Avoid mounting the detector near heat sources, such as heating vents, air conditioning
units, light etc.
Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall
plants etc.
CONNECTION:
Warning. Danger of death through electric shock!
Must be installed by professional electrician,
Disconnect power source.
Cover or shied any adjacent live components.
Ensure device cannot be switched on.
Check power supply is disconnected.
Loosen the screw on the bottom and unload the bottom (refer to the figure1).
Pass the power wire through the hole with gasket in the bottom. Connect the power wire into
connection-wire column according to the connection-wire diagram.
Fix the bottom with inflated screw on the selected position (refer to the figure2).
Install back the sensor on the bottom, tighten the screw and then test it.
Figure1 Figure2
CONNECTION-WIRE DIAGRAM:
(See the right figure)
TEST:
Turn the LUX knob clockwise on
the maximum (sun); turn the TIME knob anti-clockwise on the minimum (-).
Switch on the power; the sensor and its connected lamp will have no signal at the
beginning. After Warm-up 30sec, the sensor can start work .If the sensor receives the
induction signal, the lamp will turn on. While there is no another induction signal any more,
the load should stop working within 10sec
±
3sec and the lamp would turn off..
Turn LUX knob anti-clockwise on the minimum (moon). If the ambient light is more than
3LUX, the inductor load should not work after the load stop working. If you cover the
detection window with the opaque objects (towel etc), the load would work .Under no
induction signal condition, the load should stop working within 10sec
±
3sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise
the sensor lamp could not work! If the lamp is more than 60W, the distance between lamp
and sensor should be 60cm at least.
SOME PROBLEM AND SOLVED WAY:
The load do not work:
a. Please check if the connection-wiring of power and load is correct.
b. Please check if the load is good.
c. Please check if the working light sets correspond to ambient light.
The sensitivity is poor:
a. Please check if there has any hindrance in front of the detection window to affect to
receive the signal.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection fields.
d. Please check if the installation height corresponds to the height showed in the
instruction.
e. Please check if the moving orientation is correct.
The sensor can not shut off the load automatically:
a. Please check if there is continual signal in the detection field.
b. Please check if the time delay is the longest.
c. Please check if the power corresponds to the instruction.