background image

 

Range 7030 

– 7032T 

Instruction manual

 

 

ECOSAFE | Date of the document : 22/03/2019– Version : 01 

 

The installation location must guarantee :  

 

That it is not exposed to any heat source 

 

That it is protected against moisture and that the ambient temperature of the location is neither less than 5°C, nor more than 

40°C 

 

Transport and handling 

 

The safety cabinet that you received has been protected and transported in optimal conditions, as to be protected from any damage.  

It has to be lifted only by suitable equipment (suction cup, 

strap…). It has to be carried in a vertical position, and it must not be lying.  

It is imperative not to tilt the cabinet when it is carried. Indeed it can cause damages that can alter the right functioning of the cabinet.  

On the other hand, if it has to be moved, the cabinet has to be placed on a pallet and strapped, as to avoid any fall.  

 

Commissioning 

 

After having unwrapped the cabinet, ensure that you also received a set of two keys.  

Your safety cabinet has to be installed, used and maintained as to guarantee the users protection.  

 

Swing doors 

The swinging doors can be open by pulling the handle. The automatic closing system allows the doors to be closed systematically after 

every use (if the blocking doors system is not activated).  

 

Door closing mechanism 

The door closing mechanism is adjusted in the warehouse, in usual conditions. In case of an important evolution of the temperature, its 

behaviour can evolve.  

If  the cabinet  has  been  delivered  during summer  or  winter, an  adaptation  period  to  the  ambient  temperature  might  be required.  This 

period can last up to 12 hours.  

 

Door blocking system 

The  door  blocking  system  allows  maintaining  the  doors  open,  during  an  undetermined  period.  It  allows  safe  manipulation  of  the 

chemicals.  

If the ambient temperature rises over 50°C, the opened door gets unlocked and will automatically close.  

It is mandatory for safety reasons, not to impede the proper closure of the doors with an object and to maintain the doors closed if the 

cabinet is not used.

 

4.  INTERNAL EQUIPMENTS 

 

The cabinet is provided with 1 containment sump.  

Take care not to exceed the loading capacity per containment sump of 50 KG. It has a retention capacity of 41 liters.  

 

 

Содержание 7030 Series

Страница 1: ...Range 7030 7032T Instruction manual ECOSAFE Date of the document 22 03 2019 Version 01 0 Instruction manual For safety cabinet Model 7032T ...

Страница 2: ... CONTENT 1 Description Use Page 2 2 Technical features Page 2 3 Installation and commissioning Page 2 4 Internal equipments Page 3 5 Storage Page 4 6 Ventilation Page 4 7 Safety controls Page 5 8 Spare parts Page 5 9 Recycling Page 6 10 Warranty Page 6 11 Control sheet for the user Page 7 ...

Страница 3: ...ing system Ventilation openings with a connecting sleeve diameter 100 mm for an eventual connection Ventilation ducts with a thermo fuse Thermo expanding door seals allowing to insulate the content of the safety cabinet in case of a fire If the temperature rises to 43 C the doors are closed automatically External dimensions H 635 x W 1115 x D 630 mm Storage capacity 60 liters Weight 108 KG 3 INSTA...

Страница 4: ...and maintained as to guarantee the users protection Swing doors The swinging doors can be open by pulling the handle The automatic closing system allows the doors to be closed systematically after every use if the blocking doors system is not activated Door closing mechanism The door closing mechanism is adjusted in the warehouse in usual conditions In case of an important evolution of the tempera...

Страница 5: ...ust not be used as a storage location neither be removed 6 VENTILATION First of all you need to remove the red covers which are positioned on the ventilation openings of the cabinet As to evacuate the vapors you need to connect the connecting sleeve which possesses the red arrow indicated OUT The air inlet possesses a green arrow indicated IN We highly recommend connecting your safety cabinet to a...

Страница 6: ...in a healthy fashion Filtration boxes are delivered with the activated carbon filter that you need to renew once a year Running without any mechanic ventilation It is possible for your safety cabinet to run without mechanical ventilation However your cabinet has to be placed in a location that provides its own ventilation system at least 5 times the volume of the location per hour The cabinet itse...

Страница 7: ...pictogram P N PICTOEN System to maintain the doors open Contact us Door closer mechanism Contact us Perforated cover plate P N C2T 9 RECYCLING The safety cabinet can be entirely dismounted Various elements such as the steel can be recycled Ensure to respect the national and local waste disposal terms Those elements should not be mixed with household waste 10 WARRANTY Your equipment holds a 12 mont...

Страница 8: ...hird party without any prior written authorization by ECOSAFE In case of a bad use of the equipment In case of a normal attrition of the equipment In case of a bad installation of the equipment In case of damage caused by the corrosion The activation of the warranty won t extend the term Our warranty stops if the customer has not notified us in a 7 days term after seeing the fault date that the cu...

Страница 9: ... of the doors works correctly The doors blocking system works correctly The mechanic ventilation system is running correctly if applicable The ventilation system is not obstructed The air inlet and outlet are clean The standardized pictogram on the door is in good condition and visible The door hinges are lubricated The locking system is lubricated The shelves and the containment sump are clean Th...

Отзывы: