless Steel ...

Страница 7: ...t Fires have not been tested with an unvented gas log set To reduce the risk of fire or injury do not install an unvented gas log set into this appliance 8 The EcoSmart Fire has not been tested for use with doors To reduce the risk of fire or injury do not install doors 9 It is recommended that the EcoSmart Fire be fixed into position to avoid displacement as per instruction provided with each mod...

Отзывы: